Purpose Polymeric auxetic metamaterials have shown immense progress in their application as bioresorbable stents in the biomedical sector because of their superior mechanical and biocompatible properties. This paper aims to propose the implementation of novel hybrid auxetic structure in cylindrical stent prototypes. The proposed design is characterized by uniaxial tensile testing of standard specimens, axial and radial compression and three-point bending tests. The test outcomes made them suitable for stent fabrication in biomedical applications. Design/methodology/approach This research paper focuses on fabricating biodegradable hybrid auxetic tubes of transparent PLA and white PLA Pro+ by Fused Filament Fabrication (FFF). This novel polymeric hybrid auxetic tube (PHAT) design comprises re-entrant, hexagonal, meta-chiral auxetic unit cells. They are repeatedly arranged in a planar structure, rolled to form the cylindrical tube. Their deformation mechanisms are studied through experimental tests for stent applications. Findings The deformation pattern showcases half-wave and full-wave transformations on ligaments caused by anti-chiral and chiral circular nodes rotation, resulting in auxetic behavior due to Negative Poisson Ratio (NPR). The load displacement curves are plotted to evaluate axial, radial and bending stiffness as a measure of buckling resistance, crush resistance and bending flexibility to determine their suitability for stent applications. The axial foreshortening, radial recoil and dogboning rate are calculated to confirm their feasibility through the experimental test results. Originality/value The NPR values attained are −2.25 and −3.43 for transparent and white PLA Pro+ specimens, respectively. The axial stiffness of 166.18 N/mm and 105.96 N/mm, radial stiffness of 33.75 N/mm and 28.86 N/mm, bending stiffness value of 14.31 N.mm2 and 18.89 N.mm2 and bending flexibility of 69.93 × 10–3 1/N.mm2 and 52.94 × 10–3 1/N.mm2 are found for transparent PLA and white PLA Pro+, respectively. The foreshortening effects of 0.57% and 0.64%, radial recoil of 4.12% and 3.64% and dogboning effects of 9.67% and 10.56% are observed from experimental results.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Cellular and Composite Structures · Advanced Materials and Mechanics · Automotive and Human Injury Biomechanics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

National Institute of Technology Department of Production Engineering, , Tiruchirappalli,

References (72)

Show source-provided references
1. Novel hybrid 3D-printed auxetic vascular stent based on re-entrant and meta-trichiral unit cells: finite element simulation with experimental verifications10.1016/j.mtcomm.2023.105742 ↗
2. Evaluation of coronary stents: a review of types, materials, processing techniques, design, and problems10.1016/j.heliyon.2023.e13575 ↗
3. A review based on biodegradable and bioabsorbable stents for coronary artery disease10.1016/j.procs.2019.05.006 ↗
4. 3D printed auxetic stents with re-entrant and chiral topologies10.1088/1361-665x/ad026d ↗
5. From 3D models to FDM 3D prints: experimental study of chemical treatment to reduce stairs-stepping of semi-sphere profile10.3934/matersci.2019.6.1086 ↗
6. Auxetic coronary stent endoprosthesis: fabrication and structural analysis10.5301/jabfm.5000213 ↗
7. Characterisation of process-induced defects in polymeric strut-based lattice structures produced by powder bed fusion additive manufacturing process10.2139/ssrn.4719350 ↗
8. ASTM International · 2020
9. ASTM International · 2022
10. ASTM International · 2022
11. Modelling of hexagonal honeycombs exhibiting zero Poisson’s ratio10.1002/pssb.201083980 ↗
12. Analytical and numerical solution for auxetic stent with Re-entrant geometry and its multi-objective optimization10.22044/JSFM.2023.12193 ↗
13. Analytical and numerical solution and multi-objective optimization of tetra-star-chiral auxetic stents10.1007/s42452-024-05663-1 ↗
14. Influence of negative poisson′s ratio on stent applications10.11648/j.am.20130203.14 ↗
15. Understanding the requirements of self-expandable stents for heart valve replacement: radial force, hoop force and equilibrium10.1016/j.jmbbm.2017.02.006 ↗
16. 3D printed polymeric stent design: mechanical testing and computational modeling10.1016/j.matdes.2024.113395 ↗
17. Deformation behaviour of self-expanding magnesium stents based on auxetic chiral lattices10.1016/j.ctmat.2016.01.002 ↗
18. Effective elastic modulus and energy absorption performance evaluations of a novel re-entrant chiral hybrid honeycomb10.1007/s10483-025-3246-9 ↗
19. Auxetic polymers: a new range of materials10.1016/0160-9327(91)90123-s ↗
20. Novel cardiovascular stent based on Hibiscus-Aestivation-Inspired auxetic unit cell10.1016/j.ijmecsci.2024.109428 ↗
21. 3D-Printed PCL/PLA composite stents: towards a new solution to cardiovascular problems10.3390/ma11091679 ↗
22. A novel double arrowhead auxetic coronary stent10.1016/j.compbiomed.2023.107525 ↗
23. 2D triangular anti-trichiral structures and auxetic stents with symmetric shrinkage behavior and high energy absorption10.1016/j.mechmat.2019.103291 ↗
24. Understanding atherosclerosis pathophysiology: can additive manufacturing Be helpful?10.3390/polym15030480 ↗
25. Biodegradable stents for coronary artery disease treatment: recent advances and future perspectives10.1016/j.msec.2018.04.100 ↗
26. Study on the size effect of auxetic cellular materials10.1515/ijame-2017-0047 ↗
27. Crystallization and biocompatibility enhancement of 3D-printed poly(l-lactide) vascular stents with long chain branching structures10.1039/c9ce01477b ↗
28. Additive manufacturing for surgical planning and education: a review10.3390/app14062550 ↗
29. The road to the ideal stent: a review of stent design optimisation methods, findings, and opportunities10.1016/j.matdes.2023.112556 ↗
30. Investigation of HA nanocrystallite size crystallographic characterizations in NHA, BHA and HA pure powders and their influence on biodegradation of HA10.4028/www.scientific.net/amr.829.314 ↗
31. 3D printed stents using fused deposition modelling10.1016/j.jddst.2024.105724 ↗
32. Finite element simulation and testing of cobalt-chromium stent: a parametric study on radial strength, recoil, foreshortening, and dogboning10.1080/10255842.2020.1822823 ↗
33. Investigation into tensile behavior of 3D printed nylon-based low and high-volume fraction carbon fiber composite10.1108/rpj-06-2022-0204 ↗
34. In plane mechanical properties of tetrachiral and antitetrachiral hybrid metastructures10.1115/1.4036937 ↗
35. A flexible porous chiral auxetic tracheal stent with ciliated epithelium10.1016/j.actbio.2021.01.044 ↗
36. Numerical study of a re-entrant diamond structure under dynamic compression10.1088/1757-899x/1067/1/012109 ↗
37. Bio-resorbable polymer stents: a review of material progress and prospects10.1016/j.progpolymsci.2018.05.002 ↗
38. Mechanical properties of CF-reinforced PLA parts manufactured by fused deposition modeling10.1177/0892705719847244 ↗
39. Comparison of femoropopliteal artery stents under axial and radial compression, axial tension, bending, and torsion deformations10.1016/j.jmbbm.2017.07.017 ↗
40. Effective elastic properties of periodic hexagonal honeycombs10.1016/j.mechmat.2015.07.008 ↗
41. Novel hybrid auxetic structures for improved in- plane mechanical properties via additive manufacturing10.1016/j.mechmat.2021.103890 ↗
42. On the suitability of hexagonal honeycombs as stent geometries10.1002/pssb.201384255 ↗
43. Effects of stent structure on stent flexibility measurements10.1007/s10439-005-2807-6 ↗
44. Determination of thermodynamic parameters of polylactic acid by thermogravimetry under pyrolysis conditions10.3390/app112110192 ↗
45. Structural design of vascular stents: a review10.3390/mi12070770 ↗
46. Mechanical properties of foam-filled auxetic circular tubes: experimental and numerical study10.1016/j.tws.2021.108584 ↗
47. Chiral constrained stent: effect of structural design on the mechanical and intravascular stent deployment performances10.1016/j.mechmat.2020.103509 ↗
48. Mechanical design of Antichiral-Reentrant hybrid intravascular stent10.1142/s1758825118501053 ↗
49. A comparison of the mechanical performance characteristics of seven drug-eluting stent systems10.1002/ccd.21832 ↗
50. Synthesis, properties, environmental degradation, processing, and applications of polylactic acid (PLA): an overview10.1007/s00289-024-05252-7 ↗
51. 3D printing of polymeric bioresorbable stents: a strategy to improve both cellular compatibility and mechanical properties10.3390/polym14061099 ↗
52. Exploiting nonlinearities through geometric engineering to enhance the auxetic behaviour in re-entrant honeycomb metamaterials10.1038/s41598-023-47525-7 ↗
53. Melting temperature and enthalpy variations of phase change materials (PCMs): a differential scanning calorimetry (DSC) analysis10.1080/01411594.2018.1469019 ↗
54. Achieving high mechanical properties of biodegradable vascular stents by Four-Axis 3d printing system and heat treatment10.1016/j.matlet.2023.134261 ↗
55. Re-entrant auxetic structures fabricated by fused deposition modeling: an experimental study of influence of process parameters under compressive loading10.1002/pen.25546 ↗
56. Numerical and experimental investigation of FDM fabricated re-entrant auxetic structures of ABS and PLA materials under compressive loading10.1108/rpj-10-2019-0271 ↗
57. Vyavahare · 2020 · 305
58. FDM manufactured auxetic structures: an investigation of mechanical properties using machine learning techniques10.1016/j.ijsolstr.2023.112126 ↗
59. Additively manufactured meta-biomaterials: a state-of-the-art review10.1016/j.compstruct.2022.116491 ↗
60. Fused deposition modelling: a review10.1108/rpj-04-2019-0106 ↗
61. Design, characterization, and 3D printing of cardiovascular stents with zero Poisson’s ratio in longitudinal deformation10.1016/j.eng.2020.02.013 ↗
62. The development of design and manufacture techniques for bioresorbable coronary artery stents10.3390/mi12080990 ↗
63. Computational and experimental investigation into mechanical performances of Poly-L-Lactide acid (PLLA) coronary stents10.1016/j.jmbbm.2016.08.033 ↗
64. Mechanical design and multifunctional applications of chiral mechanical metamaterials: a review10.1016/j.matdes.2019.107950 ↗
65. Mechanical properties of anti-tetrachiral auxetic stents10.1016/j.compstruct.2017.11.048 ↗
66. Radial compressive property and the proof-of-concept study for realizing self-expansion of 3D printing polylactic acid vascular stents with negative Poisson’s ratio structure10.3390/ma11081357 ↗
67. Dynamic local and global buckling of cylindrical shells under axial impact10.1016/j.engstruct.2009.01.009 ↗
68. Design of Self-Expanding auxetic stents using topology optimization10.3389/fbioe.2020.00736 ↗
69. Advancing toward 3D printing of bioresorbable shape memory polymer stents10.1021/acs.biomac.0c01082 ↗
70. Determination of the influence of stent strut thickness using the finite element method: implications for vascular injury and in-stent restenosis10.1007/s11517-009-0432-5 ↗
71. Conceptual design and analysis of novel hybrid auxetic stents with superior expansion10.1016/j.mechmat.2023.104813 ↗
72. Effects of chemical and morphological structure on biodegradability of fibers, fabrics, and other polymeric materials10.15376/biores.15.4.zambrano ↗