Abstract Bridging nerve gaps by means of autologous nerve grafts involves donor nerve graft harvesting. Recent studies have focused on the use of alternative methods, and one of these is the use of biodegradable nerve guides. After serving their function, nerve guides should degrade to avoid a chronic foreign body reaction. The in vitro degradation, in vitro cytotoxicity, hemocompatibility, and short‐term in vivo foreign body reaction of poly(65/35 (85/15L/D) lactide‐ϵ‐caprolactone) nerve guides was studied. The in vitro degradation characteristics of poly(DLLA‐ϵ‐CL) nerve guides were monitored at 2‐week time intervals during a period of 22 weeks. Weight loss, degree of swelling of the tube wall, mechanical strength, thermal properties, and the intrinsic viscosity of the nerve guides were determined. Cytotoxicity was studied by measuring the cell proliferation inhibition index (CPII) on mouse fibroblasts in vitro. Cell growth was evaluated by cell counting, while morphology was assessed by light microscopy. Hemocompatibility was evaluated using a thrombin generation assay and a complement convertase assay. The foreign body reaction against poly(DLLA‐ϵ‐CL) nerve guides was investigated by examining toluidine blue stained sections. The in vitro degradation data showed that poly(DLLA‐ϵ‐CL) nerve guides do not swell, maintain their mechanical strength and flexibility for a period of about 8–10 weeks, and start to lose mass after about 10 weeks. Poly(DLLA‐ϵ‐CL) nerve guides were classified as noncytotoxic, as cytotoxicity tests demonstrated that cell morphology was not affected (CPII 0%). The thrombin generation assay and complement convertase assay indicated that the material is highly hemocompatible. The foreign body reaction against the biomaterial was mild with a light priming of the immunesystem. The results presented in this study demonstrate that poly(65/35 (85/15L/D) lactide‐ϵ‐caprolactone) nerve guides are biocompatible, and show good in vitro degradation characteristics, making these biodegradable nerve guides promising candidates for bridging peripheral nerve defects up to several centimeters. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res 68A: 43–51, 2004
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Electrospun Nanofibers in Biomedical Applications · Nerve injury and regeneration · Polymer Surface Interaction Studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (40)
Show source-provided references
1. 10.1523/JNEUROSCI.15-05-04109.199510.1523/JNEUROSCI.15-05-04109.1995 ↗
2. 10.1016/0267-6605(92)90100-810.1016/0267-6605(92)90100-8 ↗
3. Een afbreekbare kunststof zenuwgeleider voor de overbrugging van perifere zenuwdefecten [A biodegradable nerve conduit for bridging peripheral nerve defects]
4. 10.1055/s-2002-1988910.1055/s-2002-19889 ↗
5. 10.1016/0006-8993(84)91014-X10.1016/0006-8993(84)91014-X ↗
6. 10.1055/s-2007-100660410.1055/s-2007-1006604 ↗
7. 10.1097/00006534-198912000-0001310.1097/00006534-198912000-00013 ↗
8. 10.1007/BF0180927210.1007/BF01809272 ↗
9. 10.1177/0022034584063007160110.1177/00220345840630071601 ↗
10. Growth factors and extra cellular matrix in peripheral nerve regeneration, studied with a nerve chamber
11. Peripheral nerve regeneration through bioresorbable and durable nerve guides
12. Peripheral nerve repair with bioresorbable prosthesis
13. 10.1002/mus.88005011010.1002/mus.880050110 ↗
14. 10.1002/micr.192010021310.1002/micr.1920100213 ↗
15. 10.3171/jns.1968.28.6.058210.3171/jns.1968.28.6.0582 ↗
16. 10.1007/BF0031690210.1007/BF00316902 ↗
17. 10.1007/BF0012013310.1007/BF00120133 ↗
18. 10.1002/micr.192014080810.1002/micr.1920140808 ↗
19. CordewenerFW.The potential of poly(96L/4D‐lactide) as a biodegradable osteosynthesis material. Thesis Groningen The Netherlands 1996.
20. 10.1002/jbm.82029061210.1002/jbm.820290612 ↗
21. 10.1002/(SICI)1097-4636(199605)31:1<105::AID-JBM13>3.0.CO;2-M10.1002/(SICI)1097-4636(199605)31:1<105::AID-JBM13>3.0.CO;2-M ↗
22. 10.1002/(SICI)1098-2752(1996)17:7<348::AID-MICR2>3.0.CO;2-C10.1002/(SICI)1098-2752(1996)17:7<348::AID-MICR2>3.0.CO;2-C ↗
23. 10.1002/mus.106610.1002/mus.1066 ↗
24. 10.1002/(SICI)1097-4636(19970905)36:3<337::AID-JBM9>3.0.CO;2-F10.1002/(SICI)1097-4636(19970905)36:3<337::AID-JBM9>3.0.CO;2-F ↗
25. Peripheral nerve regeneration and functional nerve recovery after reconstruction with a thin‐walled biodegradable poly(DL‐lactide‐ϵ‐caprolactone) nerve guide
26. ISO10993‐1:1997(E) Biological evaluation of medical devices‐part 1: Evaluation and testing.Geneva:International Organisation of Standardisation;1997.
27. Biological evaluation of medical devices‐part 5: Tests for cytotoxicity: In vitro methods ISO/DIS 10993‐5(EN 30993‐5).Geneva:International Organisation of Standardisation;1992.
28. 10.1046/j.1525-1594.2002.06872.x10.1046/j.1525-1594.2002.06872.x ↗
29. Grijpma DW · 1993
30. 10.1016/0014-3057(72)90109-710.1016/0014-3057(72)90109-7 ↗
31. 10.1002/1097-4636(20000915)51:4<575::AID-JBM5>3.0.CO;2-Z10.1002/1097-4636(20000915)51:4<575::AID-JBM5>3.0.CO;2-Z ↗
32. 10.1016/0142-9612(81)90060-010.1016/0142-9612(81)90060-0 ↗
33. 10.1002/(SICI)1097-4636(19981215)42:4<475::AID-JBM1>3.0.CO;2-B10.1002/(SICI)1097-4636(19981215)42:4<475::AID-JBM1>3.0.CO;2-B ↗
34. 10.1016/S0141-3910(97)00183-310.1016/S0141-3910(97)00183-3 ↗
35. 10.1002/app.1981.07026112410.1002/app.1981.070261124 ↗
36. In vitro degradation of poly(DL‐lactide‐ϵ‐caprolactone) nerve guides
37. Biocompatibility: Complement as mediator of tissue damage and as indicator of incompatibility
38. 10.1111/j.1600-6143.2006.01653.x10.1111/j.1600-6143.2006.01653.x ↗
39. 10.1182/blood.V98.4.123110.1182/blood.V98.4.1231 ↗
40. 10.1007/BF0070124010.1007/BF00701240 ↗