Abstract Nanoscale topography in improving vascular response in vitro was established previously on various titanium surfaces. In the present study different surface nanotopographies that is different diameters of titanium dioxide (TiO2) nanotubes (NTs) were fabricated by electrochemical anodization and conditioned with highly reactive gaseous oxygen plasma. The morphology of different diameter NTs was studied by scanning electron microscopy and atomic force microscopy, while changes in chemical composition on the surface before and after plasma treatment were determined by X‐ray photoelectron spectroscopy. Performance of human coronary artery endothelial cells (HCAEC) on those conditioned surfaces was studied in regard to cell proliferation, released IL‐6 protein and immunofluorescence microscopy (IFM). We show that HCAEC function is dependent on the diameter of the TiO2 NTs, functioning far less optimally when bound to 100 nm TiO2 NTs as compared to Ti foil, 15 nm NTs or 50 nm NTs. There were improved, morphological cell shape changes, observed with IFM, between HCAEC growing on oxygen‐rich plasma‐treated versus nontreated 100 nm NTs. These endothelialized conditioned Ti nanosurfaces could elucidate optimization conditions necessary for vascular implants in coronary arteries. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 104A: 1113–1120, 2016.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Nanoparticles: synthesis and applications · Anodic Oxide Films and Nanostructures · TiO2 Photocatalysis and Solar Cells

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Laboratory of Biophysics, Faculty of Electrical Engineering University of Ljubljana Ljubljana SI‐1000 Slovenia

Department of Rheumatology University Medical Centre Ljubljana Ljubljana SI‐1000 Slovenia

Josef Stefan Institute, Jamova 39 Ljubljana 1000 Slovenia

Faculty of Pharmacy Chair for Clinical Biochemistry, University of Ljubljana Ljubljana SI‐1000 Slovenia

Department of Materials Science and Engineering WW4‐LKO, University of Erlangen Nuremberg Martensstr, 7 91058 Erlangen Germany

Faculty of Mathematics, Natural Science and Information Technologies University of Primorska Koper SI‐6000 Slovenia

Funding

Slovenian Research Agency (ARRS) · EU supported grant

References (27)

Show source-provided references
1. 10.1007/s10047-008-0456-x10.1007/s10047-008-0456-x ↗
2. 10.2310/6620.2011.1005510.2310/6620.2011.10055 ↗
3. Biomaterial surface modification of titanium and titanium alloys for medical applications
4. 10.1002/anie.20100137410.1002/anie.201001374 ↗
5. 10.1088/0957-4484/26/6/06200210.1088/0957-4484/26/6/062002 ↗
6. Binding of plasma proteins to titanium dioxide nanotubes with different diameters
7. 10.1016/j.jcin.2009.04.01710.1016/j.jcin.2009.04.017 ↗
8. 10.1039/C1JM13726C10.1039/C1JM13726C ↗
9. Enhanced endothelial cell functions on rosette nanotube‐coated titanium vascular stents
10. 10.1016/j.biomaterials.2008.11.01210.1016/j.biomaterials.2008.11.012 ↗
11. 10.1021/nl072572o10.1021/nl072572o ↗
12. 10.1016/j.apsusc.2004.05.13410.1016/j.apsusc.2004.05.134 ↗
13. 10.1016/S0142-9612(98)00212-910.1016/S0142-9612(98)00212-9 ↗
14. 10.1161/hc3401.09314610.1161/hc3401.093146 ↗
15. 10.1002/(SICI)1097-4636(199810)42:1<128::AID-JBM16>3.0.CO;2-H10.1002/(SICI)1097-4636(199810)42:1<128::AID-JBM16>3.0.CO;2-H ↗
16. Intravascular stents in the last and the next 10 years10.1177/15266028040110S621 ↗
17. Surface modification of biomaterials: A quest for blood compatibility
18. 10.1039/b703416b10.1039/b703416b ↗
19. 10.1016/j.nantod.2013.04.01010.1016/j.nantod.2013.04.010 ↗
20. 10.1021/cr500061m10.1021/cr500061m ↗
21. 10.1177/1721727X070050020310.1177/1721727X0700500203 ↗
22. 10.1155/2009/14687210.1155/2009/146872 ↗
23. 10.1016/j.mvr.2013.07.01110.1016/j.mvr.2013.07.011 ↗
24. 10.1021/jp075258r10.1021/jp075258r ↗
25. 10.1016/j.vacuum.2005.11.07310.1016/j.vacuum.2005.11.073 ↗
26. 10.1093/intimm/dxq03010.1093/intimm/dxq030 ↗
27. 10.1038/ni.315310.1038/ni.3153 ↗