journal article·2007-02

Histological assessment of titanium and polypropylene fiber mesh implantation with and without fibrin tissue glue

E.J. Olivier ten Hallers, John A. Jansen, Henri A.M. Marres, Gerhard Rakhorst, Gijsbertus J. Verkerke

Publisher page

Abstract

Abstract Polypropylene (PP) and titanium (Ti) meshes are well‐known surgical implants that provoke a relative low foreign body reaction. Firm stabilization of the implant is important to prevent migration and subsequent failure of the operation. Fibrin tissue glues are commercially available adhesives and are widely accepted and applied in the medical field for hemorrhage, surgical bleeding, support of wound healing, wound and tissue gluing, sealing, and closure but also as antiadhesive agent in certain applications. The objective of this study was to evaluate the additional histological effect of fibrin glue application combined with two different types of meshes. Six pieces of mesh of each were subcutaneously implanted for 3, 6, and 12 weeks, with and without fibrin glue. After excision, processing, and staining, light microscopic analysis was performed on the sections, using subjective histological description and histomorphometry. Capsule quality, capsule thickness, interstitial quality, and total score were evaluated. To compare the samples with glue and without glue, analysis of variance (ANOVA) tests were carried out. No complications were observed. In general, the glue remnants remained visible at 3 and 6 weeks of implantation, accompanied by an inflammatory reaction and macrophage activity. At 12 weeks, all samples showed good tissue integration without evidence of glue. Evidently, the samples with glue demonstrated a prolonged inflammatory response and were surrounded by fibrous tissue capsules that were significantly thicker compared with the samples without glue (p < 0.05). © 2006 Wiley Periodicals, Inc. J Biomed Mater Res, 2007
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Hemostasis and retained surgical items · Surgical Sutures and Adhesives · Reconstructive Surgery and Microvascular Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (31)

Show source-provided references
1. 10.1007/s00268990028210.1007/s002689900282 ↗
2. 10.1007/s00464-003-8113-110.1007/s00464-003-8113-1 ↗
3. 10.1007/s10029-005-0334-x10.1007/s10029-005-0334-x ↗
4. 10.1023/A:100884002201610.1023/A:1008840022016 ↗
5. 10.1016/S0142-9612(00)00317-310.1016/S0142-9612(00)00317-3 ↗
6. 10.1016/S0142-9612(99)00102-710.1016/S0142-9612(99)00102-7 ↗
7. A new titanium fiber mesh‐cuffed peritoneal dialysis catheter: Evaluation and comparison with a Dacron‐cuffed tenckhoff catheter in goats10.1177/089686080102100305 ↗
8. Octylcyanoacrylate tissue adhesive as an alternative to mechanical fixation of expanded polytetrafluoroethylene prosthesis10.1177/000313480106701013 ↗
9. 10.1097/00000658-200101000-0000410.1097/00000658-200101000-00004 ↗
10. 10.1097/00006123-200109000-0004310.1097/00006123-200109000-00043 ↗
11. 10.1053/ajot.2001.2481710.1053/ajot.2001.24817 ↗
12. Fibrin sealant use for minimising peri‐operative allogeneic blood transfusion
13. Experimental study on bacterial colonization of fibrin glue and its prevention
14. 10.1002/(SICI)1097-4636(19980305)39:3<462::AID-JBM17>3.0.CO;2-C10.1002/(SICI)1097-4636(19980305)39:3<462::AID-JBM17>3.0.CO;2-C ↗
15. 10.1016/S0002-9610(01)00771-110.1016/S0002-9610(01)00771-1 ↗
16. 10.1016/S0002-9610(01)00770-X10.1016/S0002-9610(01)00770-X ↗
17. 10.1016/S0002-9610(01)00775-910.1016/S0002-9610(01)00775-9 ↗
18. Comparison of the bonding power of various autologous fibrin tissue adhesives
19. 10.1016/S0002-9610(01)00742-510.1016/S0002-9610(01)00742-5 ↗
20. 10.1080/08941930175042026910.1080/089419301750420269 ↗
21. 10.1016/S0002-9610(01)00774-710.1016/S0002-9610(01)00774-7 ↗
22. 10.1016/0142-9612(96)84946-510.1016/0142-9612(96)84946-5 ↗
23. 10.1002/jbm.82028111010.1002/jbm.820281110 ↗
24. 10.1002/jab.77005041310.1002/jab.770050413 ↗
25. 10.1177/08853282940090010210.1177/088532829400900102 ↗
26. 10.1016/S0142-9612(96)00090-710.1016/S0142-9612(96)00090-7 ↗
27. 10.1007/s10029-004-0292-810.1007/s10029-004-0292-8 ↗
28. 10.1002/bjs.445110.1002/bjs.4451 ↗
29. 10.1016/j.biomaterials.2004.02.07010.1016/j.biomaterials.2004.02.070 ↗
30. 10.1016/S0142-9612(00)00390-210.1016/S0142-9612(00)00390-2 ↗
31. 10.1002/1097-4636(200010)52:1<231::AID-JBM29>3.0.CO;2-E10.1002/1097-4636(200010)52:1<231::AID-JBM29>3.0.CO;2-E ↗