Adhesion of staphylococcal and Caco‐2 cells on diamond‐like carbon polymer hybrid coating
Source abstract
Abstract
Abstract Staphylococci cause the majority of the nosocomial implant‐related infections initiated by adhesion of planktonic bacteria to the implant surface. It was hypothesized that plasma accelerating filtered pulsed arc discharge method enables combination of the advantageous properties of diamond with the antisoiling properties of polymers. Diamond‐like carbon polytetrafluoroethylene hybrid (DLC‐PTFE‐h) coating was produced. The adhesion of S. aureus ATCC 25923 (108 colony‐forming units/mL) to surfaces diminished from 2.32%, 2.35%, and 2.57% of high quality DLC, titanium, and oxidized silicon, respectively, to 1.93% of DLC‐PTFE‐h. For S. epidermidis ATCC 35984 the corresponding figures were 3.90%, 3.32%, 3.47%, and 2.57%. Differences in bacterial adhesion between recombinant DLC‐PTFE‐h and other materials were statistically significant (p < 0.05). In contrast, human Caco‐2 cells adhered as well to DLC‐PTFE‐h as to DLC, titanium, or silicon, which were all in the MTT test found to be cytocompatible. DLC‐PTFE‐h coating can be used to modify the surface properties of any surgical implants and is an unfavorable substrate for staphylococcal cells, but compatible with human Caco‐2 cells. DLC‐PTFE‐h coating may help in the combat against Staphylococcus‐related implant infections which usually require both antibiotics and surgical removal of the implant for cure. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res 2008
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Diamond and Carbon-based Materials Research · Metal and Thin Film Mechanics · Orthopedic Infections and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (32)
Show source-provided references
1. 10.1086/32313010.1086/323130 ↗
2. 10.1056/NEJMra04018110.1056/NEJMra040181 ↗
3. The development of implants and implantable materials10.1016/S0030-6665(20)30537-5 ↗
4. 10.1002/(SICI)1097-4636(199823)43:3<338::AID-JBM16>3.0.CO;2-B10.1002/(SICI)1097-4636(199823)43:3<338::AID-JBM16>3.0.CO;2-B ↗
5. 10.1086/32297210.1086/322972 ↗
6. 10.1128/978155581806710.1128/9781555818067 ↗
7. 10.1007/BF0070534710.1007/BF00705347 ↗
8. 10.1166/jnn.2006.42410.1166/jnn.2006.424 ↗
9. 10.1016/j.bcp.2006.01.01210.1016/j.bcp.2006.01.012 ↗
10. 10.1007/s10856-006-0612-x10.1007/s10856-006-0612-x ↗
11. 10.1126/science.362925810.1126/science.3629258 ↗
12. 10.1016/0167-577X(95)00071-210.1016/0167-577X(95)00071-2 ↗
13. 10.1002/adma.1997009150710.1002/adma.19970091507 ↗
14. 10.1016/S0925-9635(03)00238-310.1016/S0925-9635(03)00238-3 ↗
15. 10.1016/S0927-796X(02)00005-010.1016/S0927-796X(02)00005-0 ↗
16. 10.1179/02670840322500619510.1179/026708403225006195 ↗
17. 10.1016/j.matlet.2004.01.02410.1016/j.matlet.2004.01.024 ↗
18. AnttilaA HirvonenJ‐P KoskinenJ. Procedure and apparatus for the coating of materials by means of a pulsating plasma beam. US Patent No. 5 078 848 1992.
19. 10.1016/j.diamond.2006.02.00210.1016/j.diamond.2006.02.002 ↗
20. 10.1097/01.mao.0000169767.85549.8710.1097/01.mao.0000169767.85549.87 ↗
21. 10.1093/ejo/cji09410.1093/ejo/cji094 ↗
22. 10.1016/0022-1759(83)90303-410.1016/0022-1759(83)90303-4 ↗
23. Hemocompatibility of diamond‐like carbon coating
24. 10.1002/jbm.a.3006610.1002/jbm.a.30066 ↗
25. 10.1023/B:JMSM.0000021123.51752.1110.1023/B:JMSM.0000021123.51752.11 ↗
26. 10.1016/S0142-9612(01)00182-X10.1016/S0142-9612(01)00182-X ↗
27. 10.1016/j.diamond.2003.10.06410.1016/j.diamond.2003.10.064 ↗
28. 10.1016/S0040-6090(97)00422-710.1016/S0040-6090(97)00422-7 ↗
29. 10.1016/0267-6605(94)90041-810.1016/0267-6605(94)90041-8 ↗
30. 10.1002/1097-4636(2001)58:3<319::AID-JBM1024>3.0.CO;2-F10.1002/1097-4636(2001)58:3<319::AID-JBM1024>3.0.CO;2-F ↗
31. 10.1016/0142-9612(96)81418-910.1016/0142-9612(96)81418-9 ↗
32. 10.1016/0142-9612(96)89777-810.1016/0142-9612(96)89777-8 ↗