Mesenchymal stem cell adhesion and spreading on microwave plasma‐nitrided titanium alloy
Source abstract
Abstract
Abstract Improved methods to increase surface hardness of metallic biomedical implants are being developed in an effort to minimize the formation of wear debris particles that cause local pain and inflammation. However, for many implant surface treatments, there is a risk of film delamination due to the mismatch of mechanical properties between the hard surface and the softer underlying metal. In this article, we describe the surface modification of titanium alloy (Ti‐6Al‐4V), using microwave plasma chemical vapor deposition to induce titanium nitride formation by nitrogen diffusion. The result is a gradual transition from a titanium nitride surface to the bulk titanium alloy, without a sharp interface that could otherwise lead to delamination. We demonstrate that vitronectin adsorption, as well as the adhesion and spreading of human mesenchymal stem cells to plasma‐nitrided titanium is equivalent to that of Ti‐6Al‐4V, while hardness is improved 3‐ to 4‐fold. These in vitro results suggest that the plasma nitriding technique has the potential to reduce wear, and the resulting debris particle release, of biomedical implants without compromising osseointegration; thus, minimizing the possibility of implant loosening over time. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res, 2006
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty · Metal and Thin Film Mechanics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (39)
Show source-provided references
1. 10.1016/S0142-9612(00)00405-110.1016/S0142-9612(00)00405-1 ↗
2. 10.1016/S0043-1648(98)00356-110.1016/S0043-1648(98)00356-1 ↗
3. 10.1007/BF0267258110.1007/BF02672581 ↗
4. 10.1016/S0142-9612(99)00079-410.1016/S0142-9612(99)00079-4 ↗
5. 10.1016/S0257-8972(97)00113-810.1016/S0257-8972(97)00113-8 ↗
6. 10.1088/0022-3727/25/5/02310.1088/0022-3727/25/5/023 ↗
7. 10.1016/S0257-8972(01)01441-410.1016/S0257-8972(01)01441-4 ↗
8. 10.1016/S0043-1648(99)00062-910.1016/S0043-1648(99)00062-9 ↗
9. 10.1016/S0257-8972(99)00007-910.1016/S0257-8972(99)00007-9 ↗
10. 10.1016/S0043-1648(99)00131-310.1016/S0043-1648(99)00131-3 ↗
11. 10.1557/JMR.1994.099210.1557/JMR.1994.0992 ↗
12. 10.1016/S0257-8972(03)00137-310.1016/S0257-8972(03)00137-3 ↗
13. Ion implantation and thermal nitridation of biocompatible titanium
14. 10.1088/0022-3727/36/15/31710.1088/0022-3727/36/15/317 ↗
15. 10.1063/1.35285210.1063/1.352852 ↗
16. 10.1063/1.34043710.1063/1.340437 ↗
17. 10.1063/1.33450410.1063/1.334504 ↗
18. 10.1063/1.32997710.1063/1.329977 ↗
19. 10.1002/jbm.a.2004310.1002/jbm.a.20043 ↗
20. 10.1016/j.physb.2004.07.00110.1016/j.physb.2004.07.001 ↗
21. 10.1016/S0022-0248(01)01742-010.1016/S0022-0248(01)01742-0 ↗
22. 10.1016/0169-4332(94)00545-110.1016/0169-4332(94)00545-1 ↗
23. 10.1016/0368-2048(92)80016-210.1016/0368-2048(92)80016-2 ↗
24. 10.1089/ten.2005.11.110.1089/ten.2005.11.1 ↗
25. 10.1016/S0094-1298(20)31020-810.1016/S0094-1298(20)31020-8 ↗
26. 10.1002/mabi.20040002610.1002/mabi.200400026 ↗
27. 10.1016/j.apsusc.2004.05.13410.1016/j.apsusc.2004.05.134 ↗
28. 10.1016/0142-9612(94)90038-810.1016/0142-9612(94)90038-8 ↗
29. 10.1016/j.biomaterials.2004.02.02110.1016/j.biomaterials.2004.02.021 ↗
30. 10.1016/S0927-7765(03)00116-410.1016/S0927-7765(03)00116-4 ↗
31. 10.1016/S0927-7765(98)00030-710.1016/S0927-7765(98)00030-7 ↗
32. Fibronectin adsorption on hydrophilic and hydrophobic surfaces detected by antibody binding and analyzed during cell adhesion in serum‐containing medium10.1016/S0021-9258(18)34609-X ↗
33. 10.1002/jbm.82015030810.1002/jbm.820150308 ↗
34. 10.1016/0304-3991(92)90417-I10.1016/0304-3991(92)90417-I ↗
35. 10.1016/0142-9612(94)90070-110.1016/0142-9612(94)90070-1 ↗
36. 10.1016/S0142-9612(99)00160-X10.1016/S0142-9612(99)00160-X ↗
37. 10.1016/S0142-9612(99)00242-210.1016/S0142-9612(99)00242-2 ↗
38. 10.1006/excr.1994.125710.1006/excr.1994.1257 ↗
39. 10.1002/jor.110014060610.1002/jor.1100140606 ↗