Biochemical comparisons of osteoarthritic human synovial fluid with calf sera used in knee simulator wear testing

J.‐M. Brandt, L. K. Brière, J. Marr, S. J. MacDonald, R. B. Bourne, J. B. Medley

Publisher page

Abstract

Abstract Osteoarthritic human synovial fluid was obtained from the knees of 20 patients and was compared with four different calf sera solutions frequently used as lubricants in knee simulator wear testing. Assuming that the fluid after arthroplasty was the same as the fluid in patients with osteoarthritis, the total protein concentration, protein constituent fractions, osmolality, trace element concentrations, and the thermal stability obtained via differential scanning calorimetry were determined. Human synovial fluid, with an average total protein concentration of 34 g/L, was significantly different from all undiluted calf sera. However, alpha‐calf serum and iron‐supplemented alpha‐calf serum were closest in protein constituent fractions (albumin, α‐1‐globulin, α‐2‐globulin, ß‐globulin, and γ‐globulin) to human synovial fluid. Diluting calf sera with low‐ion distilled water to a total protein concentration of 17 g/L (as recommended by ISO 14243) produced non‐clinically relevant total protein concentration and osmolality levels. Performing the same dilution of iron‐supplemented alpha‐calf serum with phosphate‐buffered saline solution and 1.5 g/L hyaluronic acid produced an artificial lubricant with both a clinically relevant level of osmolality and clinically relevant thermal stability as seen in human synovial fluid from patients with osteoarthritis. The present study suggested that alpha‐calf serum, phosphate‐buffered saline solution and hyaluronic acid were essential constituents of an artificial lubricant to mimic the major biochemical properties of human synovial fluid for simulator wear testing of total knee replacements. © 2010 Wiley Periodicals, Inc. J Biomed Mater Res Part A, 2010
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Total Knee Arthroplasty Outcomes · Lubricants and Their Additives

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (46)

Show source-provided references
1. 10.1243/095441197153466510.1243/0954411971534665 ↗
2. 10.1016/S0021-9290(96)00118-210.1016/S0021-9290(96)00118-2 ↗
3. ISO‐14243–1.International Organization for Standardization London: Implants for surgery: Wear of total knee joint prostheses. Part 1: loading and displacement parameters for wear testing machines with load control and corresponding environmental conditions for test.2002.
4. ISO‐14243–3.International Organization for Standardization London: Implants for Surgery: Wear of total knee joint prostheses. Part 3: Loading and displacement parameters for wear testing machines with displacement control and corresponding environmental conditions for test.2004.
5. 10.1243/095441101153601910.1243/0954411011536019 ↗
6. 10.1002/(SICI)1097-4636(1999)48:4<465::AID-JBM10>3.0.CO;2-Y10.1002/(SICI)1097-4636(1999)48:4<465::AID-JBM10>3.0.CO;2-Y ↗
7. 10.1016/j.biomaterials.2003.11.02310.1016/j.biomaterials.2003.11.023 ↗
8. Atkinson K · 2003 · 203
9. 10.1172/JCI10508110.1172/JCI105081 ↗
10. 10.1016/S0043-1648(03)00180-710.1016/S0043-1648(03)00180-7 ↗
11. 10.1016/S0142-9612(03)00148-010.1016/S0142-9612(03)00148-0 ↗
12. 10.1016/S0043-1648(03)00183-210.1016/S0043-1648(03)00183-2 ↗
13. Influence of tray surface finish on modular tibial tray micromotion and wear
14. 10.1002/pro.556005031210.1002/pro.5560050312 ↗
15. 10.1016/0301-4622(94)00050-610.1016/0301-4622(94)00050-6 ↗
16. 10.1016/S0141-8130(96)01153-110.1016/S0141-8130(96)01153-1 ↗
17. 10.1016/0043-1648(85)90067-510.1016/0043-1648(85)90067-5 ↗
18. 10.1006/jcis.1995.103910.1006/jcis.1995.1039 ↗
19. 10.1038/icb.1996.3210.1038/icb.1996.32 ↗
20. MazzuccoD.Variation in joint fluid composition and its effect on the tribology of replacement joint articulation PhD Thesis. MIT 2003.
21. Hyaluronate in total hip replacement
22. 10.1098/rsif.2005.008610.1098/rsif.2005.0086 ↗
23. 10.1243/09544119JEIM3010.1243/09544119JEIM30 ↗
24. 10.1016/j.bpc.2006.05.00410.1016/j.bpc.2006.05.004 ↗
25. 10.1016/j.biomaterials.2004.05.02010.1016/j.biomaterials.2004.05.020 ↗
26. 10.1016/S0141-8130(97)01159-810.1016/S0141-8130(97)01159-8 ↗
27. Madigan MT · 2006 · 274
28. 10.1007/s10973-010-0794-910.1007/s10973-010-0794-9 ↗
29. BCA™ Protein Assay Kit: Instructions. Pierce Chemicals PO Box 117 Rockford IL 61105.
30. Streyer L · 1995
31. 10.2106/00004623-198567090-0000510.2106/00004623-198567090-00005 ↗
32. Influence of polyethylene processing. Tibial surface finish and modular locking mechanism design on in‐vitro wear for total knee arthroplasty
33. McNultyD SwopeSW.Wear of non‐modular and modular total knee tibial components. Proceedings of the 31th Annual Meeting of the Society for Biomaterials Memphis TN 2005.
34. 10.1243/095441105X3439210.1243/095441105X34392 ↗
35. 2005
36. 2005
37. 2005
38. 2005
39. 10.1016/j.apsusc.2007.02.01610.1016/j.apsusc.2007.02.016 ↗
40. 10.1161/01.CIR.96.3.103110.1161/01.CIR.96.3.1031 ↗
41. 10.1002/jbm.82012061110.1002/jbm.820120611 ↗
42. Calf serum type affects protein degradation, bacterial growth and polyethylene wear in knee simulator testing
43. 10.1007/BFb006770010.1007/BFb0067700 ↗
44. 10.1248/cpb.48.77910.1248/cpb.48.779 ↗
45. TsunenagaM TominagaN NishiyamaT YamashitaT FukuyamaM MiyataT FuruseM. Hyaluronic acid‐containing aqueous solution or aqueous dispersion of collagen. U.S. Patent 5 137 875.1992.
46. 10.1007/s10973-005-7170-110.1007/s10973-005-7170-1 ↗