journal article·2024-10-12

A High-Sensitivity D-Shaped Microgroove Photonic Crystal Fiber Gas Sensor Based on Surface Plasmon Resonance

Xiaoyong Gan, Hongzhi Xu, Shubo Jiang

Plasmonics· Volume 20· Issue 6
Publisher page

Abstract

Abstract A D-shaped open-ring microgroove photonic crystal fiber (PCF) sensor based on surface plasmon resonance (SPR) is proposed for the simultaneous measurement of methane gas concentration and temperature. The sensitive coatings are polysiloxane-doped cryptane E and polydimethylsiloxane (PDMS), and the designed microgroove structure with out-of-hole coating is expected to improve the sensitivity. The finite element method (FEM) is employed to analyze the data numerically, and the results demonstrated that the average sensitivities could reach − 96.57 nm/% for methane concentration in the range of 0.5 ~ 3.0% and − 6.86 nm/°C for methane temperature in the range of 0 ~ 50℃. Both measurement channels exhibited excellent linearity, making them highly valuable for environmental monitoring and other applications.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Advanced Fiber Optic Sensors · Photonic and Optical Devices · Plasmonic and Surface Plasmon Research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (31)

Show source-provided references
1. Yuxin L, Hailiang C, Qiang C et al (2023) Surface plasmon resonance induced methane gas sensor in hollow core anti-resonant fiber. Opt Fiber Technol 78:10329310.1016/j.yofte.2023.103293 ↗
2. Quansheng J, Rongjun S, Lei W et al (2023) Influence of initial gas concentration on methane–air mixtures explosion characteristics and implications for safety management. Sci Rep 13(1):13519–1351910.1038/s41598-023-40383-3 ↗
3. Markos C, Travers JC, Abdolvand A et al (2017) Hybrid photonic-crystal fiber. Rev Modern Phys 89(4):04500310.1103/RevModPhys.89.045003 ↗
4. Karol K, Piotr J, Lukas T et al (2024) Photothermal gas detection using a miniaturized fiber Fabry-Perot cavity. Sens Actuators: B Chem 401:13504010.1016/j.snb.2023.135040 ↗
5. Dong Z, Qingxiu W, Zeqing L et al (2023) Liquid-crystal-based fiber laser sensor for non-invasive gas detection. Opt Lett 48(17):4508–451110.1364/OL.489552 ↗
6. Singh DG, Ankit P, Kumar SM et al (2022) An interplay between lossy mode resonance and surface plasmon resonance and their sensing applications. Biosensors 12(9):721–72110.3390/bios12090721 ↗
7. Villar DI, Arregui JF, Zamarreño RC et al (2017) Optical sensors based on lossy-mode resonances. Sens Actuators: B Chem 240:174–18510.1016/j.snb.2016.08.126 ↗
8. Kumar S, Yadav CG, Sharma G et al (2018) Study of surface plasmon resonance sensors based on silver–gold nanostructure alloy film coated tapered optical fibers. Appl Phys A 124(10):1–710.1007/s00339-018-2120-5 ↗
9. Zhigang G, Hailiang C, Lida L et al (2023) Temperature compensation measurements in the detection of glucose and sodium chloride solution concentration based on SPR in the optical fiber. Infrared Phys Technol 135:10499810.1016/j.infrared.2023.104998 ↗
10. Haoran W, Weiyu D, Xun C et al (2021) Half-side PDMS-coated dual-parameter PCF sensor for simultaneous measurement of seawater salinity and temperature. Opt Fiber Technol 65:10260810.1016/j.yofte.2021.102608 ↗
11. Pradhan SH (2023) Characterization of a high-performance PCF-SPR sensor for biomedical applications. Curr Anal Chem 19(8):585–59410.2174/1573411019666230616101033 ↗
12. Qiang L, Jin Z, Yudan S et al (2021) High-sensitivity methane sensor composed of photonic quasi-crystal fiber based on surface plasmon resonance. J Opt Soc Am A 38(10):1438–1442. Optics, image science, and vision10.1364/JOSAA.432045 ↗
13. Liu H, Wang H, Chen C et al (2020) High sensitive methane sensor based on twin-core photonic crystal fiber with compound film-coated side-holes. Opt Quant Electron 52:8110.1007/s11082-020-2198-9 ↗
14. Zimu W, Peng G, Songwei L et al (2021) A reflective methane concentration sensor based on biconvex cone photonic crystal fiber. Optik 241:16698310.1016/j.ijleo.2021.166983 ↗
15. Abbaszadeh A, Makouei S, Meshgini S (2021) High sensitive triangular photonic crystal fiber sensor design applicable for gas detection. Adv Electromagn 9(1)10.7716/aem.v9i1.1539 ↗
16. Yuxin L, Hailiang C, Hongwei L et al (2023) Highly sensitive methane gas sensor based on Au/UVCFS films coated D-shaped photonic crystal fiber. Phys Scr 98(6):06553310.1088/1402-4896/acd7af ↗
17. Hai L, Bo W, Cong C et al (2022) D-shaped tellurite photonic crystal fiber hydrogen and methane sensor based on four-wave mixing with SPR effect. Photonic Sens 13(1):230121
18. Nan YZ, Min TZ, Bo H et al (2018) Simultaneous measurement of hydrogen concentration and temperature based on fiber loop mirror combined with PCF. IEEE Sens J 18(6):2369–237610.1109/JSEN.2018.2801831 ↗
19. Xiao Y, Jiang Z, Yin B et al (2024) Simultaneous measurement of hydrogen and methane concentrations with temperature self-calibration based on a SPR sensor with an anchor-shaped photonic crystal fiber. Opt Laser Technol 175:11088010.1016/j.optlastec.2024.110880 ↗
20. SharmaK A, GuptaD B (2007) On the performance of different bimetallic combinations in surface plasmon resonance based fiber optic sensors. J Appl Phys 101(9):09311110.1063/1.2721779 ↗
21. Ahmad AO, Alrashid TNS, Khalaf KM (2024) Study the optical properties of noble metal (Au, Ag, and Cu) thin film biosensors based on surface plasmon resonance performance by a simulation program. Int J Nanosci 23(03):2350079–14110.1142/S0219581X23500795 ↗
22. Islam MR, Iftekher ANM, Etu MF et al (2023) Dual peak double resonance sensing using a dual plasmonic material PCF-SPR sensor. Plasmonics 18:983–99310.1007/s11468-023-01829-6 ↗
23. Minz RA, Pal SS, Chopra A et al (2017) Magnetron sputtering coated optical fiber probe designs for surface plasmon resonance sensor. IEEE J Selected Topics Quantum Electron 23(2):119–12510.1109/JSTQE.2016.2613859 ↗
24. Wenjun L, Mengli L, Jinde Y et al (2018) Tungsten diselenide for all-fiber lasers with the chemical vapor deposition method. Nanoscale 10(17):7971–797710.1039/C8NR00471D ↗
25. Zhang G, Sun Y, Qian B et al (2020) Experimental study on mechanical performance of polydimethylsiloxane (PDMS) at various temperatures. Polym Test 90:10667010.1016/j.polymertesting.2020.106670 ↗
26. Liu Hai et al (2018) Simultaneous measurement of hydrogen and methane based on PCF-SPR structure with compound film-coated side-holes. Opt Fiber Technol 45:1–710.1016/j.yofte.2018.05.007 ↗
27. Zhiyong Y, Xili J, Ge B et al (2022) A broadband SPR dual-channel sensor based on a PCF coated with sodium-silver for refractive index and temperature measurement. Results Phys 41:10594310.1016/j.rinp.2022.105943 ↗
28. Tao L, Deng S, Gao H et al (2020) Experimental investigation of the dielectric constants of thin noble metallic films using a surface plasmon resonance sensor. Sensors 20(5):1505–150510.3390/s20051505 ↗
29. Li C, Yang W, Wang M et al (2020) A review of coating materials used to improve the performance of optical fiber sensors. Sensors 20(15):421510.3390/s20154215 ↗
30. Zhang Z, Shen T, Wu H et al (2021) A temperature sensor based on D-shape photonic crystal fiber coated with Au–TiO2 and Ag–TiO2. Opt Quant Electron 53:67810.1007/s11082-021-03336-6 ↗
31. Yuxin L, Hailiang C, Hongwei L et al (2023) Ultra-high sensitivity methane gas sensor based on vernier effect in double D-shaped and cryptophane-A film-coated photonic crystal fiber: design and FEM simulation. Results Phys 52:10684010.1016/j.rinp.2023.106840 ↗