journal article·2018-04

Improved Sensitivity of 2D Photonic Crystal Mach–Zehnder Interferometer-Based Pressure Sensor

Bendib Sarra, Zegadi Ameur

Plasmonics· Volume 13· Issue 2
Publisher page

Abstract

In this paper, we design and simulate a two-dimensional photonic crystal MZI for pressure sensing with a high sensitivity. The sensor is formed by silicon rods of a rectangular lattice distributed in air wafer; when the pressure is applied in an area of rods situated between the Y branch waveguides of MZI, the sensitivity achieved a very high value which is 22.3667 nm/GPa compared to that obtained when the pressure was applied over the entire surface of the sensor structure in which the sensitivity reached 6.36 nm/GPa.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Photonic Crystals and Applications · Photonic and Optical Devices · Advanced Fiber Optic Sensors

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (24)

Show source-provided references
1. Shanthi KV, Robinson S (2014) Two-dimensional photonic crystal based sensor for pressure sensing. Photonic Sensors 4(3):248–25310.1007/s13320-014-0198-8 ↗
2. Upadhyay S, Kalyani VL (2016) Designing of ring–resonator based photonic pressure sensor. IJIR 2(4):999–1003
3. Hai-wei FU, Hui Z, Xue-guang Q, Yan LI, Da-zhuang Z (2011) Study on a novel photonic crystal temperature sensor. Optoelectron Lett 7(6):2–5
4. Yu Y, Zhang Y, Ou Z, Chen X, Huang Q, Ruan S (2015) Simultaneous measurement of one dimensional bending and temperature based on Mach-Zehnder interferometer. Photonic Sensors 5(4):376–38410.1007/s13320-015-0264-x ↗
5. Wong WC, Chan CC, Gong H, Leong KC (2011) Mach–Zehnder photonic crystal interferometer in cavity ring-down loop for curvature measurement. IEEE Photon Technol Lett 23(12):795–79710.1109/LPT.2011.2132796 ↗
6. Suh W, Solgaard O, Fan S (2005) Displacement sensing using evanescent tunneling between guided resonances in photonic crystal slabs. J Appl Phys 98(3):03310210.1063/1.1999031 ↗
7. Shruthi SV, Bahaddur I (2016) Design and modeling of photonic crystal based pressure sensor. IJSEAS 2(6):349–355
8. Upadhyay S (2015) High sensitive refractive index sensor based on 2D-photonic crystal. IJERT 4(02)
9. Tsai T, Wang C, Wang H, Chang I, Chen L (2015) A high-resolution refractive index sensor based on a magnetic photonic crystal. World Academy of Science, Engineering and Technology, International Journal of Mathematical, Computational, Physical, Electrical and Computer Engineering 9(7):415–419
10. Benz A, Deutsch C, Brandstetter M, Andrews AM, Klang P, Detz H, Unterrainer K (2011) Terahertz active photonic crystals for condensed gas sensing. Sensors 11(6):6003–601410.3390/s110606003 ↗
11. Li Z, Liao C, Wang Y, Xu L, Wang D, Liu S, Wang Q, Yang K, Zhou J (2015) Highly-sensitive gas pressure sensor using twin- core fiber based in-line Mach-Zehnder interferometer. Opt Express 23(5):2827–2830
12. Massaro A (2008) Photonic crystal waveguides and bio-sensors
13. Silveira LCA, Hejase JA, Chahal P A terahertz photonic crystal structure for sensing applications. pp. 1–2
14. Pinet É (2011) Pressure measurement with fiber-optic sensors: commercial technologies and applications. 21st Int Conf Opt Fiber Sensors 7753(1–4):77530410.1117/12.895536 ↗
15. Tao S, Chen D, Wang J, Qiao J, Duan Y (2016) A high sensitivity pressure sensor based on two-dimensional photonic crystal. Photonic Sensors 6(2):137–14210.1007/s13320-016-0316-x ↗
16. Jin X, Yu XH, Zargar S, Patel RH, Wards S (2008) A pressure sensing system using fiber optic sensors and artificial neural networks. 2008 I.E. Avion Fiber-Optics Photonics Technol Conf 2:35–36
17. Poeggel S, Tosi D, Duraibabu D, Leen G, McGrath D, Lewis E (2015) Optical fibre pressure sensors in medical applications. Sensors 15(7):17115–1714810.3390/s150717115 ↗
18. Yang D, Tian H, Wu N, Yang Y, Ji Y (2013) Torsion-free photonic crystal pressure sensor array using novel piston-type resonator array. Lasers and Electro-Optics (CLEO), 2013 Conference on IEEE, 9-14 June 201310.1364/CLEO_SI.2013.CM4O.2 ↗
19. Olyaee S, Dehghani AA (2012) Photonic Sensors High resolution and wide dynamic range pressure sensor based on two-dimensional photonic crystal. 2(1):92–9610.1007/s13320-011-0044-1 ↗
20. Olyaee S, Dehghani AA (2012) Nano-pressure sensor using high quality photonic crystal cavity resonator., pp 3–6
21. Camargo EA, Chong HMH, La Rue RMD, Avenue O, Glasgow G, De Aeronáutica IT, Aeroespacial CT, Eduardo PM, José S, Paulo S (2004) Mach-Zehnder channel-guide device structure based on 2D photonic crystal. SPIE 5450:333–343
22. Li X, Xu Y (2013) Optical sensing by using photonic crystal based Mach–Zehnder interferometer. Opt Commun J 302:7–1110.1016/j.optcom.2013.03.038 ↗
23. Upadhyay S (2015) High sensitive refractive index sensor based on 2D-photonic crystal. Int J Math Comput Phys Electr Comput Engrg 9(7)