Modification of structural, mechanical, corrosion and biocompatibility properties of Ti40Zr10Cu36Pd14 metallic glass by minor Ga and Sn additions
Source abstract
Abstract
Ti 40Zr 10Cu 32Pd 14Ga 4 and Ti 40Zr 10Cu 32Pd 14Sn 4 (in at%) bulk metallic glasses (BMGs) with different geometries (wedges, rods, ribbons and discs) were prepared by suction casting, melt spinning and splat quenching, respectively. For comparison, the reference Ti 40Zr 10Cu 36Pd 14 BMG was cast as a rod with 2 mm diameter and in wedge-shaped form. High-energy X-ray diffraction measurements yielded a critical casting thickness of 2.4, 2.1 and at least 4 mm for the reference, Ga-containing, and Sn-containing BMGs, respectively. The extension of the supercooled liquid region of about 50 K, measured for the glassy rods and ribbons by differential scanning calorimetry, is larger than that of only 20 K found for the splat-quenched discs. As to the alloys’ mechanical properties, the Ti 40Zr 10Cu 36Pd 14 glassy rods deform plastically in compression up to a strain of 3.8% and possess a Young’s modulus of 78 GPa. The Sn- and Ga- containing BMG rods reach respectively a plastic strain of 6.1% and 4.7%, and a Young’s modulus of 72 and 63 GPa. Corrosion tests were performed by electrochemical experiments, and the highest pitting resistance was observed for Ti 40Zr 10Cu 32Pd 14Sn 4 (pitting overpotential η pit = 446 mV) compared to Ti 40Zr 10Cu 32Pd 14Ga 4 (379 mV) and Ti 40Zr 10Cu 36Pd 14 (183 mV). The results of live/dead assay and cell viability revealed excellent biocompatibility for the Ga-containing BMGs.
Source: expertdata · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Metallic Glasses and Amorphous Alloys · High Entropy Alloys Studies · Surface Treatment and Coatings
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (55)
Show source-provided references
1. Suryanarayana · 2017
2. Recent advancements in bulk metallic glasses and their applications: a review10.1080/10408436.2017.1358149 ↗
3. Production, mechanical properties and biomedical characterization of ZrTi-based bulk metallic glasses in comparison with 316L stainless steel and Ti6Al4V alloy10.3390/ma15010252 ↗
4. Formation and properties of biocompatible Ti-based bulk metallic glasses in the Ti–Cu–Zr–Fe–Sn–Si–Ag system10.1016/j.jnoncrysol.2021.121060 ↗
5. Bulk metallic glasses10.1016/j.mser.2004.03.001 ↗
6. Bulk metallic glasses10.1016/S0966-9795(03)00046-3 ↗
7. Tailoring biocompatible Ti-Zr-Nb-Hf-Si metallic glasses based on high-entropy alloys design approach10.1016/j.msec.2020.111733 ↗
8. Mechanical properties of metallic glasses10.3390/met3010077 ↗
9. The elastic properties, elastic models and elastic perspectives of metallic glasses10.1016/j.pmatsci.2011.07.001 ↗
10. Corrosion and related mechanical properties of bulk metallic glasses10.1557/jmr.2007.0051 ↗
11. MgZnCa glasses without clinically observable hydrogen evolution for biodegradable implants10.1038/nmat2542 ↗
12. Improved plasticity and corrosion behavior in Ti–Zr–Cu–Pd metallic glass with minor additions of Nb: an alloy composition intended for biomedical applications10.1016/j.msea.2012.08.058 ↗
13. Zr–Ti–Al–Fe–Cu bulk metallic glasses for biomedical device application10.1007/s12598-020-01644-6 ↗
14. Agrawal · 2013
15. Wong · 2012
16. Physical and mechanical properties of metallic biomaterials
17. Ti based biomaterials, the ultimate choice for orthopaedic implants – A review10.1016/j.pmatsci.2008.06.004 ↗
18. Young’s modulus, bending strength, and tissue physical properties of human compact bone10.1002/jor.1100080416 ↗
19. Park · 2002
20. S.L. Zhu, X.M. Wang, F.X. Qin, A. Inoue, A New Ti-based Bulk Glassy Alloy with Potential for Biomedical Application, 459, 2007, pp. 233–237. 〈https://doi.org/10.1016/j.msea.2007.01.044〉.10.1016/j.msea.2007.01.044 ↗
21. Metallic biomaterials
22. Nickel: human health and environmental toxicology10.3390/ijerph17030679 ↗
23. Young’s modulus and damping of Ti-6Al-4V alloy as a function of heat treatment and oxygen concentration10.1016/0921-5093(90)90097-M ↗
24. Characterization and mechanical proprieties of new TiMo alloys used for medical applications10.3390/ma12182973 ↗
25. In-depth assessment of new Ti-based biocompatible materials10.1016/j.matchemphys.2020.123959 ↗
26. Effect of surface modifications of Ti40Zr10Cu38Pd12 bulk metallic glass and Ti-6Al-4V alloy on human osteoblasts in vitro biocompatibility10.1371/journal.pone.0156644 ↗
27. Niinomi · 2015
28. Review on the research and development of Ti-based bulk metallic glasses10.3390/met6110264 ↗
29. S.L. Zhu, X.M. Wang, A. Inoue, Glass-Forming Ability and Mechanical Properties of Ti-based Bulk Glassy Alloys with Large Diameters of up to 1 cm, 16, 2008, pp. 1031–1035. 〈https://doi.org/10.1016/j.intermet.2008.05.006〉.10.1016/j.intermet.2008.05.006 ↗
30. S. Bera, P. Ramasamy, B. Sarac, C. Gammer, M. Stoica, M. Calin, Tuning the Glass Forming Ability and Mechanical Properties of Ti-based Bulk Metallic Glasses by Ga Additions, 793, 2019, pp. 552–563. 〈https://doi.org/10.1016/j.jallcom.2019.04.173〉.10.1016/j.jallcom.2019.04.173 ↗
31. Effect of alloying elements on the microstructure and corrosion behavior of TiZr-based bulk metallic glasses10.1016/j.corsci.2020.108854 ↗
32. Investigation of glass-forming ability, deformation and corrosion behavior of Ni-free Ti-based BMG alloys designed for application as dental implants10.1016/j.msec.2008.07.009 ↗
33. I12: the joint engineering, environment and processing (JEEP) beamline at diamond light source10.1107/S1600577515003513 ↗
34. Complete elliptical ring geometry provides energy and instrument calibration for synchrotron-based two-dimensional X-ray diffraction10.1107/S0021889813022437 ↗
35. Processing two-dimensional X-ray diffraction and small-angle scattering data in DAWN 210.1107/S1600576717004708 ↗
36. A theory of the electrical properties of liquid metals10.1080/14786436508211931 ↗
37. PDFgetX2: a GUI-driven program to obtain the pair distribution function from X-ray powder diffraction data10.1107/S0021889804011744 ↗
38. R.E. Smallman, A.H.W. Ngan, Modern Physical Metallurgy, Eighth, Butterworth-Heinemann is an imprint of Elsevier, Oxford, 2014. 〈https://doi.org/10.1016/C2011-0-05565-5〉.10.1016/C2011-0-05565-5 ↗
39. Influence of casting parameters on the critical casting size of bulk metallic glass10.1007/s11661-009-9929-7 ↗
40. Cooling rates in splat cooling10.1016/0025-5416(67)90013-4 ↗
41. Under what conditions can a glass be formed?10.1080/00107516908204405 ↗
42. Stick-slip dynamics and recent insights into shear banding in metallic glasses10.1557/jmr.2011.178 ↗
43. Shear-band dynamics in metallic glasses10.1002/adfm.201404223 ↗
44. FeCoSiBNbCu bulk metallic glass with large compressive deformability studied by time-resolved synchrotron X-ray diffraction10.1063/1.4864671 ↗
45. Intrinsic plasticity or brittleness of metallic glasses10.1080/09500830500080474 ↗
46. Corrosion behavior of a Ti-based bulk metallic glass and its crystalline alloys10.2320/matertrans.MJ200713 ↗
47. Q. Wei, No Title, University of Birmingham, 2020. 〈https://etheses.bham.ac.uk//id/eprint/10046/〉.
48. The influence of partial replacement of Cu with Ga on the corrosion behavior of Ti40Zr10Cu36Pd14 metallic glasses10.1149/2.0461914jes ↗
49. Pitting corrosion of metals: a review of the critical factors10.1149/1.1838615 ↗
50. Osteoblast adhesion on biomaterials10.1016/S0142-9612(99)00242-2 ↗
51. Comparison of osteoblast spreading on microstructured dental implant surfaces and cell behaviour in an explant model of osseointegration10.1111/j.1600-0501.2005.01168.x ↗
52. Gallium ions promote osteoinduction of human and mouse osteoblasts via the TRPM7/Akt signaling pathway10.3892/mmr.2020.11346 ↗
53. A novel Ti-based nanoglass composite with submicron–nanometer-sized hierarchical structures to modulate osteoblast behaviors10.1039/c3tb20153h ↗
54. Wettability of substrata controls cell–substrate and cell–cell adhesions10.1016/j.bbagen.2007.07.008 ↗
55. Modulation of cell adhesion, proliferation and differentiation on materials designed for body implants10.1016/j.biotechadv.2011.06.004 ↗