Microstructure, mechanical behaviour and antibacterial activity of biomedical Ti-xMn-yCu alloys
Source abstract
Abstract
Abstract New ternary Ti-xMn-yCu alloys were designed aiming to develop Ti-based materials with antibacterial capability as pathogenic bacterial infection is a rising issue of metallic biomedical implants during surgery. The ternary Ti-xMn-yCu alloys are designed to be manufactured via powder metallurgy, which permits to successfully produce chemically homogeneous materials (key for a uniform antibacterial response) at lower cost. The methodical characterisation of Mn-dominant (Mn to Cu ratio of 3:1) and Cu-dominant (ratio of 1:3) ternary Ti-xMn-yCu alloys shows that the mechanical behaviour (tensile properties and hardness) and the in vitro antibacterial efficiency increase with the amount of alloying elements. Generally, Mn-dominant have better properties than Cu-dominant alloys but the latter are recommended for biomedical applications where high ductility is a critical requirement.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Titanium Alloys Microstructure and Properties · Orthopaedic implants and arthroplasty · Intermetallics and Advanced Alloy Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (50)
Show source-provided references
1. Recent metallic materials for biomedical applications10.1007/s11661-002-0109-2 ↗
2. Bioactive coating as a surface modification technique for biocompatible metallic implants: a review10.1080/21870764.2019.1669861 ↗
3. Ti based biomaterials, the ultimate choice for orthopaedic implants - a review10.1016/j.pmatsci.2008.06.004 ↗
4. Microstructures, mechanical properties and cytotoxicity of low cost beta ti-mn alloys for biomedical applications10.1016/j.actbio.2015.08.015 ↗
5. Vanadium and tungsten derivatives as antidiabetic agents: a review of their toxic effects10.1385/BTER:88:2:097 ↗
6. Relationship of aluminum to Alzheimer’s disease10.1289/ehp.8563149 ↗
7. The health effects of aluminum exposure
8. Toxicity, mechanism and health effects of some heavy metals10.2478/intox-2014-0009 ↗
9. The antibacterial properties and biocompatibility of a Ti-Cu Sintered alloy for biomedical application10.1088/1748-6041/9/2/025013 ↗
10. Modification of medical metals by ion implantation of copper10.1016/j.apsusc.2007.06.031 ↗
11. Functionally graded hydroxyapatite coatings doped with antibacterial components10.1016/j.actbio.2009.12.002 ↗
12. Plasma surface modification of titanium for hard tissue replacements10.1016/j.surfcoat.2004.02.045 ↗
13. Bacterial adhesion studies on titanium, titanium nitride and modified hydroxyapatite thin films10.1016/j.msec.2006.01.004 ↗
14. Mechanical properties of cast Ti-6Al-4V-xCu alloys10.1111/j.1365-2842.2004.01347.x ↗
15. Antibacterial properties of Ti-6Al-4V-xCu alloys10.1016/j.jmst.2013.12.014 ↗
16. Production and mechanical properties of Ti-5Al-2.5Fe-xCu alloys for biomedical applications10.1088/1748-605X/aa957d ↗
17. Fabrication of high strength, antibacterial and biocompatible Ti-5Mo-5Ag alloy for medical and surgical implant applications10.1016/j.msec.2019.110165 ↗
18. Effect of Cu content on the antibacterial activity of titanium-copper sintered alloys10.1016/j.msec.2013.11.028 ↗
19. Development of Cu-bearing powder metallurgy Ti alloys for biomedical applications10.1016/j.jmbbm.2019.05.014 ↗
20. Endangered elements, critical raw materials and conflict minerals10.1177/0036850419884873 ↗
21. The effect of deficiencies of manganese and copper on osteoinduction and on resorption of bone particles in rats10.1007/BF02563794 ↗
22. Role of Cu element in biomedical metal alloy design10.1007/s12598-019-01245-y ↗
23. Regulation of superoxide dismutase genes: implications in disease10.1016/j.freeradbiomed.2009.05.018 ↗
24. Novel titanium manganese alloys and their macroporous foams for biomedical applications prepared by field assisted sintering, biomedical engineering
25. Influence of vacuum hot-pressing temperature on the microstructure and mechanical properties of Ti-3Al-2.5V alloy obtained by blended elemental and master alloy addition powders10.1016/j.matchemphys.2012.10.010 ↗
26. Hybrid microwave sintering of blended elemental Ti alloys10.1016/j.jmapro.2019.02.002 ↗
27. Murray · 1987
28. Design of β-eutectoid bearing Ti alloys with antibacterial functionality10.1016/j.matlet.2020.128445 ↗
29. Japanese Standards Asociation, 2801: 2010 Antibacterial Products - Test for Antibacterial Activity and Efficacy.
30. The most suitable number of colonies on plates for counting10.4315/0362-028X-43.4.282 ↗
31. Investigation of the factors influencing the tensile behaviour of PM Ti-3Al-2.5V Alloy10.1016/j.msea.2014.05.017 ↗
32. Mechanical behaviour of pressed and sintered CP Ti and Ti-6Al-7Nb alloy obtained from master alloy addition powder10.1016/j.jmbbm.2012.08.022 ↗
33. National Food Safety Standard GB4789.2-2010, National Food Safety Standard Food Microbiological Examination: Aerobic Plate Count Ministry of Health of the People's Republic of China.
34. Theoretical design of titanium alloys
35. Chronic implant-related bone infections - can immune modulation be a therapeutic strategy?10.3389/fimmu.2019.01724 ↗
36. Materials Properties Handbook: Titanium Alloys
37. The optimum pore size for the fixation of porous surfaced metal implants by the ingrowth of bone10.1097/00003086-198007000-00045 ↗
38. Mechanical properties and microstructures of cast Ti-Cu alloys10.1016/S0109-5641(02)00027-1 ↗
39. Effects of composition and heat treatment on the mechanical behavior of Ti-Cu alloys10.1016/j.matdes.2013.10.050 ↗
40. Low-cost powder metallurgy Ti-Cu alloys as a potential antibacterial material10.1016/j.jmbbm.2019.04.004 ↗
41. Mechanical properties and microstructure of Ti-Mn alloys produced via powder metallurgy for biomedical applications10.1016/j.jmbbm.2018.12.005 ↗
42. Fabrication of low-cost beta-type ti-mn alloys for biomedical applications by metal injection molding process and their mechanical properties10.1016/j.jmbbm.2016.02.035 ↗
43. Mechanical behaviour of pressed and sintered titanium alloys obtained from prealloyed and blended elemental powders10.1016/j.jmbbm.2012.05.013 ↗
44. Comparison of metal concentrations in rat tibia tissues with various metallic implants10.1016/j.biomaterials.2004.01.064 ↗
45. Prevention of pin tract infection with titanium-copper alloys10.1002/jbm.b.31412 ↗
46. In vitro and In vivo studies of anti-bacterial copper-bearing titanium alloy for dental application10.1016/j.dental.2018.04.007 ↗
47. Effect of the existing form of cu element on the mechanical properties, bio-corrosion and antibacterial properties of Ti-Cu alloys for biomedical application10.1016/j.msec.2016.08.033 ↗
48. Influence of Cu content on the cell biocompatibility of Ti-Cu sintered alloys10.1016/j.msec.2014.10.021 ↗
49. Biocompatibility of antibacterial Ti-Cu sintered alloy: in vivo bone response10.1007/s10856-015-5600-6 ↗
50. Optimization of mechanical properties, biocorrosion properties and antibacterial properties of As-cast Ti-Cu alloys10.1088/1748-6041/11/6/065001 ↗