journal article·2021-02Open access

Extending a birdcage coil for magnetic resonance imaging of a human head with an artificial magnetic shield

K. Lezhennikova, C. Simovski, R. Abdeddaim, R. Balafendiev, S. Glybovski

Abstract

Abstract In magnetic resonance imaging, a birdcage coil is the most commonly used volumetric resonator creating a highly homogeneous radiofrequency magnetic field in a conductive sample. An artificial magnetic radiofrequency shield was recently shown to improve the magnetic field amplitude per unit power (transmit efficiency) of a preclinical birdcage coil by reducing the intrinsic losses in the coil and increasing power absorbed by the sample. In this paper, we propose a new application of an artificial shield in clinical MRI. Thanks to the proposed artificial shield a birdcage coil for human brain imaging operating at 300 MHz (Larmor frequency of protons at static fields of 7 T) can be expanded to increase free space. As a result, the coil becomes more comfortable for the patient and keeping comparable transmit efficiency. The same extended coil with a conventional copper shield would have at least 10% lower efficiency. The proposed artificial shield is implemented as an annular-ring cavity-backed slot in a copper cylinder that tightly surrounds the birdcage. To demonstrate the effect, radiofrequency magnetic field and specific absorption rate distributions were compared numerically and experimentally for the initial and extended coils with different shields.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Advanced MRI Techniques and Applications · Advanced NMR Techniques and Applications · Atomic and Subatomic Physics Research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (25)

Show source-provided references
1. 2016
2. Vaughan · 2012
3. The development of the birdcage resonator: a historical perspective10.1002/nbm.1431 ↗
4. Pros and cons of ultra-high-field MRI/MRS for human application10.1016/j.pnmrs.2018.06.001 ↗
5. R. Pohmann, O. Speck, K. Scheffler, Signal-to-noise ratio and MR tissue parameters in human brain imaging at 3,4, and 9.4 Tesla using current receive coil arrays, Magnetic Resonance in Medicine 75.10.1002/mrm.25677 ↗
6. B. Guerin, J. Villena, A. Polimeridis, E. Adalsteinsson, L. Daniel, J. White, L. Wald, The ultimate signal-to-noise ratio in realistic body models, Magnetic Resonance in Medicine 78.10.1002/mrm.26564 ↗
7. Ultra-high field NMR and MRI-the role of magnet technology to increase sensitivity and specificity10.3389/fphy.2017.00033 ↗
8. 7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images10.1002/mrm.1156 ↗
9. Transceiver-phased arrays for human brain studies at 7 T10.1007/s00723-011-0280-y ↗
10. N. Avdievich, G. Solomakha, L. Ruhm, J. Bause, K. Scheffler, A. Henning, Bent folded-end dipole head array for ultrahigh-field MRI turns “dielectric resonance” from an enemy to a friend, Magnetic resonance in medicine.
11. Parallel transmission for ultrahigh-field imaging10.1002/nbm.3313 ↗
12. J. Hoffmann, S. Gunamony, K. Scheffler, R. Pohmann, Numerical and experimental evaluation of RF shimming in the human brain at 9.4 T using a dual-row transmit array, Magma (New York, N.Y.) 27.10.1007/s10334-013-0419-y ↗
13. Radio frequency coil technology for small-animal MRI10.1002/nbm.1149 ↗
14. Radiative losses of a birdcage resonator10.1002/mrm.1910290522 ↗
15. A method for accurate calculation of B1 fields in three dimensions. Effects of shield geometry on field strength and homogeneity in the birdcage coil10.1006/jmre.1997.1136 ↗
16. Capolino · 2009
17. High-impedance electromagnetic surfaces with a forbidden frequency band10.1109/22.798001 ↗
18. Artificial magnetic conductor surfaces and their application to low-profile high-gain planar antennas10.1109/TAP.2004.840528 ↗
19. Artificially soft and hard surfaces in electromagnetics10.1109/8.59765 ↗
20. Electromagnetic field analysis of a dipole coil element with surface impedance characterized shielding plate for 7-T MRI10.1109/TMTT.2016.2518168 ↗
21. Improving B1 efficiency and signal-to-noise-ratio of a surface coil by a high-impedance-surface RF shield for 7-T magnetic resonance imaging10.1109/TMTT.2016.2631169 ↗
22. C. van Leeuwen, M. Lunenburg, S. Glybovski, P. Luijten, D. Klomp, C. van den Berg, A. Raaijmakers, Improved performance of birdcage coils using a split-ring resonator magnetic shield, In Proceedings of Joint Annual Meeting ISMRM - ESMRMB.
23. Constructive near-field interference effect in a birdcage MRI coil with an artificial magnetic shield10.1103/PhysRevApplied.13.064004 ↗
24. Phantom design method for high-field MRI human systems10.1002/mrm.20245 ↗
25. The virtual family-development of surface-based anatomical models of two adults and two children for dosimetric simulations10.1088/0031-9155/55/2/N01 ↗