journal article·2009-06-30Open access

Concrete Subjected to Varying Confinement, II: Modeling

Fatih Cetisli, Clay J. Naito

Abstract

A unique model for estimating the axial response of concrete under varying or constant levels of confinement is developed. The proposed model is empirically developed from a companion experimental study of concrete tested under linear, elastic perfectly plastic (EPP), elasto-plastic with strain hardening, and constant triaxial confinement. The axial stress-strain response is divided into three regions separated by two characteristic response levels. The model is based on the variation of the confining pressure due to the lateral dilation of the concrete. An estimate of dilation with respect to axial strain is also developed. The model is shown to provide an accurate prediction of historical experimental studies of constant confinement tests on cylinders, fiber reinforced polymer (FRP) jacketed specimens, and columns confined with conventional lateral reinforcement or FRP jacket.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Load-Bearing Analysis · Structural Response to Dynamic Loads

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Dept. of Civil Eng., Firat University, Elazig, Turkey.

Department of Civil and Env. Eng., Lehigh University, Bethlehem, PA, USA.

References (13)

Show source-provided references
1. Candappa, D. C., Sanjayan, J. G. and Setunge, S. (2001). “Complete triaxial stress-strain curves of high-strength concrete.” The Journal of Materials in Civil Engineering-ASCE, 13(3), 209-215.10.1061/(ASCE)0899-1561(2001)13:3(209) ↗
2. Cetisli, F. and Naito, C. J. (2009). “Concrete subjected to varying confinement, I: Experimental evaluation.” Journal of Advanced Concrete Technology, 7(2), 239-249.10.3151/jact.7.239 ↗
3. Kestner, J. T., Harries, K. A., Pessiki, S. P., Sause R. and Ricles, J. M. (1997). “Rehabilitation of reinforced concrete columns using fiber reinforced polymer composite jackets.” Bethlehem, PA, USA: Lehigh University ATLSS Engineering Research Center, Report No.97-07.
4. Lam, L. and Teng, J. G. (2002). “Strength models for fiber-reinforced plastic-confined concrete.” The Journal of Structural Engineering-ASCE, 128(5), 612-623.10.1061/(ASCE)0733-9445(2002)128:5(612) ↗
5. Madas, P. and Elnashai, A. S. (1992). “A new passive confinement model for the analysis of concrete structures subjected to cyclic and transient dynamic loading.” Earthquake Engineering and Structural Dynamics, 21, 409-431.10.1002/eqe.4290210503 ↗
6. Mander, J. B., Priestly, M. J. N. and Park, R. (1988a). “Theoretical stress-strain model for confined concrete.” The Journal of Structural Engineering-ASCE, 114(8), 1804-1826.10.1061/(ASCE)0733-9445(1988)114:8(1804) ↗
7. Mander, J. B., Priestly, M. J. N. and Park, R. (1988b). “Observed stress-strain behavior of confined concrete.” The Journal of Structural Engineering-ASCE, 114(8), 1827-1849.10.1061/(ASCE)0733-9445(1988)114:8(1827) ↗
8. Naito, C. J. and Cetisli, F. (2006). “Accuracy and improvements for variable and constant confinement concrete models.” In: SP-238: International Symposium on Confined Concrete. MI, USA: ACI, 238, 157-176.
9. Popovics, S. (1973). “A numerical approach to the complete stress-strain curve of the concrete.” Cement and Concrete Research, 3(4), 583-589.10.1016/0008-8846(73)90096-3 ↗
10. Razvi, S. and Saatcioglu, M. (1999). “Confinement model for high-strength concrete.” The Journal of Structural Engineering-ASCE, 125(3), 281-289.10.1061/(ASCE)0733-9445(1999)125:3(281) ↗
11. Richart, F. E., Brandtzaeg, A. and Brown, R. L. (1928). “A study of the failure of concrete under combined compressive stresses.” Illinois, USA: Engineering Experiment Station at University of Illinois, Bulletin No.:185.
12. Tan, T.-H. and Sun, X. (2006). “Failure criteria of concrete under triaxial compression.” In: SP-238: International Symposium on Confined Concrete. MI, USA: ACI, 235-248.
13. Xiao, Y. and Wu, H. (2000). “Compressive behavior of concrete confined by carbon fiber composite jackets.” The Journal of Materials in Civil Engineering-ASCE, 12(2), 139-146.10.1061/(ASCE)0899-1561(2000)12:2(139) ↗