journal article·2014-12-12Open access

Pore Structure and Permeation Characteristics of Foamed Concrete

Ameer A. Hilal, Nicholas H. Thom, Andrew R. Dawson

Abstract

A study has been undertaken to investigate the pore structure characteristics, porosity and critical pore diameter of preformed foamed concrete with a density between 1300 and 1900 kg/m3, and its effect on the permeation characteristics, water absorption and permeability. Different measured and calculated methods were adopted to determine the above properties and a comparison between them was done. Porosity was measured by apparent, total vacuum saturation and mercury intrusion porosimetry (MIP) methods, while permeability was measured (by constant and falling head methods) and calculated (by the Katz and Thompson model). Total porosity and dry density are found to be clearly related. The critical pore diameter (from the MIP test) and the pore diameter size (>200nm) are found to be closely related to the permeability of foamed concrete.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Concrete and Cement Materials Research · Grouting, Rheology, and Soil Mechanics · Concrete Properties and Behavior

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Civil Engineering Department, Faculty of Engineering, Univsersity of Anbar, Iraq, and PhD student, Department of Civil Engineering, Faculty of Engineering, University of Nottingham, Nottingham NG7 2RD, UK.

Department of Civil Engineering, Faculty of Engineering, University of Nottingham, Nottingham NG7 2RD, UK.

References (32)

Show source-provided references
1. 1) Akçay, B., (2007). “Effects of lightweight aggregates on autogenous deformation and fracture of high performance concrete.” Civil Engineering, Istanbul Technical University.
2. 2) Alshamsi, A. M. and Imran, H. D., (2002). “Development of a permeability apparatus for concrete and mortar.” Cement and Concrete Research, 32(6), 923-929.10.1016/S0008-8846(02)00727-5 ↗
3. 3) ASTM C144, (1987). “Standard Specification for Aggregate for Masonry Mortar.” American Society for Testing and Materials.
4. 4) ASTM C796, (1997). “Standard test method for foaming agent for use in producing cellular concrete using preformed foam.” American Society for Testing and Materials.
5. 5) BS 882, (1992). “Specification for aggregates from natural sources for concrete.” British Standards Institution, London.
6. 6) BS EN 197-1, (2011). “Cement-Part 1: Composition, Specifications and Conformity Criteria for Common Cements.”
7. 7) Christensen, B. J., Mason, T. O. and Jennings, H. M., (1996). “Comparison of measured and calculated permeabilities for hardened cement pastes.” Cement and Concrete Research, 26(9), 1325-1334.10.1016/0008-8846(96)00130-5 ↗
8. 8) Cui, L. and Cahyadi, J. H., (2001). “Permeability and pore structure of OPC paste.” Cement and Concrete Research, 31(2), 277-282.10.1016/S0008-8846(00)00474-9 ↗
9. 9) Diamond, S., (2000). “Mercury porosimetry: An inappropriate method for the measurement of pore size distributions in cement-based materials.” Cement and Concrete Research, 30(10), 1517-1525.10.1016/S0008-8846(00)00370-7 ↗
10. 10) El-Dieb, A. S. and Hooton, R. D., (1994). “Evaluation of the Katz-Thompson model for estimating the water permeability of cement-based materials from mercury intrusion porosimetry data.” Cement and Concrete Research, 24(3), 443-455.10.1016/0008-8846(94)90131-7 ↗
11. 11) Friedman, S. P. and Seaton, N. A., (1998). “Critical path analysis of the relationship between permeability and electrical conductivity of three-dimensional pore networks.” Water Resources Research, 34(7), 1703-1710.10.1029/98WR00939 ↗
12. 12) Goual, M., Bali, A., de Barquin, F., Dheilly, R. and Queneudec, M., (2006). “Isothermal moisture properties of clayey cellular concretes elaborated from clayey waste, cement and aluminium powder.” Cement and Concrete Research, 36(9), 1768-1776.10.1016/j.cemconres.2005.12.017 ↗
13. 13) Halamickova, P., Detwiler, R. J., Bentz, D. P. and Garboczi, E. J., (1995). “Water permeability and chloride ion diffusion in portland cement mortars: Relationship to sand content and critical pore diameter.” Cement and Concrete Research, 25(4), 790-802.10.1016/0008-8846(95)00069-O ↗
14. 14) Jitchaiyaphum, K., Sinsiri, T. and Chindaprasirt, P., (2011). “Cellular lightweight concrete containing pozzolan materials.” Procedia Engineering, 14, 1157-1164.10.1016/j.proeng.2011.07.145 ↗
15. 15) Jones, M. and McCarthy, A., (2005). “Preliminary views on the potential of foamed concrete as a structural material.” Magazine of Concrete Research, 57(1), 21-31.10.1680/macr.2005.57.1.21 ↗
16. 16) Katz, A. and Thompson, A., (1986). “Quantitative prediction of permeability in porous rock.” Physical review. B, Condensed Matter, 34(11), 8179-8181.10.1103/PhysRevB.34.8179 ↗
17. 17) Kearsley, E. and Wainwright, P., (2001a). “Porosity and permeability of foamed concrete.” Cement and Concrete Research, 31(5), 805-812.10.1016/S0008-8846(01)00490-2 ↗
18. 18) Kearsley, E. and Wainwright, P., (2002). “The effect of porosity on the strength of foamed concrete.” Cement and Concrete Research, 32(2), 233-239.10.1016/S0008-8846(01)00665-2 ↗
19. 19) Kearsley, E. P. and Wainwright, P. J., (2001b). “Porosity and permeability of foamed concrete.” Cement and Concrete Research, 31(5), 805-812.10.1016/S0008-8846(01)00490-2 ↗
20. 20) Li, H., Jiao, J. J. and Luk, M., (2004). “A falling-pressure method for measuring air permeability of asphalt in laboratory.” Journal of Hydrology, 286(1), 69-77.10.1016/j.jhydrol.2003.09.013 ↗
21. 21) Nambiar, E. and Ramamurthy, K., (2006). “Influence of filler type on the properties of foam concrete.” Cement and Concrete Composites, 28(5), 475-480.10.1016/j.cemconcomp.2005.12.001 ↗
22. 22) Nambiar, E. and Ramamurthy, K., (2007a). “Air‐void characterisation of foam concrete.” Cement and Concrete Research, 37(2), 221-230.10.1016/j.cemconres.2006.10.009 ↗
23. 23) Nambiar, E. K. K. and Ramamurthy, K., (2007b). “Sorption characteristics of foam concrete.” Cement and Concrete Research, 37(9), 1341-1347.10.1016/j.cemconres.2007.05.010 ↗
24. 24) Nambiar, E. K. K. and Ramamurthy, K., (2008). “Fresh state characteristics of foam concrete.” Journal of Materials in Civil Engineering, 20(2), 111-114.10.1061/(ASCE)0899-1561(2008)20:2(111) ↗
25. 25) Neville, A. M., (2011). “Properties of concrete.” 5th ed. Pearson Education Limited, London
26. 26) Othuman, M. A. and Wang, Y. C., (2011). “Elevated-temperature thermal properties of lightweight foamed concrete.” Construction and Building Materials, 25(2), 705-716.10.1016/j.conbuildmat.2010.07.016 ↗
27. 27) Ramamurthy, K., Nambiar, E. K. K. and Indu Siva Ranjani, G., (2009). “A classification of studies on properties of foam concrete.” Cement and Concrete Composites, 31(6), 388-396.10.1016/j.cemconcomp.2009.04.006 ↗
28. 28) Sanjuan, M. and Munoz-Martialay, R., (1996a). “Modelling of the concrete air permeability evolution over time.” Materials Letters, 27(4), 269-272.10.1016/0167-577X(95)00284-7 ↗
29. 29) Sanjuan, M. A. and Munoz-Martialay, R., (1996b). “Influence of the water/cement ratio on the air permeability of concrete.” Journal of Materials Science, 31(11), 2829-2832.10.1007/BF00355989 ↗
30. 30) Yang, C., Cho, S. and Wang, L., (2006). “The relationship between pore structure and chloride diffusivity from ponding test in cement-based materials.” Materials Chemistry and Physics, 100(2), 203-210.10.1016/j.matchemphys.2005.12.032 ↗
31. 31) Yen, L. B., (2007). “Study of water ingress into foamed concrete.” Department of Civil Engineernig, National University of Singapore.
32. 32) Yu, X. G., Luo, S. S., Gao, Y. N., Wang, H. F., Li, Y. X., Wei, Y. R. and Wang, X. J., (2011). “Pore structure and microstructure of foam concrete.” Advanced Materials Research, 177, 530-532.