Dual‐Mode Phase‐Doppler Anemometer
Source abstract
Abstract
Abstract The accurate measurement of mass flux is identified as being essential for the successful use of phase‐Doppler anemometry (PDA) in many applications, in particular with sprays. Thus measured sizes of individual droplets and the cross‐sectional area to which the flux measurement is referenced must be reliable. This paper investigates sources of measurement error in each of these quantities and provides means to eliminates or minimize these errors. A new PDA configuration, termed dual–mode PDA, is introduced as an implementation of these suggestions. Example measurements illustrate the advantages of the system over conventional arrangements.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Particle Dynamics in Fluid Flows · Atmospheric aerosols and clouds · Laser-induced spectroscopy and plasma
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (11)
Show source-provided references
1. M.Saffman:The Use of Polarized Light for Optical Particle Sizing. Proc. Anemometry in Fluid Mechanics‐III LADOAN—Instituto Superior Técnico Lisbon 1986 pp.387–398.
2. G.Gréhan G.Gouesbet A.Naqwi F.Durst:Evaluation of a Phase Doppler System using Generalized Lorenz‐Mie Theory. Proc. Int. Conf. on Multiphase Flows '91 Tsukuba Japan 1991 pp.291–296.
3. S. V.Sankar A.Inenaga W. D.Bachalo: Trajectory Dependent Scattering in Phase Doppler Interferometry: Minimizingand Eliminating Sizing Error. Proc. 6th Int. Symp. of Appl. of Laser Techn. to Fluid Mechanics LADOAN Lisbon 1992.10.1007/978-3-662-02885-8_6 ↗
4. F.Durst C.Tropea T.‐H.Xu:The Slit Effect in Phase Doppler Anemometry. Proc. 2nd Int. Conf. on Fluid Dyn. Meas. and its Appl. Beijing 1994.
5. 10.1088/0957-0233/5/8/01710.1088/0957-0233/5/8/017 ↗
6. C.Tropea T.‐H.Xu F.Onofri G.Gréhan P.Haugen:Dual Mode Phase Doppler Anemometry. Proc. 7th Int. Symp. on Appl. of Laser Anemom. to Fluid Mech. Lisbon 1994.
7. Y.Aizu F.Durst G.Gréhan F.Onofri T.‐H.Xu:PDA‐System Without Gaussian Beam Defects. Proc. 3rd Int. Conf. Optical Part. Sizing '93 Yokohama Japan 1993 pp.461–470.
8. 10.1364/AO.26.00259210.1364/AO.26.002592 ↗
9. 10.1364/AO.30.00494910.1364/AO.30.004949 ↗
10. H.Mignon G.Gréhan G.Gouesbet T.‐H.Xu C.Tropea:Measurement of Cylindrical Particles Using Phase‐Doppler Anemometry. Submitted to Appl. Opt.1995.10.1364/AO.35.005180 ↗
11. F.Schöne M.Stieglmeier C.Tropea T.‐H.Xu F.Onofri G.Gréhan:Measurement of Diameter and Velocity of Fibers Using Dual PDA.Proc. Laser 95 Congress Munich 1995.