Mohamed A. Koronfel, Angela E. Goode, Johanna Nelson Weker, Stephen E. R. Tay, Camilla A. Stitt, Thiago A. Simoes, J. Frederick. W. Mosselmans, Paul Quinn, Rik Brydson, Alister Hart, Michael F. Toney, Alexandra E. Porter, Mary P. Ryan

npj Materials Degradation· Volume 2· Issue 1

Abstract

Abstract CoCrMo-based metal-on-metal hip implants experienced unexpectedly high failure rates despite the high wear and corrosion resistance of the bulk material. Although they exhibit a lower volumetric wear compared to other implant materials, CoCrMo-based implants produced a significantly larger 'number' of smaller wear particles. CoCrMo is nominally an extremely stable material with high Cr content providing passivity. However, despite the Co:Cr ratio in the original alloy being 2:1; chemical analyses of wear particles from periprosthetic tissue have found the particles to be composed predominately of Cr species, with only trace amounts of Co remaining. Here a correlative spectroscopy and microscopy approach has shown that these particles dissolve via a non-stoichiometric, and geometrically inhomogeneous, mechanism similar to de-alloying. This mechanism is previously unreported for this material and was not apparent in any of the regulatory required tests, suggesting that such tests are insufficiently discriminating.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Advanced materials and composites · Orthopedic Infections and Treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (27)

Show source-provided references
1. Doorn, P. F. et al. Metal wear particle characterization from metal-on-metal total hip replacements: transmission electron microscopy study of periprosthetic tissues and isolated particles. J. Biomed. Mater. Res. 42, 103–111 (1998).10.1002/(SICI)1097-4636(199810)42:1<103::AID-JBM13>3.0.CO;2-M ↗
2. Ingham, E. & Fisher, J. The role of macrophages in osteolysis of total joint replacement. Biomaterials 26, 1271–1286 (2005).10.1016/j.biomaterials.2004.04.035 ↗
3. Veronesi, F., Tschon, M. & Fini, M. Gene expression in osteolysis: review on the identification of altered molecular pathways in preclinical and clinical studies. Int. J. Mol. Sci. 18, 499 (2017).10.3390/ijms18030499 ↗
4. Ulrich, S. D. et al. Total hip arthroplasties: What are the reasons for revision? Int. Orthop. 32, 597–604 (2008).10.1007/s00264-007-0364-3 ↗
5. Catelas, I. et al. Size, shape, and composition of wear particles from metal-metal hip simulator testing: effects of alloy and number of loading cycles. J. Biomed. Mater. Res. A 67, 312–327 (2003).10.1002/jbm.a.10088 ↗
6. Konttinen, Y. T. & Pajarinen, J. Surgery: Adverse reactions to metal-on-metal implants. Nat. Rev. Rheumatol. 9, 5–6 (2013).10.1038/nrrheum.2012.218 ↗
7. Delaunay, C., Petit, I., Learmonth, I. D., Oger, P. & Vendittoli, P. A. Metal-on-metal bearings total hip arthroplasty: The cobalt and chromium ions release concern. Orthop. Traumatol. Surg. Res. 96, 894–904 (2010).10.1016/j.otsr.2010.05.008 ↗
8. Goode, A. E. et al. Chemical speciation of nanoparticles surrounding metal-on-metal hips. Chem. Commun. 48, 8335 (2012).10.1039/c2cc33016d ↗
9. Case, C. P. et al. Widespread dissemination of metal debris from implants. J. Bone Jt. Surg. Br. 76, 701–712 (1994).10.2106/00004623-199405000-00011 ↗
10. Urban, R. M., Tomlinson, M. J., Hall, D. J. & Jacobs, J. J. Accumulation in liver and spleen of metal particles generated at nonbearing surfaces in hip arthroplasty. J. Arthroplast. 19, 94–101 (2004).10.1016/j.arth.2004.09.013 ↗
11. Huber, M., Reinisch, G., Trettenhahn, G., Zweymüller, K. & Lintner, F. Presence of corrosion products and hypersensitivity-associated reactions in periprosthetic tissue after aseptic loosening of total hip replacements with metal bearing surfaces. Acta Biomater. 5, 172–180 (2009).10.1016/j.actbio.2008.07.032 ↗
12. Catelas, I., Campbell, P. A., Bobyn, J. D., Medley, J. B. & Huk, O. L. Wear particles from metal-on-metal total hip replacements: effects of implant design and implantation time. Proc. Inst. Mech. Eng. Part H. J. Eng. Med. 220, 195–208 (2006).10.1243/09544119JEIM112 ↗
13. Hart, A. J. et al. Microfocus study of metal distribution and speciation in tissue extracted from revised metal on metal hip implants. J. Phys. Conf. Ser. 190, 12208 (2009).10.1088/1742-6596/190/1/012208 ↗
14. Kwon, Y.-M. et al. Dose-dependent cytotoxicity of clinically relevant cobalt nanoparticles and ions on macrophages in vitro. Biomed. Mater. 4, 25018 (2009).10.1088/1748-6041/4/2/025018 ↗
15. Papageorgiou, I. et al. Genotoxic effects of particles of surgical cobalt chrome alloy on human cells of different age in vitro. Mutat. Res. - Fundam. Mol. Mech. Mutagen. 619, 45–58 (2007).10.1016/j.mrfmmm.2007.01.008 ↗
16. Gill, H. S., Grammatopoulos, G., Adshead, S., Tsialogiannis, E. & Tsiridis, E. Molecular and immune toxicity of CoCr nanoparticles in MoM hip arthroplasty. Trends Mol. Med. 18, 145–155 (2012).10.1016/j.molmed.2011.12.002 ↗
17. Simoes, T. A. et al. Evidence for the dissolution of molybdenum during tribocorrosion of CoCrMo hip implants in the presence of serum protein. Acta Biomater. 45, 410–418 (2016).10.1016/j.actbio.2016.08.051 ↗
18. Hodgson, A. W. E. et al. Passive and transpassive behaviour of CoCrMo in simulated biological solutions. Electrochim. Acta 49, 2167–2178 (2004).10.1016/j.electacta.2003.12.043 ↗
19. Bozic, K. J. et al. The Epidemiology of Revision Total Hip Arthroplasty in the United States. J. Bone Jt. Surg. 91, 128–133 (2009).10.2106/JBJS.H.00155 ↗
20. Khan, M. A., Williams, R. L. & Williams, D. F. In-vitro corrosion and wear of titanium alloys in the biological environment. Biomaterials 17, 2117–2126 (1996).10.1016/0142-9612(96)00029-4 ↗
21. Mabilleau, G. et al. Influence of fluoride, hydrogen peroxide and lactic acid on the corrosion resistance of commercially pure titanium. Acta Biomater. 2, 121–129 (2006).10.1016/j.actbio.2005.09.004 ↗
22. Valero Vidal, C. & Igual Muñoz, A. Electrochemical characterisation of biomedical alloys for surgical implants in simulated body fluids. Corros. Sci. 50, 1954–1961 (2008).10.1016/j.corsci.2008.04.002 ↗
23. Erlebacher, J., Aziz, M. J., Karma, A., Dimitrov, N. & Sieradzki, K. Evolution of nanoporosity in dealloying. Nature 410, 450–453 (2001).10.1038/35068529 ↗
24. Schofield, E. J., Ingham, B., Turnbull, A., Toney, M. F. & Ryan, M. P. Strain development in nanoporous metallic foils formed by dealloying. Appl. Phys. Lett. 92, 1–4 (2008).10.1063/1.2838351 ↗
25. Simoes, T. A. et al. Microstructural characterization of low and high carbon CoCrMo alloy nanoparticles produced by mechanical milling. J. Phys. Conf. Ser. 522, 12059 (2014).10.1088/1742-6596/522/1/012059 ↗
26. Kerkar, M., Robinson, J. & Forty, aJ. In situ structural studies of the passive film on iron and iron/chromium alloys using X-ray absorption spectroscopy. Faraday Discuss. Chem. Soc. 89, 31–40 (1990).10.1039/dc9908900031 ↗
27. Tay, S. E. R. et al. Direct in situ observation of ZnO nucleation and growth via transmission X-ray microscopy. Nanoscale 8, 1849–1853 (2016).10.1039/C5NR07019H ↗