journal article·2026-01-28Open access

Directional permeation-driven microfiber composite hydrogel towards rapid sweat uptaking and hydration monitoring

Hao Shen, Siyuan Liu, Mengyuan Liu, Yujie Liu, Feng Wen, Mingxu Wang, Yongfeng Wang, Qiang Gao, Lianhui Li, Dengfeng Zhou, Zuoping Xiong, Shuqi Wang, Ting Zhang

npj Flexible Electronics· Volume 10· Issue 1

Abstract

Wearable sweat rate and electrolyte sensors offer real-time assessment of hydration status. Current epidermal microfluidic devices represent the widely adopted approach; however, their limitation for microliter-scale sweat collection often results in response latency and compromised detection accuracy. A rapid sweat-absorbing material (RSAM) filled in the collection chamber between the microfluidic device and the skin has been demonstrated as an effective solution. This work proposes a polyvinyl alcohol@polyurethane microfiber composite hydrogel (PVA@PU MH) with unidirectional sweat-transport capability in the inlet chamber of a microfluidic. The optimized PVA@PU MH exhibits a sweat collection efficiency that is 49.76 ± 6.75% higher than traditional methods. With anisotropic microchannels, PVA@PU MH leverages capillary action to confine sweat laterally and drive vertical transport directionally. Additionally, the integration of conductivity-sensing components within the microfluidic system enables the detection of both sweat rate and electrolyte concentration. A low-power unit was developed to process and wirelessly transmit real-time sweat data to mobile devices for continuous monitoring. The PVA@PU MH facilitated both faster sweat uptake and more physiologically representative analyte readings, as evidenced by a strong correlation with whole-body measurements. The proposed strategy rapidly acquires microliter sweat samples, substantially expanding wearable monitoring capabilities.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Advanced Sensor and Energy Harvesting Materials · 3D Printing in Biomedical Research · Hydrogels: synthesis, properties, applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (39)

Show source-provided references
1. Bariya, M., Nyein, H. Y. Y. & Javey, A. Wearable sweat sensors. Nat. Electron. 1, 160–171 (2018).10.1038/s41928-018-0043-y ↗
2. Brasier, N. et al. The potential of wearable sweat sensors in heart failure management. Nat. Electron. 7, 182–184 (2024).10.1038/s41928-024-01136-w ↗
3. Yang, D. S., Ghaffari, R. & Rogers, J. A. Sweat as a diagnostic biofluid. Science 379, 760–761 (2023).10.1126/science.abq5916 ↗
4. Cinca-Morros, S., Garcia-Rey, S., Álvarez-Herms, J., Basabe-Desmonts, L. & Benito-Lopez, F. A physiological perspective of the relevance of sweat biomarkers and their detection by wearable microfluidic technology: a review. Anal. Chim. Acta 1327, 342988 (2024).10.1016/j.aca.2024.342988 ↗
5. Liu, M. et al. Adaptively resettable microfluidic patch for sweat rate and electrolytes detection. Biosens. Bioelectron. 257, 116299 (2024).10.1016/j.bios.2024.116299 ↗
6. Liu, M. et al. Perspiration permeable, textile embeddable microfluidic sweat sensor. Biosens. Bioelectron. 237, 115504 (2023).10.1016/j.bios.2023.115504 ↗
7. Wang, S. et al. An unconventional vertical fluidic-controlled wearable platform for synchronously detecting sweat rate and electrolyte concentration. Biosens. Bioelectron. 210, 114351 (2022).10.1016/j.bios.2022.114351 ↗
8. Clausen, D. et al. Wearable continuous diffusion-based skin gas analysis. Nat. Commun. 16, 4343 (2025).10.1038/s41467-025-59629-x ↗
9. Liu, C., Xu, T., Wang, D. & Zhang, X. The role of sampling in wearable sweat sensors. Talanta 212, 120801 (2020).10.1016/j.talanta.2020.120801 ↗
10. Brasier, N. et al. The molecular signature of heat stress in sweat reveals non-invasive biomarker candidates for health monitoring. Commun. Biol. 8, 650 (2025).10.1038/s42003-025-08080-1 ↗
11. Zhang, T., Kabandana, G. K. M., Terrell, J. A., Chen, H. & Chen, C. Recent advances in wearable sweat sensor development. Wiley Interdiscip. Rev. Nanomed. Nanobiotechnol. 17, e70006 (2025).10.1002/wnan.70006 ↗
12. Kim, S. R. et al. Electrodermal activity as a proxy for sweat rate monitoring during physical and mental activities. Nat. Electron. 8, 353–361 (2025).10.1038/s41928-025-01365-7 ↗
13. Kim, J. et al. A skin-interfaced, miniaturized microfluidic analysis and delivery system for colorimetric measurements of nutrients in sweat and supply of vitamins through the skin. Adv. Sci. 9, 2103331 (2022).10.1002/advs.202103331 ↗
14. Tu, J. et al. A wireless patch for the monitoring of C-reactive protein in sweat. Nat. Biomed. Eng. 7, 1293–1306 (2023).10.1038/s41551-023-01059-5 ↗
15. Choi, J. et al. Skin-Interfaced microfluidic systems that combine hard and soft materials for demanding applications in sweat capture and analysis. Adv. Healthc. Mater. 10, 200722 (2021).10.1002/adhm.202000722 ↗
16. Bandodkar, A. J. et al. Battery-free, skin-interfaced microfluidic/electronic systems for simultaneous electrochemical, colorimetric, and volumetric analysis of sweat. Sci. Adv. 5, eaav3294 (2019).10.1126/sciadv.aav3294 ↗
17. Yang, Y. et al. Wearable microfluidics: fabric-based digital droplet flowmetry for perspiration analysis. Lab Chip 17, 926–935 (2017).10.1039/C6LC01522K ↗
18. Kwon, K. et al. An on-skin platform for wireless monitoring of flow rate, cumulative loss and temperature of sweat in real time. Nat. Electron. 4, 302–312 (2021).10.1038/s41928-021-00556-2 ↗
19. Dautta, M. et al. Tape-Free, digital wearable band for exercise sweat rate monitoring. Adv. Mater. Technol. 8, 2201187 (2023).10.1002/admt.202201187 ↗
20. Baker, L. B. et al. Skin-Interfaced microfluidic system with personalized sweating rate and sweat chloride analytics for sports science applications. Sci. Adv. 6, eabe3929 (2020).10.1126/sciadv.abe3929 ↗
21. Nelson, R. S. et al. Remote analysis and management of sweat biomarkers using a wearable microfluidic sticker in adult cystic fibrosis patients. Proc. Natl. Acad. Sci. USA 122, e2506137122 (2025).10.1073/pnas.2506137122 ↗
22. Bariya, M. et al. Resettable microfluidics for broad-range and prolonged sweat rate sensing. ACS Sens. 7, 1156–1164 (2022).10.1021/acssensors.2c00177 ↗
23. Ding, H., Yang, H. & Tsujimura, S. Nature-Inspired superhydrophilic biosponge as structural beneficial platform for sweating analysis patch. Adv. Sci. 11, e2401947 (2024).10.1002/advs.202401947 ↗
24. Liu, J., Xu, Z., Wang, H., Zhao, Y. & Lin, T. Directional liquid transport in thin fibrous matrices: Enhancement of advanced applications. ACS Nano 19, 5913–5937 (2025).10.1021/acsnano.4c17351 ↗
25. Li, D. et al. Janus textile: advancing wearable technology for autonomous sweat management and beyond. Small 21, 2409730 (2025).10.1002/smll.202409730 ↗
26. Zhang, S., Tan, R., Xu, X., Iqbal, S. & Hu, J. Fibers/textiles-based flexible sweat sensors: a review. ACS Mater. Lett. 5, 1420–1440 (2023).10.1021/acsmaterialslett.2c01207 ↗
27. Lin, P. H., Sheu, S. C., Chen, C. W., Huang, S. C. & Li, B. R. Wearable hydrogel patch with noninvasive, electrochemical glucose sensor for natural sweat detection. Talanta 241, 123187 (2022).10.1016/j.talanta.2021.123187 ↗
28. Lu, L. et al. Sweat-Sensing patches with integrated hydrogel interface for resting sweat collection and multi-information detection. Biosensors 15, 342 (2025).10.3390/bios15060342 ↗
29. Lin, S. et al. Natural perspiration sampling and in situ electrochemical analysis with hydrogel micropatches for user-identifiable and wireless chemo/biosensing. ACS Sens. 5, 93–102 (2020).10.1021/acssensors.9b01727 ↗
30. Nyein, H. Y. Y. et al. A wearable patch for continuous analysis of thermoregulatory sweat at rest. Nat. Commun. 12, 1823 (2021).10.1038/s41467-021-22109-z ↗
31. Shen, H. et al. Multi-Bioinspired droplet self-actuated sweat transport platform for continuous wearable biochemical monitoring. Adv. Mater. Technol. 9, 2301803 (2024).10.1002/admt.202301803 ↗
32. Son, J. et al. Cactus-Spine-Inspired sweat-collecting patch for fast and continuous monitoring of sweat. Adv. Mat. 33, 2102740 (2021).10.1002/adma.202102740 ↗
33. Shin, S. et al. A bioinspired microfluidic wearable sensor for multiday sweat sampling, transport, and metabolic analysis. Sci. Adv. 11, eadw9024 (2025).10.1126/sciadv.adw9024 ↗
34. Gao, Q. et al. Biological tissue-inspired ultrasoft, ultrathin, and mechanically enhanced microfiber composite hydrogel for flexible bioelectronics. Nanomicro. Lett. 15, 139 (2023).
35. Liang, J. et al. Bioinspired mechanically robust and recyclable hydrogel microfibers based on hydrogen-bond nanoclusters. Adv. Sci. 11, 2401278 (2024).10.1002/advs.202401278 ↗
36. Lazanas, A. C. & Prodromidis, M. I. Electrochemical impedance spectroscopy─a tutorial. ACS Meas. Sci. Au 3, 162–193 (2023).10.1021/acsmeasuresciau.2c00070 ↗
37. Smith, C. J. & Havenith, G. Body mapping of sweating patterns in male athletes in mild exercise-induced hyperthermia. Eur. J. Appl. Physiol. 111, 1391–1404 (2011).10.1007/s00421-010-1744-8 ↗
38. Smith, C. J. & Havenith, G. Body mapping of sweating patterns in athletes: a sex comparison. Med. Sci. Sports Exerc. 44, 2350–2361 (2012).10.1249/MSS.0b013e318267b0c4 ↗
39. Yamada, Y. et al. Variation in human water turnover associated with environmental and lifestyle factors. Science 378, 909–915 (2022).10.1126/science.abm8668 ↗