journal article·2023-10-17Open access

Skin-integrated, biocompatible, and stretchable silicon microneedle electrode for long-term EMG monitoring in motion scenario

Huawei Ji, Mingyu Wang, Yutong Wang, Zhouheng Wang, Yinji Ma, Lanlan Liu, Honglei Zhou, Ze Xu, Xian Wang, Ying Chen, Xue Feng

npj Flexible Electronics· Volume 7· Issue 1

Abstract

Abstract Electromyography (EMG) signal is the electrical potential generated by contracting muscle cells. Long-term and accurate EMG monitoring is desirable for neuromuscular function assessment in clinical and the human–computer interfaces. Herein, we report a skin-integrated, biocompatible, and stretchable silicon microneedle electrode (SSME) inspired by the plant thorns. The silicon microneedles are half encapsulated by the polyimide (PI) to enhance the adaptability to deformation and resistance to fatigue. Thorn-like SSME is realized by the semi-additive method with a stretchability of not less than 36%. The biocompatibility of SSME has been verified using cytotoxicity tests. EMG monitoring in motion and long-term has been conducted to demonstrate the feasibility and performance of the SSME, which is compared with a commercial wet electrode. Hopefully, the strategies reported here can lead to accurate and long-term EMG monitoring, facilitating an effective and reliable human–computer interface.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Advanced Sensor and Energy Harvesting Materials · Muscle activation and electromyography studies · Neuroscience and Neural Engineering

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (44)

Show source-provided references
1. Mahmood, M. et al. VR-enabled portable brain-computer interfaces via wireless soft bioelectronics. Biosens. Bioelectron. 210, 114333 (2022).10.1016/j.bios.2022.114333 ↗
2. Kim, D.-H. et al. Epidermal electronics. Science 333, 838–843 (2011).10.1126/science.1206157 ↗
3. Chen, Y. et al. Flexible inorganic bioelectronics. NPJ Flex. Electron 4, 1–20 (2020).10.1038/s41528-020-0065-1 ↗
4. Lee, H. et al. A graphene-based electrochemical device with thermoresponsive microneedles for diabetes monitoring and therapy. Nat. Nanotechnol. 11, 566–572 (2016).10.1038/nnano.2016.38 ↗
5. Yu, J., Zhang, K. & Deng, Y. Recent progress in pressure and temperature tactile sensors: principle, classification, integration and outlook. Soft Sci. 1, 6 (2021).
6. Wong, T. H. et al. Tattoo-like epidermal electronics as skin sensors for human-machine interfaces. Soft Sci. 1, 10 (2021).
7. Du, Q. et al. High‐performance flexible pressure sensor based on controllable hierarchical microstructures by laser scribing for wearable electronics. Adv. Mater. Technol. 6, 2100122 (2021).10.1002/admt.202100122 ↗
8. Chen, Y., Lu, B., Chen, Y. & Feng, X. Breathable and stretchable temperature sensors inspired by skin. Sci. Rep. 5, 1–11 (2015).
9. Zhao, W., Liu, L., Lan, X., Leng, J. & Liu, Y. Thermomechanical constitutive models of shape memory polymers and their composites. Appl. Mech. Rev. 75, 020802 (2022).10.1115/1.4056131 ↗
10. Ahsan, M. R., Ibrahimy, M. I. & Khalifa, O. O. EMG signal classification for human computer interaction: a review. Eur. J. Sci. Res. 33, 480–501 (2009).
11. Chi, Y. M., Jung, T.-P. & Cauwenberghs, G. Dry-contact and noncontact biopotential electrodes: Methodological review. IEEE Rev. Biomed. Eng. 3, 106–119 (2010).10.1109/RBME.2010.2084078 ↗
12. Ren, L., Liu, B., Zhou, W. & Jiang, L. A mini review of microneedle array electrode for bio-signal recording: a review. IEEE Sens. J. 20, 577–590 (2019).10.1109/JSEN.2019.2944847 ↗
13. Losey, D., Mcdonald, C., Battaglia, E. & O“Malley, M. K. A review of intent detection, arbitration, and communication aspects of shared control for physical human–robot interaction. Appl. Mech. Rev. 70, 010804 (2018).10.1115/1.4039145 ↗
14. Farina, D., Merletti, R. & Enoka, R. M. The extraction of neural strategies from the surface EMG. J. Appl. Physiol. 96, 1486–1495 (2004).10.1152/japplphysiol.01070.2003 ↗
15. Avenel‐Audran, M., Goossens, A., Zimerson, E. & Bruze, M. Contact dermatitis from electrocardiograph‐monitoring electrodes: role of p‐tert‐butylphenol‐formaldehyde resin. Contact Derm. 48, 108–111 (2003).10.1034/j.1600-0536.2003.480210.x ↗
16. Jelen, G. Acrylate, a hidden allergen of electrocardiogram electrodes. Contact Derm. 45, 315–316 (2001).10.1034/j.1600-0536.2001.450522.x ↗
17. Merletti, R. The electrode–skin interface and optimal detection of bioelectric signals. Physiol. Meas. 31, E01 (2010).10.1088/0967-3334/31/10/E01 ↗
18. Searle, A. & Kirkup, L. A direct comparison of wet, dry and insulating bioelectric recording electrodes. Physiol. Meas. 21, 271 (2000).10.1088/0967-3334/21/2/307 ↗
19. Inoh, T. et al. Nanofiber web textile dry electrodes for long-term biopotential recording. IEEE Trans. Biomed. Circuits Syst. 7, 204–211 (2013).10.1109/TBCAS.2012.2201154 ↗
20. Lepola, P. et al. Screen-printed EEG electrode set for emergency use. Sens. Actuators A Phys. 213, 19–26 (2014).10.1016/j.sna.2014.03.029 ↗
21. Baek, J. Y., An, J. H., Choi, J. M., Park, K. S. & Lee, S. H. J. S. Flexible polymeric dry electrodes for the long-term monitoring of ECG. Sens. Actuators A Phys. 143, 423–429 (2008).10.1016/j.sna.2007.11.019 ↗
22. Lu, F. et al. Review of stratum corneum impedance measurement in non-invasive penetration application. Biosensors 8, 31 (2018).10.3390/bios8020031 ↗
23. Srivastava, A. K., Bhartia, B., Mukhopadhyay, K. & Sharma, A. Long term biopotential recording by body conformable photolithography fabricated low cost polymeric microneedle arrays. Sens. Actuators A Phys. 236, 164–172 (2015).10.1016/j.sna.2015.10.041 ↗
24. O’Mahony, C. et al. Microneedle-based electrodes with integrated through-silicon via for biopotential recording. Sens. Actuators A Phys. 186, 130–136 (2012).10.1016/j.sna.2012.04.037 ↗
25. Ali, R. et al. Transdermal microneedles—a materials perspective. AAPS PharmSciTech 21, 1–14 (2020).10.1208/s12249-019-1560-3 ↗
26. Fu, Y., Zhao, J., Dong, Y. & Wang, X. Dry electrodes for human bioelectrical signal monitoring. Sensors 20, 3651 (2020).10.3390/s20133651 ↗
27. Lee, W. et al. Conformable microneedle pH sensors via the integration of two different siloxane polymers for mapping peripheral artery disease. Sci. Adv. 7, eabi6290 (2021).10.1126/sciadv.abi6290 ↗
28. Krieger, K. J. et al. Development and Evaluation of 3D-Printed Dry Microneedle Electrodes for Surface Electromyography. Adv. Mater. Technol. 5, 2000518 (2020).10.1002/admt.202000518 ↗
29. Guvanasen, G. S. et al. A stretchable microneedle electrode array for stimulating and measuring intramuscular electromyographic activity. IEEE Trans. Neural Syst. Rehabilitation Eng. 25, 1440–1452 (2016).10.1109/TNSRE.2016.2629461 ↗
30. Kim, M., Kim, T., Kim, D. S. & Chung, W. K. Curved microneedle array-based sEMG electrode for robust long-term measurements and high selectivity. Sensors 15, 16265–16280 (2015).10.3390/s150716265 ↗
31. Wang, Z., Li, J., Yu, B., Huang, D. & Li, Z. in 2022 IEEE 35th International Conference on Micro Electro Mechanical Systems Conference (MEMS). 345–348 (IEEE, 2022).10.1109/MEMS51670.2022.9699517 ↗
32. Wang, R., Jiang, X., Wang, W. & Li, Z. A microneedle electrode array on flexible substrate for long-term EEG monitoring. Sensor Actuat. B-Chem. 244, 750–758 (2017).10.1016/j.snb.2017.01.052 ↗
33. Pawlaczyk, M., Lelonkiewicz, M. & Wieczorowski, M. Age-dependent biomechanical properties of the skin. Postepy Dermatol. Allergol. 30, 302–306 (2013).10.5114/pdia.2013.38359 ↗
34. Gong, S., Yap, L. W., Zhu, B. & Cheng, W. Multiscale soft–hard interface design for flexible hybrid electronics. Adv. Mater. 32, 1902278 (2020).10.1002/adma.201902278 ↗
35. Li, R., Li, M., Su, Y., Song, J. & Ni, X. An analytical mechanics model for the island-bridge structure of stretchable electronics. Soft Matter 9, 8476–8482 (2013).10.1039/c3sm51476e ↗
36. Swanson, D. K. & Webster, J. G. A Model for Skin-electrode Impedance. 117–128 (Academic Press, 1974).
37. Xiangqing, K., Chengwei, W. U. & Ping, Z. Numerical simulation of the process of inserting micro-needles into skin. Sci. Technol. Rev. 27, 43–48 (2009).
38. Gardner, T. N. & Briggs, G. A. D. Biomechanical measurements in microscopically thin stratum corneum using acoustics. Ski. Res. Technol. 7, 254–261 (2010).10.1034/j.1600-0846.2001.70408.x ↗
39. Elkhyat, A., Courderot-Masuyer, C., Gharbi, T. & Humbert, P. Influence of the hydrophobic and hydrophilic characteristics of sliding and slidersurfaces on friction coefficient: in vivo human skin friction comparison. Ski. Res. Technol. 10, 215–221 (2010).10.1111/j.1600-0846.2004.00085.x ↗
40. Wang, L. et al. Biomechanical study on implantable and interventional medical devices. Acta Mech. Sin. 37, 21 (2021).10.1007/s10409-021-01116-9 ↗
41. International Organization for Standardization (ISO). ISO 10993-5:2009: Biological Evaluation of Medical Devices-Part 5: Tests for in Vitro Cytotoxicity. Geneve, Switzerland: ISO; (2009).
42. Canal, M. R. Comparison of wavelet and short time Fourier transform methods in the analysis of EMG signals. J. Med. Syst. 34, 91–94 (2010).10.1007/s10916-008-9219-8 ↗
43. Auchincloss, C. C. & McLean, L. The reliability of surface EMG recorded from the pelvic floor muscles. J. Neurosci. Methods 182, 85–96 (2009).10.1016/j.jneumeth.2009.05.027 ↗
44. Yamaguchi, T., Mikami, S. & Okada, K. Validity of a newly developed ultraminiature cordless EMG measurement system. Oral. Surg. Oral. Med Oral. Pathol. Oral. Radio. 104, e22–e27 (2007).10.1016/j.tripleo.2007.05.023 ↗