journal article·2009-09

Stretched zone width and blunting line equation for determination of initiation fracture toughness in low carbon highly ductile steels

Sandeep Bansal, S. K. Nath, P. K. Ghosh, S. Ray

International Journal of Fracture· Volume 159· Issue 1
Publisher page

Abstract

The methods of measurement of stretched zone width (SZW) have been examined and its relative insensitivity to thickness and length of pre-fatigue crack in CT specimens, encourages its use to mark the end of blunting in the J–R curve. On the basis of SZW, a mathematical equation has been determined for the slope of blunting line, also as a function of strain hardening coefficient, in the limited context of SA333 Gr. 6 steel and HSLA steel. The internal consistency of the 0.2 mm offset blunting line equation has been demonstrated by comparing the estimated and the observed initiation fracture toughness. The equation has been validated also with the results from literature. The initiation fracture toughness obtained for SA333 Gr. 6 steel following 0.2 mm offset line equation determined here compares well with the results reported in earlier investigations.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fatigue and fracture mechanics · Material Properties and Failure Mechanisms · High Temperature Alloys and Creep

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (28)

Show source-provided references
1. Amouzouvi KF, Bassim MN (1982) Determination of fracture toughness from stretch zone width measurement in predeformed AISI type 4340 steel. Mater Sci Eng 55: 257–26210.1016/0025-5416(82)90139-2 ↗
2. ASTM E813 (1995) Standard test method for J Ic, a measure of fracture toughness. Annu Book of ASTM Stand 03.01
3. ASTM E1820 (2001) Standard test method for J-integral characterization of fracture toughness. American Society for Testing and Materials, Philadelphia
4. Bassim MN, Matthews JR, Hyatt CV (1992) Evaluation of fracture toughness of HSLA80 steel at high loading rates using stretch zone measurements. Eng Fract Mech 43: 297–30310.1016/0013-7944(92)90128-2 ↗
5. Betegon C, Hancock JW (1991) Two parameter characterization of elastic-plastic crack-tip fields. J Appl Mech 58: 104–11010.1115/1.2897135 ↗
6. Chao YJ, Yang S, Sutton MA (1994) On the fracture of solids characterized by one or two parameters: theory and practice. J Mech Phys Solids 42: 629–64710.1016/0022-5096(94)90055-8 ↗
7. Doig P, Smith RF, Flewitt PEJ (1984) The use of stretch zone width measurements in the determination of fracture toughness of low strength steels. Eng Fract Mech 19: 653–66410.1016/0013-7944(84)90098-5 ↗
8. ESIS P1-92 (1992) ESIS recommendations for determining the fracture resistance of ductile materials. ESIS office, University of Technology, Delft, The Netherlands
9. ESIS P2-92 (1992) ESIS procedure for determining the fracture behaviour of materials: ESIS P2-92. European Structural Integrity Society, Delft, The Netherlands
10. Instron Fast Track Software J IC Fracture Toughness Program 32-bit Version, M22-10019-EN (1998)
11. Kobayashi H, Hirano K, Nakamura H, Nakazawa H (1977) Fracture. ICF4, Waterloo, pp 583–592
12. Kolednik O, Stüwe HP (1986) An extensive analysis of a J IC-test. Eng Fract Mech 24: 277–29010.1016/0013-7944(86)90058-5 ↗
13. Landes JD, Begley JA (1974) American society for tTesting and materials STP-560. pp 170–186
14. Mills WJ (1981) On the relationship between stretch zone formation and J-integral for high strain hardening materials. J Test Eval 9: 56–6210.1520/JTE10648J ↗
15. O’Dowd NP, Shih CF (1991) Family of crack-tip fields characterized by a triaxiality parameter-I. Structure of fields. J Mech Phys Solids 39: 989–101510.1016/0022-5096(91)90049-T ↗
16. O’Dowd NP, Shih CF (1992) Family of crack-tip fields characterized by a triaxiality parameter—II. Fracture applications. J Mech Phys Solids 40: 939–96310.1016/0022-5096(92)90057-9 ↗
17. O’Dowd NP, Shih CF (1994) Fracture mechanics: twenty-fourth volume, ASTM STP 1207. American Society for Testing and Materials, Philadelphia, pp 21–4710.1520/STP13698S ↗
18. Ohji K, Ogura K, Mutoh Y, Itogawa H, Uchida H, Honki M (1978) Observations of crack initiation and stable growth processes in fracture toughness testing of several steels. J Mater Sci Soc Jpn 27: 3110.2472/jsms.27.31 ↗
19. Putatunda SK, Rigsbee JM (1985) Influence of specimen size on the crack-opening stretch zone. Mater Sci Eng 70: 111–12210.1016/0025-5416(85)90272-1 ↗
20. Rice JR (1968) Path independent integral and the approximate analysis of strain concentration by notches and cracks. J Appl Mech 35: 379–38610.1115/1.3601206 ↗
21. Roos E, Eisels U, Silcher H, Eckert W (1991). In: Kussmaul K (eds) Fracture mechanics verification by large-scale testing, EGF/ESIS8. pp 65–85
22. Schwalbe KH, Hayes B, Baustian K, Cornec A, Gordon R, Homayun M, Voss B (1993) Validation of the fracture mechanics test method EGF P1-87D (ESIS P1-90/ESIS P1-92). Fatigue Fract Eng Mater Struct 16: 1231–128410.1111/j.1460-2695.1993.tb00736.x ↗
23. Shen G, Xu S, Tyson WR (2001) Defence R & D Canada, contract report, DREA CR 2001-091. Defence Research Establishment Atlantic
24. Singh PK, Chattopadhyay J, Kushwaha HS, Tarafder S, Ranganath VR (1998) Tensile and fracture properties evaluation of PHT system piping material of PHWR. Int J Press Vessels Piping 75: 271–28010.1016/S0308-0161(97)00093-8 ↗
25. Srinivas M, Kamat SV, Rao PR (1994) A fractographic technique for the estimation of initiation fracture toughness J Ic for ductile materials. J Test Eval 22: 302–30810.1520/JTE11838J ↗
26. Tarafder S, Ranganath VR, Sivaprasad S, Johri P (2003) Ductile fracture behaviour of primary heat transport piping material of nuclear reactors. Sadhana 28: 167–18610.1007/BF02717132 ↗
27. Yang S, Chao YJ, Sutton MA (1993) Higher order asymptotic crack tip fields in a power-law hardening material. Eng Fract Mech 45: 1–2010.1016/0013-7944(93)90002-A ↗
28. Yin SW, Gerbrands RA, Hartevelt M (1983) An investigation of the blunting line. Eng Fract Mech 18: 1025–103610.1016/0013-7944(83)90074-7 ↗