Fatigue failure in the cement mantle of a simplified acetabular replacement model
Source abstract
Abstract
Although the role of fatigue failure in aseptic loosening of cemented total hip replacements has been extensively studied in femoral components, studies of fatigue failure in cement mantle of acetabular replacements have yet to be reported, despite that the long-term failure rate in the latter is about three times that of femoral components. Part of the reason may be that a complex pelvic bone structure does not land itself readily for a 2D representation as that of a femur.In this work, a simple multilayer model has been developed to reproduce the stress distributions in the cement mantle of an acetabular replacement from a plane strain finite element pelvic bone model. The experimental multilayer model was subjected to cyclic loading up to peak hip contact force during normal walking. Radial fatigue cracks were observed in the vicinity of the maximum tangential and compressive stresses, as predicted by the FE models. Typical fatigue striations were also observed on the fracture surfaces post cyclic testing. The results were examined in the context of retrieval studies, 3D FE analysis and in vitro experimental results using full-sized hemi-pelvic bone models.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Orthopedic Infections and Treatments · Total Knee Arthroplasty Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (25)
Show source-provided references
1. Poor outcome of the PCA and Harris-Galante hip prostheses: randomized study of 171 arthroplasties with 9-year follow-up10.3109/17453679909011255 ↗
2. Acetabular cup migration10.1302/0301-620X.77B6.7593094 ↗
3. Biomechanical and histologic investigation of cemented total hip arthroplasties10.1097/00003086-198912000-00015 ↗
4. A fractographic analysis of in vivo poly(methylmethacrylate) bone cement failure mechanisms10.1002/jbm.820240202 ↗
5. The initiation of failure in cemented femoral components of hip arthroplasties10.1302/0301-620X.73B4.2071634 ↗
6. Fatigue failure in the cement of an artificial hip joint10.1016/0267-6605(93)90056-D ↗
7. An experimental study of damage accumulation in cemented hip prostheses10.1016/0268-0033(95)00076-3 ↗
8. Microdamage accumulation in the cement layer of hip replacements under flexural loading10.1016/S0021-9290(99)00018-4 ↗
9. Cement microcracks in thin-mantle regions after in vitro fatigue loading10.1016/j.arth.2003.12.080 ↗
10. Finite element simulation of anisotropic damage accumulation and creep in acrylic bone cement10.1016/S0013-7944(03)00048-1 ↗
11. Fatigue analysis of cemented hip prosthesis: damage accumulation scenario and sensitivity analysis10.1016/S0142-1123(01)00204-3 ↗
12. Computer simulation on fatigue behaviour of cemented hip prostheses: a physiological model10.1016/j.cmpb.2004.05.004 ↗
13. Failed innovation in total hip replacement10.3109/17453679308994602 ↗
14. The outcome of Charnley total hip arthroplasty with cement after a minimum twenty-year follow-up. The results of one surgeon10.2106/00004623-199307000-00002 ↗
15. Huiskes R, Stolk J. Biomechanics and preclinical testing of artificial joints: the hip. In: Basic orthopaedic biomechanics and mechano-biology. Lippincott Williams & Wilkins, Philadelphia, USA.
16. Contact finite element stress analysis of the hip joint10.1002/jor.1100030406 ↗
17. Finite element modelling – predictor of implant survival?
18. Analysis of contact mechanics in ceramic-on-ceramic hip joint replacements10.1243/09544110260138718 ↗
19. contact forces and gait patterns from routine activities10.1016/S0021-9290(01)00040-9 ↗
20. Fatigue properties of acrylic bone cements: review of the literature10.1002/jbm.b.10018 ↗
21. Fatigue testing and performance of acrylic bone–cement materials: state-of-art review
22. Early cement damage around a femoral stem is concentrated at the cement/bone interface10.1016/S0021-9290(02)00460-8 ↗
23. On fatigue lifetimes and fatigue crack growth behaviour of bone cement
24. Hong T, Wang J-Y, Zant NP, Heaton-Adegbile P, Hussell JG, Tong J. A comparison of 2D and 3D acetabular models in the assessment of fatigue integrity of cement fixation. Unpublished work.
25. In-vitro fatigue behaviour of a cemented acetabular reconstruction10.1016/j.jbiomech.2005.10.010 ↗