journal article·2014-11

Monitoring the damage evolution of flexural fatigue in unidirectional carbon/carbon composites by electrical resistance change method

Li-Zhen Xue, Ke-Zhi Li, Shou-Yang Zhang, He-Jun Li, Jing Cheng, Wen-Fei Luo

Publisher page

Abstract

Abstract This paper reported simultaneous monitoring damage evolution of flexural fatigue in unidirectional carbon-fiber-reinforced carbon composites (C/C composites) by electrical resistance change (ERC) methods. The degree of irregularity in electrical resistance changes increased with stress levels increasing. The shapes of electrical resistance change rate–fatigue cycle curves can reflect stress levels and damage types of tested samples: sawtooth shapes reflected delamination at a higher stress level; and “peak” shapes reflected inner damages in one fiber bundle at the fatigue limit stress level. In addition, the similarity of initial electrical resistance–fatigue life curve and S–N curve was observed clearly. In summary, ERC methods can monitor the damage evolution and qualitatively estimate the fatigue life of unidirectional C/C composites.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Smart Materials for Construction · Concrete Corrosion and Durability · Structural Health Monitoring Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (10)

Show source-provided references
1. Monitoring bending fatigue in carbon-fibre/epoxy composite strands: a comparison between mechanical and resistance techniques10.1016/S0266-3538(01)00028-8 ↗
2. On the fatigue life prediction of CFRP laminates using the electrical resistance change method10.1016/j.compscitech.2011.01.003 ↗
3. Strain and damage monitoring of CFRP laminates by means of electrical resistance measurement10.1299/jmmp.1.947 ↗
4. Damage detection using self-sensing concepts10.1243/09544100JAERO203 ↗
5. Determination of electric resistance for in situ determination of fibre failure in carbon fibre-reinforced plastic composites
6. Load and failure analyses of CFRP laminates by means of electrical resistivity measurements10.1016/0266-3538(89)90016-X ↗
7. In situ detection in CFRP laminates by electrical resistance measurements10.1016/S0266-3538(98)00132-8 ↗
8. Case · 2007 · 405
9. Material state changes as a basis for prognosis in aeronautical structures10.1017/S0001924000003444 ↗
10. Prediction of structural dynamic plastic shear failure by Johnson’s damage number10.1007/PL00010753 ↗