journal article·2006-11

Staircase testing of a titanium alloy in the gigacycle regime

R MORRISSEY, T NICHOLAS

International Journal of Fatigue· Volume 28· Issue 11
Publisher page

Abstract

Abstract The objective of this research was to investigate the high cycle fatigue behavior of a titanium alloy using an ultrasonic fatigue system. Fatigue testing from 10 6 to 10 9 cycles under fully reversed cycling ( R = −1) was performed to determine the ultra-high cycle fatigue behavior of Ti–6Al–4V. The staircase test method was employed to obtain accurate values of the mean fatigue limit stress corresponding to fixed numbers of cycles up to 10 9 . These results were compared to similar data generated on conventional servohydraulic test systems and electromagnetic shaker systems to determine if there are any frequency effects. In addition, specimens were tested with and without cooling air to determine the effects of temperature on the fatigue behavior. Results indicate that the fatigue strength determined from ultrasonic testing was consistent with conventional testing. In addition, the temperature rise in this material during ultrasonic testing is insignificant and has no apparent effect on the endurance limit.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fatigue and fracture mechanics · Hydrogen embrittlement and corrosion behaviors in metals · Microstructure and Mechanical Properties of Steels

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References

Reference metadata was not supplied for this record.