journal article·2004-12

Stop drilling procedure for fatigue life improvement

P SONG

International Journal of Fatigue· Volume 26· Issue 12
Publisher page

Abstract

Abstract This paper investigated how the stop drilling procedure improved the crack initiation life and the total fatigue life in specimens of 6061-T651 aluminium alloy and AISI 304 stainless steel. The crack initiation life was the number of fatigue cycles initiating a 0.2 mm crack at a stophole edge. The larger the stophole diameter, the longer the crack initiation and total fatigue lives. The 2, 2.5, and 3 mm diameter stopholes improved the nonstop-drilled total fatigue life of the 6061-T651 specimen by 187%, 321%, and 443% and that of the AISI 304 specimen by 72%, 121%, and 174%. At each stophole diameter, the 6061-T651 crack initiation life improved over the AISI 304 counterpart because of lower values of the K f factor and the Δ J / ρα c ratio.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fatigue and fracture mechanics · Non-Destructive Testing Techniques · Ultrasonics and Acoustic Wave Propagation

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References

Reference metadata was not supplied for this record.