journal article·2025-12-29Open access

Design and Numerical Investigation of Novel Self-Centering Precast Concrete Beam-Column Joints with Replaceable Damage-Controllable Hinges

Chunxu Hou, Gao Ma, Hyeon-Jong Hwang, Shuo Zhang, Jiaxu Miao

Abstract

Abstract To minimize the seismic damage to the beam-column joint and facilitate post-earthquake repair, an innovative precast concrete (PC) beam-column joint (SCPJ) with self-centering and damage-controllable capacities was proposed. In the proposed SCPJ, the steel connector which was made up of two splice plates and an X-shaped plate, can form a rotational hinge at the joint and can be readily replaced after seismic damage. Also, unbonded post-tensioned (PT) tendons were used as self-centering elements. A design method was first developed for SCPJ to control damage within the dog-bone-shaped steel plates (DSP) and provide a comparable load-carrying capacity to a cast-in-place (CIP) joint. Afterward, numerical models for the proposed SCPJ were established using ABAQUS. The comparison between a CIP joint and a counterpart SCPJ (namely SCPJ-1) confirmed the validity of the design method. The damage was primarily localized in the DSP, while the PC components remained almost intact. Specimen SCPJ-1 showed a 30% lower residual drift ratio at the ultimate displacement than the CIP joint, demonstrating excellent self-centering capacity. Further, the systematic parametric analysis indicated that the increase of the DSP material strength and prestress level of PT tendons substantially improved the self-centering capability. The variations of the DSP thickness, the width of weakened section of DSP, and the thickness of XSP can shift the failure from DSP to XSP or PC components.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Load-Bearing Analysis · Seismic Performance and Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (51)

Show source-provided references
1. Alavi-Dehkordi, S., Mostofinejad, D., & Alaee, P. (2019). Effects of high-strength reinforcing bars and concrete on seismic behavior of RC beam-column joints. Engineering Structures, 183, 702–719. https://doi.org/10.1016/j.engstruct.2019.01.01910.1016/j.engstruct.2019.01.019 ↗
2. Arslan, M. H., Korkmaz, H. H., & Gulay, F. G. (2006). Damage and failure pattern of prefabricated structures after major earthquakes in Turkey and shortfalls of the Turkish Earthquake code. Engineering Failure Analysis, 13(4), 537–557. https://doi.org/10.1016/j.engfailanal.2005.02.00610.1016/j.engfailanal.2005.02.006 ↗
3. A.T. Council and N.E.H.R. Program, Seismic performance assessment of buildings, Federal Emergency Management Agency 2012.
4. Bahrami, S., Madhkhan, M., Shirmohammadi, F., & Nazemi, N. (2017). Behavior of two new moment resisting precast beam to column connections subjected to lateral loading. Engineering Structures, 132, 808–821. https://doi.org/10.1016/j.engstruct.2016.11.06010.1016/j.engstruct.2016.11.060 ↗
5. Blebo, F. C., & Roke, D. A. (2018). Seismic-resistant self-centering rocking core system with buckling restrained columns. Engineering Structures, 173, 372–382. https://doi.org/10.1016/j.engstruct.2018.06.11710.1016/j.engstruct.2018.06.117 ↗
6. Fan, L., & Lv, X. (2011). Seismic response analysis of a jointed precast concrete frame structure. Journal of China University of Mining & Technology, 40(04), 544-548,555. in Chinese.
7. Feng, S., Yang, Y., Xue, Y., & Yu, Y. (2021). A post-tensioned hybrid beam-column connection with a web friction device: Experimental study and theoretical analysis. Journal of Building Engineering, 43, Article 103105. https://doi.org/10.1016/j.jobe.2021.10310510.1016/j.jobe.2021.103105 ↗
8. Feng, S., Yang, Y., Xue, Y., & Yu, Y. (2024). Numerical investigation on the hysteretic performance of self-centering precast steel-concrete hybrid frame. Buildings, 14(10), 3202. https://doi.org/10.3390/buildings1410320210.3390/buildings14103202 ↗
9. GB 50010-2010, Code for the design of concrete structures, China Architecture and Building Press, Beijing, 2010. (in Chinese).
10. Gu, A., Zhou, Y., Xiao, Y., Li, Q., & Qu, G. (2019). Experimental study and parameter analysis on the seismic performance of self-centering hybrid reinforced concrete shear walls. Soil Dynamics and Earthquake Engineering, 116, 409–420. https://doi.org/10.1016/j.soildyn.2018.10.00310.1016/j.soildyn.2018.10.003 ↗
11. Hao, J., Sun, X., Xue, Q., & Fan, C. (2017). Research and applications of prefabricated steel structure building systems. Engineering Mechanics, 34(1), 1–13. https://doi.org/10.6052/j.issn.1000-4750.2016.08.ST14. in Chinese.10.6052/j.issn.1000-4750.2016.08.ST14 ↗
12. He, L., & Wang, J. (2015). Method of equivalent load and temperature reduction on prestressing tendon for effective prestress simulation. Journal of Highway and Transportation Research and Development, 32(11), 75–80. in Chinese.
13. Hou, C., Ma, G., Hwang, H. J., Li, S., & Kang, S. M. (2024). Seismic retrofit of intact and damaged RC columns using prefabricated steel cage-reinforced UHPC jackets and NSM GFRP bars. Engineering Structures, 317, Article 118665. https://doi.org/10.1016/j.engstruct.2024.11866510.1016/j.engstruct.2024.118665 ↗
14. Hu, G., Huang, W., & Xie, H. (2020). Mechanical behavior of a replaceable energy dissipation device for precast concrete beam-column connections. Journal of Constructional Steel Research, 164, Article 105816. https://doi.org/10.1016/j.jcsr.2019.10581610.1016/j.jcsr.2019.105816 ↗
15. Hu, G., Zhang, Z., Cao, B., Pan, Z., & Zeng, L. (2024). Seismic behavior of precast concrete beam-column joints with bending moment-shear separation controllable plastic hinge. Engineering Structures, 304, Article 117585. https://doi.org/10.1016/j.engstruct.2024.11758510.1016/j.engstruct.2024.117585 ↗
16. Huang, W., Hu, G., Miao, X., & Fan, Z. (2021a). Seismic performance analysis of a novel demountable precast concrete beam-column connection with multi-slit devices. Journal of Building Engineering, 44, Article 102663. https://doi.org/10.1016/j.jobe.2021.10266310.1016/j.jobe.2021.102663 ↗
17. Huang, W., Hu, G., Miao, X., Liu, X., & Xie, H. (2021b). Seismic performance of concrete-filled steel tube devices for precast concrete beam-column connections. Journal of Mechanics of Materials and Structures, 16(1), 63–88. https://doi.org/10.2140/jomms.2021.16.6310.2140/jomms.2021.16.63 ↗
18. Huang, W., Hu, G., & Zhang, J. (2022). Experimental study on the seismic performance of new precast concrete beam-column joints with replaceable connection. Structures, 35, 856–872. https://doi.org/10.1016/j.istruc.2021.11.050.10.1016/j.istruc.2021.11.050. ↗
19. Huang, Y., Mazzarolo, E., Briseghella, B., Zordan, T., & Chen, A. (2017). Experimental and numerical investigation of the cyclic behaviour of an innovative prefabricated beam-to-column joint. Engineering Structures, 150, 373–389. https://doi.org/10.1016/j.engstruct.2017.07.05610.1016/j.engstruct.2017.07.056 ↗
20. Jiang, Z. Q., Chen, M. L., Yang, Z. S., Li, X. Y., & Cai, C. (2022). Cyclic loading tests of self-centering prestressed prefabricated steel beam-column joint with weakened FCP. Engineering Structures, 252, Article 113578. https://doi.org/10.1016/j.engstruct.2021.11357810.1016/j.engstruct.2021.113578 ↗
21. Kurama, Y. C., Sritharan, S., Fleischman, R. B., Restrepo, J. I., Henry, R. S., Cleland, N. M., & Bonelli, P. (2018). Seismic-resistant precast concrete structures: State of the art. Journal of Structural Engineering, 144(4), 03118001. https://doi.org/10.1061/(ASCE)ST.1943-541X.000197210.1061/(ASCE)ST.1943-541X.0001972 ↗
22. Li, F., Zhou, C., & Zheng, Z. (2016). Technical and economic analysis of monolithic precast concrete frame-cast-in-situ shear wall structure, Building. Structure, 46(10), 107–111. https://doi.org/10.19701/j.jzjg.2016.10.019. in Chinese.10.19701/j.jzjg.2016.10.019 ↗
23. Liu, J., Xu, L., & Xie, X. (2022). Seismic design and performance of a steel frame-shear plate shear wall with self-centering energy dissipation braces structure. Journal of Building Engineering, 51, Article 104336. https://doi.org/10.1016/j.jobe.2022.10433610.1016/j.jobe.2022.104336 ↗
24. Ma, G., Hou, C., Hwang, H. J., Chen, L., & Zhang, Z. (2024). Seismic behavior of repairable columns with UHPC segments and replaceable buckling-restrained energy dissipaters. Engineering Structures, 300, Article 117176. https://doi.org/10.1016/j.engstruct.2023.11717610.1016/j.engstruct.2023.117176 ↗
25. Ma, G., Qin, C. X., Hwang, H. J., & Zhou, Z. Z. (2023a). Data-driven models for predicting tensile load capacity and failure mode of grouted splice sleeve connection. Engineering Structures, 289, Article 116236. https://doi.org/10.1016/j.engstruct.2023.11623610.1016/j.engstruct.2023.116236 ↗
26. Ma, G., Zhang, Y., Hwang, H. J., & Kim, D. J. (2025). Mechanical properties of half grouted sleeve connections with insufficient grouting and bar eccentricity defects. Structures, 75, Article 108852. https://doi.org/10.1016/j.istruc.2025.108852.10.1016/j.istruc.2025.108852. ↗
27. Ma, L., Shi, Q., Wang, B., Tao, Y., & Wang, P. (2023b). Research on design and numerical simulation of self-centering prefabricated RC beam-column joint with pre-pressed disc spring devices. Soil Dynamics and Earthquake Engineering, 166, Article 107762. https://doi.org/10.1016/j.soildyn.2023.10776210.1016/j.soildyn.2023.107762 ↗
28. Nakashima, M., Suita, K., Morisako, K., & Maruoka, Y. (1998). Tests of welded beam-column subassemblies. I: Global behavior. Journal of Structural Engineering, 124(11), 1236–1244. https://doi.org/10.1061/(ASCE)0733-9445(1998)124:11(1236).10.1061/(ASCE)0733-9445(1998)124:11(1236). ↗
29. Park, R. (1988). Ductility evaluation from laboratory and analytical testing. In Proceedings of the 9th world conference on earthquake engineering (Vol. 8, pp. 605–616). Tokyo-Kyoto Japan.
30. Priestley, M. N. (1991). Overview of PRESSS research program. PCI Journal, 36(4), 50–57. https://doi.org/10.15554/pcij.07011991.50.57.10.15554/pcij.07011991.50.57. ↗
31. Qi, K., Wei, R., Chen, J., & Chen, J. (2019). Experimental studies on the quasi-static behavior of fabricated frame joints with new beam-end metallic dampers. Journal of Nanchang University(engineering & Technology), 41(04), 328–335. https://doi.org/10.3969/j.issn.1006-0456.2019.04.005. in Chinese.10.3969/j.issn.1006-0456.2019.04.005 ↗
32. Qi Yihe, Teng Jun, Shan Qingfei, Ding Jiapan, Li Zuohua, Huang Chenguang, & Yi Wenquan. (2021). Seismic performance of a novel prefabricated beam-to-column steel joint considering buckling behaviour of dampers. Engineering Structures, 229, Article 111591. https://doi.org/10.1016/j.engstruct.2020.11159110.1016/j.engstruct.2020.111591 ↗
33. Qian, H., Wang, X., Li, Z., & Zhang, Y. (2023). Experimental study on re-centering behavior and energy dissipation capacity of prefabricated concrete frame joints with shape memory alloy bars and engineered cementitious composites. Engineering Structures, 277, Article 115394. https://doi.org/10.1016/j.engstruct.2022.11539410.1016/j.engstruct.2022.115394 ↗
34. Shi, Q., Ma, L., Wang, Q., Wang, B., & Yang, K. (2021). Seismic performance of square concrete columns reinforced with grade 600 MPa longitudinal and transverse reinforcement steel under high axial load. Structures, 32, 1955–1970. https://doi.org/10.1016/j.istruc.2021.03.110.10.1016/j.istruc.2021.03.110. ↗
35. Sidoroff, F. (1981). Description of anisotropic damage application to elasticity. In Physical non-linearities in structural analysis: symposium senlis, France May 27–30, 1980 (pp. 237–244). Berlin, Heidelberg: Springer Berlin Heidelberg. https://doi.org/10.1007/978-3-642-81582-9_35.10.1007/978-3-642-81582-9_35 ↗
36. Song, L. L., Guo, T., & Chen, C. (2014). Experimental and numerical study of a self-centering prestressed concrete moment resisting frame connection with bolted web friction devices. Earthquake Engineering & Structural Dynamics, 43(4), 529–545. https://doi.org/10.1002/eqe.235810.1002/eqe.2358 ↗
37. Su, H., Yang, C., Fan, W., Sun, C., & Guo, W. (2025). Hysteresis characteristics of multi-segment precast columns with ultra-high performance concrete-based grouted sleeve connections: An experimental and analytical approach. Engineering Structures, 322, Article 119157. https://doi.org/10.1016/j.engstruct.2024.11915710.1016/j.engstruct.2024.119157 ↗
38. Su, H., Yang, C., Sun, C., Hu, L., & Fan, W. (2024). Seismic performance of precast multi-segment columns with grouted sleeves: Experimental and numerical investigations. Engineering Structures, 301, Article 117239. https://doi.org/10.1016/j.engstruct.2023.11723910.1016/j.engstruct.2023.117239 ↗
39. Vidjeapriya, R., & Jaya, K. P. (2013). Experimental study on two simple mechanical precast beam-column connections under reverse cyclic loading. Journal of Performance of Constructed Facilities, 27(4), 402–414. https://doi.org/10.1061/(ASCE)CF.1943-5509.000032410.1061/(ASCE)CF.1943-5509.0000324 ↗
40. Wang, H., Marino, E. M., Pan, P., Liu, H., & Nie, X. (2018). Experimental study of a novel precast prestressed reinforced concrete beam-to-column joint. Engineering Structures, 156, 68–81. https://doi.org/10.1016/j.engstruct.2017.11.01110.1016/j.engstruct.2017.11.011 ↗
41. Wang, W., Fang, C., & Liu, J. (2017). Self-centering beam-to-column connections with combined superelastic SMA bolts and steel angles. Journal of Structural Engineering, 143(2), 04016175. https://doi.org/10.1061/(ASCE)ST.1943-541X.000167510.1061/(ASCE)ST.1943-541X.0001675 ↗
42. Wang, X. T., Xie, C. D., Lin, L. H., & Li, J. (2019). Seismic behavior of self-centering concrete-filled square steel tubular (CFST) column base. Journal of Constructional Steel Research, 156, 75–85. https://doi.org/10.1016/j.jcsr.2019.01.02510.1016/j.jcsr.2019.01.025 ↗
43. Wei, S. (2024). Experimental and theoretical study of seismic performance of new recoverable beam-column joints. Hunan University.
44. Wu, C., Ma, G., Zhu, D., Qu, H., & Zhuang, H. (2024). Seismic retrofitting of GFRP-reinforced concrete columns using precast UHPC plates. Soil Dynamics and Earthquake Engineering, 187, Article 109024. https://doi.org/10.1016/j.soildyn.2024.10902410.1016/j.soildyn.2024.109024 ↗
45. Yang, Y., Feng, S., Xue, Y., & Yu, Y. (2021). Experimental investigation on the seismic behaviour of innovative self-centring precast steel-concrete hybrid frames. Engineering Structures, 239, 112222. https://doi.org/10.1016/j.engstruct.2021.11222210.1016/j.engstruct.2021.112222 ↗
46. Yu, J., Zhang, W., Tang, Z., Guo, X., & Pospíšil, S. (2020). Seismic behavior of precast concrete beam-column joints with steel strand inserts under cyclic loading. Engineering Structures, 216, Article 110766. https://doi.org/10.1016/j.engstruct.2020.11076610.1016/j.engstruct.2020.110766 ↗
47. Zhang, H., Huang, W., Liu, B., Li, S., Li, Q., & Mao, L. (2024). Numerical analysis of a prefabricated concrete beam-to-column connection with bolted end plates. Structures, 59, Article 105778. https://doi.org/10.1016/j.istruc.2023.10577810.1016/j.istruc.2023.105778 ↗
48. Zhang, J., Cai, R., Li, C., & Liu, X. (2020). Seismic behavior of high-strength concrete columns reinforced with high-strength steel bars. Engineering Structures, 218, Article 110861. https://doi.org/10.1016/j.engstruct.2020.11086110.1016/j.engstruct.2020.110861 ↗
49. Zhang, P., Lu, Z., & Dan, H. (2010). The survey analysis of prefabricated structure in Wenchuan earthquake. Sichuan Building Science, 36, 129–133. in Chinese.
50. Zhang, R., Zhang, Y., Li, A., & Yang, T. Y. (2022). Experimental study on a new type of precast beam-column joint. Journal of Building Engineering, 51, Article 104252. https://doi.org/10.1016/j.jobe.2022.10425210.1016/j.jobe.2022.104252 ↗
51. Zhao, B., Taucer, F., & Rossetto, T. (2009). Field investigation on the performance of building structures during the 12 May 2008 Wenchuan earthquake in China. Engineering Structures, 31(8), 1707–1723. https://doi.org/10.1016/j.engstruct.2009.02.03910.1016/j.engstruct.2009.02.039 ↗