The Behavior of Post-installed Rebar Connectors in Steel Frame Retrofitted Concrete Structures Under Combined Shear and Tension
Source abstract
Abstract
Abstract To investigate the response of post-installed rebar connectors in steel frame retrofitted concrete structures under combined shear and tension, seven shear-and-tensile tests were conducted. The bearing capacity, stiffness, and hysteresis behavior of the connectors were investigated during the tests. Both Monotonic and cyclic load regimes were applied in the loading process. The results show that with the increase of the loading angle, the deformation capacity, the yield force, ultimate tensile force, and tensile stiffness of the specimen decrease, while the maximum shear force and shear stiffness of the specimen increase. The bearing capacity, stiffness, and energy dissipation performance of the specimen under a monotonic load is greater than that under the coupled shear-and-pull load. The bearing capacity, stiffness, hysteresis curve, and failure status of the specimens are not affected by different loading regimes. At the end, the design formula of anchor bolt for this type of connectors from the design code of China, United States, and Japan were compared. Formulas to calculate the shear strength under combined shear and tension is developed.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Response to Dynamic Loads · Concrete Corrosion and Durability
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (28)
Show source-provided references
1. ACI318—11 Building Code Requirements for Structural Concrete and Commentary. American Concrete Institute, 2013.
2. AISC360—16, Specifications for Structural Steel Buildings[S]. American Institute of Steel Construction, 2016.
3. Çalışkan, Ö., Yılmaz, S., Kaplan, H., & Kıraç, N. (2013). Shear strength of epoxy anchors embedded into low strength concrete. Construction and Building Materials, 38(2), 723–730.10.1016/j.conbuildmat.2012.09.020 ↗
4. Cheng, L., Jiansheng, F., & Jianguo, N. (2017). Fatigue performance research of headed studs in steel and ultra-high performance concrete composite deck. China Journal of Highway and Transport, 30(3), 139–146.
5. Civil and Structural Groups of Tsinghua University, Xian Jiaotong University and Beijing Jiaotong University. (2008). Analysis on seismic damage of buildings in the Wenchuan earthquake. Journal of Building Structures, 29(4), 1–9.
6. Design Recommendations for Composite Constructions. Architectural Institute of Japan, 2010.
7. Ding, H., Guo, Y., Liang, Y., & Zhang, P. (2016). Experimental research on seismic performance of storey-adding frame structures. Transactions of Tianjin University, 22(1), 43–49.10.1007/s12209-016-2465-9 ↗
8. Fu, F., & Parke, G. A. R. (2018). Assessment of the progressive collapse resistance of double-layer grid space structures using implicit and explicit methods. International Journal of Steel Structures, 18(3), 831–842.10.1007/s13296-018-0030-1 ↗
9. Gao, S., Guo, L., Fu, F., & Zhang, S. (2017). Capacity of semi-rigid composite joints in accommodating column loss. Journal of Constructional Steel Research, 139, 288–301.10.1016/j.jcsr.2017.09.029 ↗
10. Gesoğlu, M., Güneyisi, E. M., Güneyisi, E., Yılmaz, M. E., & Mermerdaş, K. (2014). Modelling and analysis of the shear capacity of adhesive anchors post-installed into uncracked concrete. Composites, Part b: Engineering, 60(1), 716–724.10.1016/j.compositesb.2014.01.015 ↗
11. Jianguo, N., Yixin, Li., & Muxuan, T. (2014). Slip performance and hysteresis model of a new type of uplift restricted-slip free connectors. Engineering Mechanics, 31(11), 46–52.
12. Lee, J., Goldsworthy, H. M., & Gad, E. F. (2010). Blind bolted T-stub connections to unfilled hollow section columns in low rise structures. Journal of Constructional Steel Research, 66(8/9), 981–992.10.1016/j.jcsr.2010.03.016 ↗
13. Liu, C., Yu, J., Lu, Z., & Wang, K. (2010). Experimental study on bond-slip behavior of post-installed rebar at high temperature. Journal of Tongji University, 38(11), 1579–1585.
14. Ministry of Housing and Urban-Rural Development, People’s Republic of China. JGJ145—2004 Technical specification for post-installed fastenings in concrete structures. China Architecture & Building Press, 2005.
15. Ministry of Housing and Urban-Rural Development, People’s Republic of China. GB50011—2010 Code for seismic design of building. China Architecture & Building Press, 2010.
16. Ministry of Housing and Urban-Rural Development, People’s Republic of China. JGJ145—2013 Technical specification for post-installed fastenings in concrete structures. China Architecture & Building Press, 2013.
17. Mourad, S. (1993). Behaviour of blind bolted moment connections for square HSS columns. Memaster University.
18. Mourad, S., Korol, R. M., & Ghobarah, A. (1996). Design of extended endplata connections for hollow section columns. Canadian Journal of Civil Engineering, 23(1), 277–286.10.1139/l96-029 ↗
19. Nie, J. G., Li, Y. X., Tao, M. X., & Nie, X. (2015). New technique and application of uplift-restricted and slip-permitted connection. China Civil Engineering Journal, 48(4), 7–14.
20. Peng, H., Liu, D. W., Dai, B., Zeng, S. S., & Chu, F. J. (2018). Experimental research on load-shear performance of interface between new and old concrete with corroded post-installed bar. Chinese Journal of Engineering, 40(1), 23–30.
21. Qian, K., Geng, S. Y., Liang, S. L., Fu, F., & Yu, J. (2022). Effects of loading regimes on the structural behavior of RC beam-column sub-assemblages against disproportionate collapse. Engineering Structures, 251, 113470.10.1016/j.engstruct.2021.113470 ↗
22. Qian, K., Liang, S. L., Feng, D. C., Fu, F., & Wu, G. (2020). Experimental and numerical investigation on progressive collapse resistance of post-tensioned precast concrete beam-column sub-assemblages. Journal of Structural Engineering, 146(9), 04020170.10.1061/(ASCE)ST.1943-541X.0002714 ↗
23. Qian, K., Weng, Y. H., Fu, F., & Deng, X. F. (2021). Numerical evaluation of the reliability of using single-story substructures to study progressive collapse behaviour of multi-story RC frames. Journal of Building Engineering, 33, 101636.10.1016/j.jobe.2020.101636 ↗
24. Wang, L., Shen, N., Zhang, M., Fu, F., & Qian, K. (2020). Bond performance of Steel-CFRP bar reinforced coral concrete beams. Construction and Building Materials, 245, 118456.10.1016/j.conbuildmat.2020.118456 ↗
25. Xiaosong, R., Xianyu, W., Bin, Z. (2018). Experimental study on seismic behavior of post-installed reinforced concrete-masonry composite wall connected with embedded bars. Journal of Building Structures, 39(4), 45–53.
26. Xie, G. H., Liu, R. G., Chen, B., Li, M. J., & Shi, T. G. (2015). Synergistic effect of a new wedge-bond-type anchor for CFRP tendons. Journal of Central South University, 22(6), 2260–2266.10.1007/s11771-015-2750-0 ↗
27. Yilmaz, S., Özen, M. A., & Yardim, Y. (2013). Tensile behavior of post-installed chemical anchors embedded to low strength concrete. Construction and Building Materials, 47(5), 861–866.10.1016/j.conbuildmat.2013.05.032 ↗
28. Zhang, Y., Lou, G., Li, G., et al. (2016). Experimental study of bond strength of anchorage adhesive after heating. Journal of Tongji University, 44(11), 1723–1728.