journal article·2024-02-13Open access

Steel Fiber Orientation Efficiency Factor Model for a Magnetically Treated Cement-Based Composite

Nur Indah Mukharromah, Do Young Moon

Abstract

Abstract In typical steel fiber-reinforced concrete, the fibers are randomly distributed and oriented throughout the matrix, and a magnetic field can effectively align these randomly oriented fibers. To predict the extent to which the steel fibers contained in mortar can be aligned by a magnetic field, an analytical steel fiber orientation efficiency factor model was proposed as a function of the magnetic induction intensity and exposure time. To verify the applicability of the proposed model, experiments were conducted for various magnetic induction intensities and exposure times with normal mortars and mortars in which some or all the sand was replaced with steel slag. The experimental results demonstrate that the proposed model allows predicting the degree of alignment of steel fibers under magnetic fields. However, this model can only be applied to a normal mortar. In the case of mortar containing steel slag, it is confirmed that the steel slag, which is a ferrous material, reduces the magnetic induction intensity, reducing the degree of alignment of steel fibers in the mortar.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Innovative concrete reinforcement materials · Graphite, nuclear technology, radiation studies · Smart Materials for Construction

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (28)

Show source-provided references
1. Alavizadeh-Farhang, A., & Silfwerbrand, J. (2000). Responses of plain and steel fiber-reinforced concrete beams to temperature and mechanical loads: Experimental study. Transportation Research Record, 1740(1), 25–32.10.3141/1740-04 ↗
2. Ashare, E., Bird, R. B., & Lescarboura, J. A. (1965). Falling cylinder viscometer for non-Newtonian fluids. AIChE Journal, 11(5), 910–916.10.1002/aic.690110530 ↗
3. Baun, M. D. (1993). Steel fiber-reinforced concrete bridge deck overlays: Experimental use by ohio department of transportation. Transportation Research Record, 1392, 73–78.
4. Chen, M. C. S., Lescarboura, J. A., & Swift, G. W. (1968). The effect of eccentricity on the terminal velocity of the cylinder in a falling cylinder viscometer. AIChE Journal, 14(1), 123–127.10.1002/aic.690140122 ↗
5. Dupont, D., & Vandewalle, L. (2005). Distribution of steel fibres in rectangular sections. Cement and Concrete Composites, 27(3), 391–398.10.1016/j.cemconcomp.2004.03.005 ↗
6. Eichstadt, F. J., & Swift, G. W. (1966). Theoretical analysis of the falling cylinder viscometer for power law and bingham plastic fluids. AIChE Journal, 12(6), 1179–1183.10.1002/aic.690120624 ↗
7. Ghailan, D. B., & Al-Ghalib, A. A. (1971). Magnetic alignment of steel Fibres in self-compacting concrete. Australian Journal of Structural Engineering, 20(4), 333–341.
8. Hrynyk, T. D., & Vecchio, F. J. (2014). Behavior of steel fiber-reinforced concrete slabs under impact load. Structural Journal, 111(5), 1213–1224.10.14359/51686923 ↗
9. Huang, H., Gao, X., & Khayat, K. H. (2021). Contribution of fiber alignment on flexural properties of UHPC and prediction using the composite theory. Cement and Concrete Composites, 118, 103971.10.1016/j.cemconcomp.2021.103971 ↗
10. Kazemi, M. T., Fazileh, F., & Ebrahiminezhad, M. A. (2007). Cohesive crack model and fracture energy of steel-fiber-reinforced-concrete notched cylindrical specimens. Journal of Materials in Civil Engineering, 19(10), 884–890.10.1061/(ASCE)0899-1561(2007)19:10(884) ↗
11. Khan, S., Qing, L., Ahmad, I., Mu, R., & Bi, M. (2022). Investigation on fracture behavior of cementitious composites reinforced with aligned hooked-end steel fibers. Materials, 15(2), 542.10.3390/ma15020542 ↗
12. Kim, J., Lee, G. P., & Moon, D. Y. (2015). Evaluation of mechanical properties of steel-fibre-reinforced concrete exposed to high temperatures by double-punch test. Construction and Building Materials, 79, 182–191.10.1016/j.conbuildmat.2015.01.042 ↗
13. Laws, V. (1971). The efficiency of fibrous reinforcement of brittle matrices. Journal of Physics D: Applied Physics, 4(11), 1737.10.1088/0022-3727/4/11/318 ↗
14. Lee, S. C., Oh, J. H., & Cho, J. Y. (2014). Fiber orientation factor on a circular cross-section in concrete members. Journal of the Korea Concrete Institute, 26(3), 307–313.10.4334/JKCI.2014.26.3.307 ↗
15. Lohrenz, J., Swift, G. W., & Kurata, F. (1960). An experimentally verified theoretical study of the falling cylinder viscometer. AIChE Journal, 6(4), 547–550.10.1002/aic.690060408 ↗
16. Madandoust, R., Kazemi, M., Talebi, P. K., & de Brito, J. (2019). Effect of the curing type on the mechanical properties of lightweight concrete with polypropylene and steel fibres. Construction and Building Materials, 223, 1038–1052.10.1016/j.conbuildmat.2019.08.006 ↗
17. Michels, J., & Gams, M. (2016). Preliminary study on the influence of fibre orientation in fibre reinforced mortars. Gradevinar, 68(8), 645–655.
18. Miller, A. I., & Bjorklund, F. R. (1977). U.S. Patent No. 4,062,913. Washington, DC: U.S. Patent and Trademark Office.
19. Moon, J. S., & Kang, S. T. (2018). Prediction of tensile behavior of UHSFRC considering the flow field in the placing dominated by shear flow. Materials, 11(2), 194.10.3390/ma11020194 ↗
20. Mu, R., Li, H., Qing, L., Lin, J., & Zhao, Q. (2017). Aligning steel fibers in cement mortar using electro-magnetic field. Construction and Building Materials, 131, 309–316.10.1016/j.conbuildmat.2016.11.081 ↗
21. Mu, R., Qiu, X., Zhao, Q., & Li, H. (2015). Aligned steel fibre reinforced cement based composites(I): Orientation control of steel fibres. Journal of Building Materials, 18(2), 208–213.
22. Mu, R., Wei, L., Wang, X., Li, H., Qing, L., Zhou, J., & Zhao, Q. (2018). Preparation of aligned steel fiber reinforced cementitious composite and its flexural behavior. Journal of Visualized Experiments, 136, e56307.
23. Namli, M. (2021). Evaluation of the effect of using fiber reinforcement in tunnel linings for metro projects. Underground Space, 6(6), 732–750.10.1016/j.undsp.2021.08.002 ↗
24. Sebaibi, N., Benzerzour, M., & Abriak, N. E. (2014). Influence of the distribution and orientation of fibres in a reinforced concrete with waste fibres and powders. Construction and Building Materials, 65, 254–263.10.1016/j.conbuildmat.2014.04.134 ↗
25. Song, Q., Yu, R., Shui, Z., Wang, X., Rao, S., Lin, Z., & Wang, Z. (2018). Key parameters in optimizing fibres orientation and distribution for Ultra-High Performance Fibre Reinforced Concrete (UHPFRC). Construction and Building Materials, 188, 17–27.10.1016/j.conbuildmat.2018.08.102 ↗
26. Soroushian, P., & Lee, C. D. (1990). Distribution and orientation of fibers in steel fiber reinforced concrete. Materials Journal, 87(5), 433–439.
27. Svedberg, B. (2004). U.S. Patent No. 6,740,282. Washington, DC: U.S. Patent and Trademark Office.
28. Valdez Aguilar, J., Juárez-Alvarado, C. A., Mendoza-Rangel, J. M., & Terán-Torres, B. T. (2021). Effect of the notch-to-depth ratio on the post-cracking behavior of steel-fiber-reinforced concrete. Materials, 14(2), 445.10.3390/ma14020445 ↗