journal article·2020-12Open access

Analysis of Interface Properties Between TRC and Concrete Under Chloride Attack Based on Fracture Energy

Shichang Li, Shiping Yin, Yu Gao

Abstract

Abstract As a type of cement-based composite reinforcement material, textile reinforced concrete (TRC) has the advantages of corrosion resistance, high bearing capacity and good crack limit performance. Its bonding performance with the existing concrete interface is the key factor affecting the reinforcement effect. To study the interfacial adhesion between TRC and existing concrete, the sodium chloride concentration, the frequency and number of dry and wet cycles, the bonding length of the TRC reinforcement layer and the type of reinforcement were analysed by a double-sided shear test, XRD (X-ray diffraction) and SEM (scanning electron microscope) micro-test techniques. The influence of other factors on the interfacial bonding properties was further elaborated based on the theory of fracture energy. The results show that interface damage under chloride attack was mainly divided into three typical interface failure modes. By increasing the concentration of sodium chloride, reducing the frequency of dry and wet cycles and increasing the number of dry and wet cycles, the interface microstructure damage could be aggravated. Using cast-in-place reinforcement and increasing the bonding length could enhance the bonding performance of the interface.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Masonry and Concrete Structural Analysis · Building materials and conservation · Innovative concrete reinforcement materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (23)

Show source-provided references
1. Ascione, L., Felice, G., & Santis, S. (2015). A qualification method for externally bonded Fibre Reinforced Cementitious Matrix (FRCM) strengthening systems. Composites Part B Engineering,78, 497–506.10.1016/j.compositesb.2015.03.079 ↗
2. Balonis, M., Lothenbach, B., Saout, G. L., & Glasser, F. P. (2010). Impact of chloride on the mineralogy of hydrated Portland cement systems. Cement and Concrete Research,40(7), 1009–1022.10.1016/j.cemconres.2010.03.002 ↗
3. Barhum, R., & Mechtcherine, V. (2012). Effect of short, dispersed glass and carbon fibres on the behaviour of textile-reinforced concrete under tensile loading. Engineering Fracture Mechanics,92(92), 56–71.10.1016/j.engfracmech.2012.06.001 ↗
4. Bournas, D. A., Lontou, P. V., Papanicolaou, C. G., & Triantafillou, T. C. (2007). Textile-reinforced mortar versus fiber-reinforced polymer confinement in reinforced concrete columns. ACI Structural Journal,104(6), 740–748.
5. D’Ambrisi, A., Feo, L., & Focacci, F. (2012). Bond-slip relations for PBO-FRCM materials externally bonded to concrete. Composites: Part B,43(8), 2938–2949.10.1016/j.compositesb.2012.06.002 ↗
6. D’Ambrisi, A., Feo, L., & Focacci, F. (2013). Experimental analysis on bond between PBO-FRCM strengthening materials and concrete. Composites: Part B,44, 524–532.10.1016/j.compositesb.2012.03.011 ↗
7. Detassis, M., Frydman, E., Vrieling, D., Zhou, X. F., Wagner, H. D., & Nairn, J. A. (1996). Interface toughness in fibre composites by the fragmentation test. Composites: Part A,27(9), 769–773.10.1016/1359-835X(96)00045-0 ↗
8. Diab, A. M., Elmoaty, A. E. M. A., & Eldin, M. R. T. (2017). Slant shear bond strength between self compacting concrete and old concrete. Construction and Building Materials,130, 73–82.10.1016/j.conbuildmat.2016.11.023 ↗
9. Elakneswaran, Y., Nawa, T., & Kurumisawa, K. (2009). Electrokinetic potential of hydrated cement in relation to adsorption of chlorides. Cement and Concrete Research,39(4), 340–344.10.1016/j.cemconres.2009.01.006 ↗
10. Hegger, J., Will, N., Bruckermann, O., & Voss, S. (2006). Loading-bearing behavior and simulation of textile-reinforced concrete. Materials and Structures,39(8), 765–776.10.1617/s11527-005-9039-y ↗
11. Li, G., Xie, H., & Xiong, G. (2001). Transition zone studies of new-to-old concrete with different binders. Cement & Concrete Composites,23(4–5), 381–387.10.1016/S0958-9465(01)00002-6 ↗
12. Lu, C., Gao, Y., Cui, Z., & Liu, R. (2007). Experimental analysis of chloride penetration into concrete subjected to drying-wetting cycles. Journal of Materials in Civil Engineering,27(12), 77–86.
13. Marinescu, M., & Brouwers, J. (2012). Chloride binding related to hydration products part I: ordinary Portland Cement. Cement and Concrete Research,42(2), 282–290.10.1016/j.cemconres.2011.09.016 ↗
14. Momayez, A., Ehsani, M., Ramezanianpour, A., & Rajaie, H. (2005). Comparison of methods for evaluating bond strength between concrete substrate and repair materials. Cement and Concrete Research,35(4), 748–757.10.1016/j.cemconres.2004.05.027 ↗
15. Mousa, M. (2015). Factors affecting bond between repairing concrete and concrete substrate. International Journal of Engineering and Innovative Technology,4(11), 47–56.
16. Ortlepp, R., Hampel, U., & Curbach, M. (2006). A new approach for evaluating bond capacity of TRC strengthening. Cement & Concrete Composites,28, 589–597.10.1016/j.cemconcomp.2006.05.003 ↗
17. Peled, A. (2007). Confinement of damaged and non-damaged structural concrete with FRP and TRC sleeves. Journal of Composites for Construction,11(5), 514–522.10.1061/(ASCE)1090-0268(2007)11:5(514) ↗
18. Triantafillou, T. C., Papanicolaou, C. G., Zissimopoulos, P., & Laourdekis, T. (2006). Concrete confinement with textile-reinforced mortar jackets. ACI Structural Journal,103(1), 28–37.
19. Yang, S., Chen, Y., Du, D., & Fan, G. (2016). Determination of boundary effect on shear fracture energy at steel bar-concrete interface. Engineering Fracture Mechanics,153, 319–330.10.1016/j.engfracmech.2015.12.031 ↗
20. Yin, S. P., Li, Y., Jin, Z. Y., & Li, P. H. (2018a). Interfacial properties of textile-reinforced concrete and concrete in the chloride freeze–thaw cycle. ACI Materials Journal,115(2), 197–208.10.14359/51701919 ↗
21. Yin, S. P., Xu, S., & Lv, H. (2014). Flexural behavior of reinforced concrete beams with TRC tension zone cover. Journal of Materials in Civil Engineering,26(2), 320–330.10.1061/(ASCE)MT.1943-5533.0000811 ↗
22. Yin, S. P., Xu, S., & Wang, F. (2015). Investigation on the flexural behavior of concrete members reinforced with epoxy resin-impregnated textiles. Materials and Structures,48(1–2), 153–166.10.1617/s11527-013-0174-6 ↗
23. Yin, S. P., Zhao, L., & Li, P. H. (2018b). Failure model of bond force between TRC and old concrete. Journal of Hunan University (Natural Sciences),45(01), 77–83. (in Chinese).