journal article·2025-04-09Open access

Hybrid Reinforced Concrete Cross-Section Using Fiber-Reinforced Polymer and Steel Bars

Zahid Hussain, Federico Tuozzo, Gennaro Magliulo, Antonio Nanni

Abstract

Abstract Fiber-reinforced polymer (FRP) bars offer a promising alternative to conventional steel reinforcement in reinforced concrete (RC) structures, primarily due to their corrosion resistance. However, their intrinsic linear elastic behavior may limit their applications to non-seismic zones or regions with limited seismic activity. To extend their applications in seismic zones such as Seismic Design Category D, a novel approach involving a hybrid-RC (HRC) cross-section is proposed. This approach entails placing FRP bars on the cross-section exterior for corrosion resistance, while steel bars on the inner side of the cross-section to ensure ductility and energy dissipation. This paper presents a methodology for designing HRC cross-sections and evaluates their ductility and energy dissipation capabilities. The discussion encompasses various design aspects of an HRC section including strength reduction factor, minimum reinforcement ratio, reinforcement strain, concrete shear strength, and the impact of confinement on ductility and energy dissipation. Additionally, an illustrative example of a HRC section demonstrates the practicality of the proposed design methodology in practical applications.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Innovative concrete reinforcement materials · Structural Load-Bearing Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (23)

Show source-provided references
1. ACI 440.1R-15. (2015). Guide for the Design and Construction of Structural Concrete Reinforced with Fiber-Reinforced Polymer (FRP) Bars. Farmington Hills, MI. ISBN: 978-1-942727-10-1. Retrieved from https://www.concrete.org/Portals/0/Files/PDF/Previews//440_1R_15.pdf.
2. ACI Committee 318-19. (2019). Building Code Requirements for Structural Concrete (ACI 318-19) and Commentary (ACI 318R-19). Farmington Hills MI. https://doi.org/10.14359/5171693710.14359/51716937 ↗
3. ACI Committee 440. (2022). Building code requirements for structural concrete reinforced with glass fiber-reinforced polymer (GFRP) bars: code and commentary (Vol. 1). Retrieved from https://www.concrete.org/Portals/0/Files/PDF/Previews//440.11-22_Preview.pdf.
4. Antonio, N., Antonio, D. L., & Hany Jawaheri, Z. (2014). FRP Reinforced Concrete Structures – Theory, Design and Practice (1st ed.). CRC Press. https://doi.org/10.1201/b1666910.1201/b16669 ↗
5. ASCE 7-16. (2016). Minimum Design Loads and Associated Criteria for Buildings and other Structures. https://doi.org/10.1061/978078441424810.1061/9780784414248 ↗
6. ASCE (41–17). (2017). Seismic evaluation and retrofit of existing buildings. 9780784414859
7. ASTM D7957/D7957M-22. (2022). Standard Specifications for Solid Round Glass Fiber Reinforced Polymer Bars for Concrete Reinforcement. West Conshocken, OA. https://doi.org/10.1520/D7957_D7957M-2210.1520/D7957_D7957M-22 ↗
8. ASTM D8505. (2023). Standard specification for basalt and glass fiber reinforced polymer (FRP) bars for concrete reinforcement. Farmington Hills, MI. https://doi.org/10.1520/D8505_D8505M-2310.1520/D8505_D8505M-23 ↗
9. Benmokrane, B., & Masmoudi, R. (1995). Flexural response of concrete beams reinforced with FRP reinforcing bars. ACI Structural Journal. https://doi.org/10.14359/983910.14359/9839 ↗
10. Chen, W., Pham, T. M., Sichembe, H., Chen, L., & Hao, H. (2018). Experimental study of flexural behaviur of RC beams strengthened by longitudinal and U-shaped basalt FRP sheet. Composites Part b: Engineering, 134, 114–126. https://doi.org/10.1016/j.compositesb.2017.09.05310.1016/j.compositesb.2017.09.053 ↗
11. Comité Européem de Normalisation. (2004). Eurocode 8: Design of Structures for Earthquake Resistance (in Italian). https://doi.org/10.1680/cien.2001.144.6.5510.1680/cien.2001.144.6.55 ↗
12. Deng, Z., Gao, L., & Wang, X. (2018). Glass fiber-reinforced polymer-reinforced rectangular concrete columns under simulated seismic loads. Journal of the Brazilian Society of Mechanical Sciences and Engineering, 40, 1–12. https://doi.org/10.1007/S40430-018-1041-810.1007/S40430-018-1041-8 ↗
13. Dong, H.-L., Wang, D., Wang, Z., & Sun, Y. (2018). Axial compressive behavior of square concrete columns reinforced with innovative closed-type winding GFRP stirrups. Composite Structures, 192, 115–125. https://doi.org/10.1016/j.compstruct.2018.02.09210.1016/j.compstruct.2018.02.092 ↗
14. Etman, E. E., Mahmoud, M. H., Hassan, A., & Mowafy, M. H. (2023). Flexural behaviour of concrete beams reinforced with steel-FRP composite bars. Structures, 50, 1147–1163. https://doi.org/10.1016/j.istruc.2023.02.09810.1016/j.istruc.2023.02.098 ↗
15. FEMA 273/1997. (1997). NEHRP Guidelines for the Seismic Rehabilitation of Buildings. Washington. https://courses.washington.edu/cee518/fema273.pdf.
16. Japan Society of Civil Engineers. (1997). Recommendation for Design and Construction of Concrete Structures Using Continuous Fiber Reinforcing Materials. Tokyo. https://www.jsce.or.jp/committee/concrete/e/web/pdf/31-1.pdf.
17. Joint ACI-ASCE Committee 445. (1998). Recent approaches to shear design of structural concrete. Journal of Structural Engineering, 1375–1417.10.1061/(ASCE)0733-9445(1998)124:12(1375) ↗
18. Liborio, C., Fabio Di, T., Marco Filippo, F., & Luigi, D. (2017). Stress-strain models for normal and high strength confined concrete: test and comparison of literature models reliability in reproducing experimental results. International Journal of Earthquake Engineering. https://iris.polito.it/handle/11583/2687411
19. NTC 2018. (2018). Norme Tecniche per le Costruzioni (in Italian). Retrieved from https://biblus.acca.it/download/norme-tecniche-per-lec-costruzioni-2018-ntc-2018--pdf/
20. Park, T.-S.E., & Hong-Gun. (2013). Evaluation of shear deformation and energy dissipation of reinforced concrete members subjected to cyclic loading. ACI Structural Journal, 110(5), 845–854. https://doi.org/10.14359/5168583710.14359/51685837 ↗
21. Prajapati, G. N., Farghaly, A. S., & Benmokrane, B. (2023). Behavior of glass fiber-reinforced polymer-reinforced concrete columns subjected to simulated seismic load. ACI Structural Journal, 120(1), 3–16. https://doi.org/10.14359/5173722810.14359/51737228 ↗
22. Tavassoli, A., Liu, J., & Sheikh, S. (2015). Glass fiber-reinforced polymer-reinforced circular columns under simulated seismic loads. ACI Structural Journal. https://doi.org/10.14359/5168722710.14359/51687227 ↗
23. Tureyen, A. K., & Frosh, J. R. (2003). Concrete shear strength; another perspective. ACI Structural Journal, 100(5), 609–615. https://doi.org/10.14359/1280210.14359/12802 ↗