Experimental and Theoretical Study of Concrete-Filled Steel Tube Columns Strengthened by FRP/Steel Strips Under Axial Compression

Shichang Zhang, Kunting Miao, Yang Wei, Xiaoming Xu, Bin Luo, Weizhou Shi

Abstract

Abstract Concrete-filled steel tube (CFST) columns are widely used in civil engineering because of their excellent bearing capacity; however, the reinforcement of CFST columns lacks effective measures. To strengthen CFST columns quickly and effectively, two methods, namely, winding FRP (fiber reinforced polymer) or steel strips, were explored in this work. Two unconfined CFST columns, eight FRP-strengthened CFST columns and four welded steel strip-strengthened CFST columns were manufactured and tested. The failure modes and axial load–strain curves of all specimens under compression load were concluded and compared. The effects of the primary parameters, such as FRP layers (1, 2, 3 and 4 layers) and steel strip thickness (3.0 and 6.0 mm), on the bearing capacity and deformation capacity were also investigated. The ultimate load of CFST columns increased from 28.72 to 64.16% after being confined by FRP with one to four layers. The ultimate load of the welded steel strip-strengthened CFST column with 3.0 mm steel strips and 6.0 mm steel strips increased by 28.46% and 49.82%, respectively, compared with the unconfined CFST column. Thus, the increase in FRP layers and steel strip thickness can markedly improve the compressive behavior of the FRP/welded steel strip-strengthened CFST columns. The cost performance of the two different reinforcement methods also showed that the cost of the welded steel strip-strengthened CFST column is nearly 40% of that of the FRP-strengthened CFST column when the same strengthening effect was obtained, which indicated that the welded steel strip-strengthened CFST column is more cost-efficient than CFST columns confined by FRP. Finally, six existing models for the ultimate load of FRP-strengthened CFST columns were presented and evaluated. From the evaluation results, the Zhang et al.’s model, Lu et al.’s model and Hu et al.’s model for FRP-strengthened CFST columns were shown to provide the best applicability and accuracy. Based on the Mander et al.’s model, a model for the ultimate load of welded steel strip-strengthened CFST columns was proposed and evaluated. The proposed model can accurately predict the ultimate load of welded steel strip-strengthened CFST columns.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Load-Bearing Analysis · Structural Engineering and Vibration Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (48)

Show source-provided references
1. Bradley, E. T., & Roberts, G. (2010). Crossing the Severn estuary, UK: challenges past and present. Proceedings of the Institution of Civil Engineers Engineering History & Heritage, 164, 123.10.1680/ehah.11.00002 ↗
2. Chin, C. L., Ma, C. K., Tan, J. Y., Ong, C. B., Awang, A. Z., & Omar, W. (2019). Review on development of external steel-confined concrete. Construction and Building Materials, 211, 919–931.10.1016/j.conbuildmat.2019.03.295 ↗
3. China SP. (2010). Metallic materials tensile testing at ambient temperature vol GB/T 228.1–2010. Beijing
4. China SPo. (2014). Test method for tensile properties of orientation fiber reinforced polymer matrix composite materials vol GB/T 3354—2014 Beijing
5. Choi, K. K., & Yan, X. (2010). Analytical model of circular CFRP confined concrete-filled steel tubular columns under axial compression. Journal of Composites for Construction, 14, 125–133.10.1061/(ASCE)CC.1943-5614.0000056 ↗
6. Ding, F. X., Liu, Y. C., Fei, Y., Lu, D. R., & Chen, J. (2020). Cyclic loading tests of stirrup cage confined concrete-filled steel tube columns under high axial pressure. Engineering Structures, 221, 111048.10.1016/j.engstruct.2020.111048 ↗
7. Ding, F. X., Lu, D. R., Bai, Y., Gong, Y. Z., Yu, Z. W., Ni, M., & Li, W. (2018). Behaviour of CFRP-confined concrete-filled circular steel tube stub columns under axial loading. Thin-Walled Structures, 125, 107–118.10.1016/j.tws.2018.01.015 ↗
8. Ekmekyapar, T., & Alhatmey, I. A. H. (2019). Post-fire resistance of internally ring stiffened high performance concrete filled steel tube columns. Engineering Structures, 183, 375–388.10.1016/j.engstruct.2019.01.024 ↗
9. Feng, P., Cheng, S., Ba, I. Y., & Ye, L. (2015). Mechanical behavior of concrete-filled square steel tube with FRP-confined concrete core subjected to axial compression. Composite Structures, 123, 312–324.10.1016/j.compstruct.2014.12.053 ↗
10. Han, L. H., Hou, C., & Wang, Q. L. (2012). Square concrete filled steel tubular (CFST) members under loading and chloride corrosion. Experiments Steel Construction, 71, 11–25.10.1016/j.jcsr.2011.11.012 ↗
11. Han, L. H., & Yao, G. H. (2004). Experimental behaviour of thin-walled hollow structural steel (HSS) columns filled with self-consolidating concrete (SCC). Thin-Walled Structures, 42, 1357–1377.10.1016/j.tws.2004.03.016 ↗
12. Hou, C. C., Han, L. H., Wang, Q. L., & Hou, C. (2016). Flexural behavior of circular concrete filled steel tubes (CFST) under sustained load and chloride corrosion. Thin-Walled Structures, 107, 182–196.10.1016/j.tws.2016.02.020 ↗
13. Hu, H., & Seracino, R. (2014). Analytical Model for FRP-and-Steel-Confined Circular Concrete Columns in Compression. Journal of Composites for Construction, 18, 4013012.10.1061/(ASCE)CC.1943-5614.0000394 ↗
14. Hu, H. S., Xu, L., Guo, Z. X., & Shahrooz, B. M. (2020). Behavior of eccentrically loaded square spiral-confined high-strength concrete-filled steel tube columns. Engineering Structures, 216, 110743.10.1016/j.engstruct.2020.110743 ↗
15. K. Alrebeh S, Ekmekyapar T,. (2019). Structural performance of short concrete-filled steel tube columns with external and internal stiffening under axial compression. Structures, 20, 702–716.10.1016/j.istruc.2019.06.015 ↗
16. Lai, M. H., & Ho, J. (2014a). Confinement effect of ring-confined concrete-filled-steel-tube columns under uni-axial load. Engineering Structures, 67, 123–141.10.1016/j.engstruct.2014.02.013 ↗
17. Lai, M. H., & Ho, J. C. M. (2014b). Behaviour of uni-axially loaded concrete-filled-steel-tube columns confined by external rings. Structural Design of Tall and Special Buildings, 23, 403–426.10.1002/tal.1046 ↗
18. Lai, M. H., & Ho, J. (2015). Axial strengthening of thin-walled concrete-filled-steel-tube columns by circular steel jackets. Thin-Walled Structures, 97, 11–21.10.1016/j.tws.2015.09.002 ↗
19. Liao, F. Y., Han, L. H., & He, S. H. (2011). Behavior of CFST short column and beam with initial concrete imperfection: Experiments. Journal of Constructional Steel Research, 67, 1922–1935.10.1016/j.jcsr.2011.06.009 ↗
20. Liao, F. Y., Han, L. H., & Zhong, T. (2013). Behaviour of CFST stub columns with initial concrete imperfection: Analysis and calculations. Thin-Walled Structures, 70, 57–69.10.1016/j.tws.2013.04.012 ↗
21. Lu, Y. Y., Li, N., & Li, S. (2014). Behavior of FRP-Confined Concrete-Filled Steel Tube Columns. Polymers, 6, 1333–1349.10.3390/polym6051333 ↗
22. Mander, J., & Priestley, M. (1988). Theoretical stress-strain model for confined concrete. Journal of Structural Engineering, 114, 1804–1826.10.1061/(ASCE)0733-9445(1988)114:8(1804) ↗
23. Na, L., Lu, Y., Shan, L., & Lan, L. (2018). Slenderness effects on concrete-filled steel tube columns confined with CFRP. Journal of Constructional Steel Research, 143, 110–118.10.1016/j.jcsr.2017.12.014 ↗
24. Stephens, M. T., Lehman, D. E., & Roeder, C. W. (2018). Seismic performance modeling of concrete-filled steel tube bridges: Tools and case study. Engineering Structures, 165, 88–105.10.1016/j.engstruct.2018.03.019 ↗
25. Tang, H., Chen, J., Fan, L., Sun, X., & Peng, C. (2020). Experimental investigation of FRP-confined concrete-filled stainless steel tube stub columns under axial compression. Thin-Walled Structures, 146, 106483.10.1016/j.tws.2019.106483 ↗
26. Teng, J. G., Huang, Y. L., Lam, L., & Ye, L. P. (2007). Theoretical model for fiber-reinforced polymer-confined concrete. Journal of Composites for Construction, 11, 201–210.10.1061/(ASCE)1090-0268(2007)11:2(201) ↗
27. Wang, B., Liang, J., & Lu, Z. (2019). Experimental investigation on seismic behavior of square CFT columns with different shear stud layout. Journal of Constructional Steel Research, 153, 130–138.10.1016/j.jcsr.2018.10.004 ↗
28. Wang, G., Wei, Y., Miao, K., Zheng, K., & Dong, F. (2022). Axial compressive behavior of seawater sea-sand coral aggregate concrete-filled circular FRP-steel composite tube columns. Construction and Building Materials, 315, 125737.10.1016/j.conbuildmat.2021.125737 ↗
29. Wang, Y. H., et al. (2021). Coupled ultimate capacity of CFRP confined concrete-filled steel tube columns under compression-bending-torsion load. Structures, 31, 558–575.10.1016/j.istruc.2021.01.086 ↗
30. Wang, Y., Cai, G., Larbi, A. S., Tsavdaridis, K. D., & Ran, J. (2020). Monotonic Axial Compressive Behaviour and Confinement Mechanism of Square CFRP-Steel Tube Confined Concrete. Engineering Structures, 217, 110802.10.1016/j.engstruct.2020.110802 ↗
31. Wei, Y., Bai, J. W., Zhang, Y. R., Miao, K. T., & Zheng, K. Q. (2021). Compressive performance of high-strength seawater and sea sand concrete-filled circular FRP-steel composite tube columns. Engineering Structures, 240, 112357.10.1016/j.engstruct.2021.112357 ↗
32. Wei, Y., Cheng, X., Wu, G., Duan, M., & Wang, L. (2019a). Experimental investigations of concrete-filled steel tubular columns confined with high-strength steel wire. Advances in Structural Engineering, 22, 2771–2784.10.1177/1369433219850645 ↗
33. Wei, Y., Jiang, C., & Wu, Y. F. (2019b). Confinement effectiveness of circular concrete-filled steel tubular columns under axial compression. Journal of Constructional Steel Research, 158, 15–27.10.1016/j.jcsr.2019.03.012 ↗
34. Wei, Y., Zhu, C., Miao, K., Chai, J., & Zheng, K. (2022a). Compressive behavior of rectangular concrete-filled fiber-reinforced polymer and steel composite tube columns with stress-release grooves. Composite Structures, 281, 114984.10.1016/j.compstruct.2021.114984 ↗
35. Wei, Y., Zhu, C., Miao, K., Zheng, K., & Tang, Y. (2022b). Compressive performance of concrete-filled steel tube columns with in-built seawater and sea sand concrete-filled FRP tubes. Composite Structures, 281, 114984.10.1016/j.compstruct.2021.114984 ↗
36. Xu, B., Chen, H. B., Mo, Y. L., & Chen, X. M. (2017). Multi-physical field guided wave simulation for circular concrete-filled steel tubes coupled with piezoelectric patches considering debonding defects. International Journal of Solids and Structures, 122, 25–32.10.1016/j.ijsolstr.2017.05.040 ↗
37. Yu, Q. (2002). Behaviors of FRP-Confined Concrete Columns. New York: Harbin Institute of Technology.
38. Yu, T., Zhang, S., Huang, L., & Chan, C. (2017). Compressive behavior of hybrid double-skin tubular columns with a large rupture strain FRP tube. Composite Structures, 171, 10–18.10.1016/j.compstruct.2017.03.013 ↗
39. Zeng, J. J., Lv, J. F., Lin, G., Guo, Y. C., & Li, L. J. (2018). Compressive behavior of double-tube concrete columns with an outer square FRP tube and an inner circular high-strength steel tube. Construction and Building Materials, 184, 668–680.10.1016/j.conbuildmat.2018.07.034 ↗
40. Zeng, Y., Zhong, H., Liu, C., Tan, H., & Gu, A. B. (2017). Study of creep effects in a long-span concrete-filled steel tube arch bridge Proceedings of the Institution of Civil Engineers. Structures & Buildings, 171, 1–17.
41. Zhang, F., Xia, J., Li, G., Guo, Z., Chang, H., & Wang, K. (2020a). Degradation of Axial Ultimate Load-Bearing Capacity of Circular Thin-Walled Concrete-Filled Steel Tubular Stub Columns after Corrosion. Materials, 13, 795.10.3390/ma13030795 ↗
42. Zhang, T., Zhu, H. H., Zhou, L., & Yan, Z. G. (2021). Multi-level micromechanical analysis of elastic properties of ultra -high performance concrete at high temperatures: Effects of imperfect interface and inclusion size. Composite Structures, 262, 113548.10.1016/j.compstruct.2021.113548 ↗
43. Zhang, Y., Wei, Y., Bai, J., Wu, G., & Dong, Z. (2020b). A novel seawater and sea sand concrete filled FRP-carbon steel composite tube column: Concept and behaviour. Composite Structures, 246, 112421.10.1016/j.compstruct.2020.112421 ↗
44. Zhang, Y. R., Wei, Y., Bai, J. W., & Zhang, Y. X. (2019). Stress-strain model of an FRP-confined concrete filled steel tube under axial compression. Thin-Walled Structures, 142, 149–159.10.1016/j.tws.2019.05.009 ↗
45. Zhang, Y. F., & Zhang, Z. Q. (2015). Analysis on composite action of concrete-filled steel tube columns reinforced by different confining materials. Materials Research Innovations, 19, 236–239.10.1179/1432891715Z.0000000001552 ↗
46. Zheng, J., & Wang, J. (2017). Concrete-filled steel tube arch bridges in China. Engineering, 4, 143–155.10.1016/j.eng.2017.12.003 ↗
47. Zhong, T., Han, L. H., & Zhuang, J. P. (2007). Axial Loading Behavior of CFRP Strengthened Concrete-Filled Steel Tubular Stub Columns. Advances in Structural Engineering, 10, 37–46.10.1260/136943307780150814 ↗
48. Zong, Z. H., Jaishi, B., Ge, J. P., & Ren, W. X. (2005). Dynamic analysis of a half-through concrete-filled steel tubular arch bridge. Engineering Structures, 27, 3–15.10.1016/j.engstruct.2004.08.007 ↗