Threshold angle and valid fracture of the sectored flexural specimen
Source abstract
Abstract
Abstract The sectored flexural specimen was developed over a decade ago to measure the strength of ceramic and glass tubes and cylinders in which flaws on a tube's or cylinder's outer surface are limiters of axial tensile failure stress. Using the specimen's geometry, the associated axial tensile failure stress can be analytically calculated from the failure force measured from simple uniaxial bending, and multiple specimens (and test data) can be harvested from a single tube or cylinder. The sector angles of specimens in previous studies were somewhat arbitrarily chosen and usually produced validly occurring fractures and data; however, if the angle used was too small (relative to the tube's or cylinder's geometry), then undesirable application‐irrelevant edge‐located failures resulted. To avoid such failures in specimen design, a threshold sector angle was identified to guide the selection of a minimum sector angle (and consequential cross section) for any arbitrary sector flexural specimen harvested from a tube or cylinder. If the sector angle of the specimen is larger than the threshold value, then fracture will not occur at a specimen's edge and the measured axial failure stress will be limited by surface‐located flaws on the tube's or cylinder's outer surface.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Non-Destructive Testing Techniques · Ultrasonics and Acoustic Wave Propagation · Hydrogen embrittlement and corrosion behaviors in metals
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Oak Ridge Associated Universities Oak Ridge Tennessee
Oak Ridge National Laboratory Oak Ridge Tennessee
University of North Florida Jacksonville Florida
Funding
Office of Nuclear Energy
References (16)
Show source-provided references
1. ASTM C 1323 · 2016
2. SwabJJ WereszczakAA TiceJ CaspeR KraftRH AdamsJW.Mechanical and thermal properties of advanced ceramics for gun barrel applications. USARL Report # ARL‐TR‐3417 February 2005.
3. 10.1080/1042691060060287910.1080/10426910600602879 ↗
4. Strength of a ceramic sectored flexural test specimen10.1520/JTE100823 ↗
5. 10.4271/2012-01-125210.4271/2012-01-1252 ↗
6. 10.1016/j.jeurceramsoc.2013.12.00510.1016/j.jeurceramsoc.2013.12.005 ↗
7. 10.1111/j.1151-2916.2003.tb03324.x10.1111/j.1151-2916.2003.tb03324.x ↗
8. ASTM C 1684 · 2013
9. 10.1002/9781119040323.ch1010.1002/9781119040323.ch10 ↗
10. 10.1016/j.ijhydene.2017.06.02210.1016/j.ijhydene.2017.06.022 ↗
11. 10.1023/B:JMSC.0000004400.95156.dc10.1023/B:JMSC.0000004400.95156.dc ↗
12. Popov EP · 1976
13. 10.21236/AD027493610.21236/AD0274936 ↗
14. ASTM C 1161 · 2013
15. ASTM C 1499 · 2015
16. ASTM C 1322 · 2015