Does the fatigue loading frequency affect the lithium disilicate glass ceramic inlay-dentin bond strength?

Flavia Zardo Trindade, Fernanda Campos, Caroline Cotes Marinho, Marco Antonio Bottino, Luiz Felipe Valandro, Cornelis J. Kleverlaan

Abstract

The aim of this study was to verify the effect of loading frequency during mechanical cycling on the microtensile bond strength between tooth and ceramic inlays. Twenty-four extracted permanent maxillary molars were standardly prepared (3 mm wide × 4 mm deep) to receive lithium disilicate-based ceramic inlays. After the adhesive cementation, the restored teeth were divided into three groups (n = 8), according to different range of mechanical cycling frequency: control group – water storage, 2.0 Hz group – mechanical cycling at frequency of 2.0 Hz (0–100 N, 1.2 × 106 cycles, water 37 °C), and 6.7 Hz group – mechanical cycling at frequency of 6.7 Hz (0–100 N, 1.2 × 106 cycles, water 37 °C). The teeth were then cut into microbars (1 × 1 mm, non-trimming method), which were tested under microtensile (MTBS) loading. The failure mode was classified and the data were analyzed by one-way ANOVA. The mean bond strength value of the control group was the highest and the values of the cycled groups were 15% lower, however the groups were statistically similar (p = 0.58). Chi-square test showed no statistical difference among the groups regarding the pre-test failures (p = 0.17). For all groups, the most frequent failure type was mode 1 (adhesive at the interface ceramic/cement) and mode 2 (mixed failure). Loading frequencies up to 6.7 Hz had no effect on the lithium disilicate glass ceramic inlay-dentin bond strength.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Dental materials and restorations · Dental Research and COVID-19 · Dental Implant Techniques and Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (50)

Show source-provided references
1. Conservative posterior ceramic restorations: a literature review10.1016/0022-3913(90)90316-5 ↗
2. Porcelain inlay: a historical view
3. Ceramics in dentistry: historical roots and current perspectives10.1016/S0022-3913(96)90413-8 ↗
4. Marginal adaptation of different types of all-ceramic partial coverage restorations after exposure to an artificial mouth10.1038/sj.bdj.4813036 ↗
5. Effect of resin cement type on the microtensile bond strength to lithium disilicate ceramic and dentin using different test assemblies
6. Effects of repeated processing on the strength and microstructure of a heat-pressed dental ceramic10.1016/j.prosdent.2014.06.015 ↗
7. Microtensile bond strength of a resin cement to feldpathic ceramic after different etching and silanization regimens in dry and aged conditions10.1016/j.dental.2006.11.011 ↗
8. Marginal breakdown of fired ceramic inlays cemented with glass polyalkenoate (ionomer) cement or resin composite10.1016/0300-5712(94)90055-8 ↗
9. Microtensile bond strength testing of luting cements to prefabricated CAD/CAM ceramic and composite blocks10.1016/S0109-5641(02)00107-0 ↗
10. Fracture frequency of all-ceramic crowns during dynamic loading in a chewing simulator using different loading and luting protocols10.1016/j.dental.2008.02.019 ↗
11. The wear of dental amalgam in an artificial mouth: a clinical correlation10.1016/S0109-5641(85)80050-6 ↗
12. Wear of composite resin veneering materials in a dual-axis chewing simulator10.1046/j.1365-2842.1999.00416.x ↗
13. Wear of ceramic inlays, their enamel antagonists, and luting cements10.1016/0022-3913(93)90192-Q ↗
14. Approach for valuating the influence of laboratory simulation10.1016/j.dental.2008.08.009 ↗
15. Fracture resistance of different partial-coverage ceramic molar restorations: an in vitro investigation10.14219/jada.archive.2006.0224 ↗
16. Stress fatigue: basic principles and prosthodontic implications
17. Functional occlusal forces: an investigation by telemetry10.1016/0022-3913(78)90042-2 ↗
18. Natural bites, food consistency and feeding behaviour in man10.1016/0003-9969(95)00112-3 ↗
19. Quantification of human chewing-cycle kinematics10.1016/S0003-9969(00)00015-7 ↗
20. The regulation of masticatory function and food bolus formation10.1111/j.1365-2842.2006.01626.x ↗
21. Mandibular movements of young adults recorded by intraorally placed light-emitting diodes10.1016/0022-3913(79)90199-9 ↗
22. Marginal and internal fit of heat pressed versus CAD/CAM fabricated all-ceramic onlays after exposure to thermo-mechanical fatigue10.1016/j.jdent.2013.10.002 ↗
23. The effect of mechanical loading on the cusp defection of premolars restored with direct and indirect techniques10.5005/jp-journals-10024-1491 ↗
24. Marginal adaptation of ceramic and composite inlays in minimally invasive mod cavities10.1007/s00784-013-0988-1 ↗
25. Effect of storage times and mechanical load cycling on dentin bond strength of conventional and self-adhesive resin luting cements10.1016/j.prosdent.2013.07.016 ↗
26. Effect of tooth brush abrasion and thermo-mechanical loading on direct and indirect veneer restorations10.1007/s00784-014-1209-2 ↗
27. In vitro performance of one- and two-piece zirconia implant systems for anterior application10.1016/j.jdent.2016.08.004 ↗
28. Ceramic inlays: effect of mechanical cycling and ceramic type on restoration-dentin bond strength10.2341/14-155-L ↗
29. Fiber post cementation strategies: effect of mechanical cycling on push-out bond strength and cement polymerization stress
30. Microtensile bond strength between indirect composite resin inlays and dentin: effect of cementation strategy and mechanical aging
31. Relationship between surface-area for adhesion and tensile bond strength - evaluation of a micro-tensile bond test10.1016/0109-5641(94)90067-1 ↗
32. Microtensile test in dental research. controversial aspects in statistical analysis (experimental unit and premature failures)10.14295/bds.2013.v16i3.869 ↗
33. Pressable feldspathic inlays in premolars: effect of cementation strategy and mechanical cycling on the adhesive bond between dentin and restoration
34. Evaluation of resin bond strength to yttria-stabilized tetragonal zirconia and framework marginal fit: comparison of different surface conditionings10.2341/12-269-L ↗
35. Adhesion to Y-TZP ceramic: study of silica nanofilm coating on the surface of Y-TZP10.1002/jbm.b.33184 ↗
36. Microtensile bond strength of lithium disilicate ceramics to resin adhesives
37. Effects of surface treatments, thermocycling, and cyclic loading on the bond strength of a resin cement bonded to a lithium disilicate glass ceramic10.2341/11-076-L ↗
38. Adhesive strength of self-adhesive resins to lithium disilicate ceramic and dentin: effect of dentin chelating agents10.1007/s10266-014-0180-3 ↗
39. Effect of acid neutralization and mechanical cycling on the microtensile bond strength of glass-ceramic inlays10.2341/08-68 ↗
40. Influence of loading frequency on implant failure under cyclic fatigue conditions10.1016/j.dental.2009.06.015 ↗
41. Fatigue of restorative materials10.1177/10454411010120040501 ↗
42. A comparison of fatigue crack growth in resin composite, dentin and the interface10.1016/j.dental.2006.05.003 ↗
43. Long-term durability of dentin bonds made with a self-etching primer, in vivo10.1177/00220345990780041101 ↗
44. Cuspal deflection in molars in relation to endodontic and restorative procedures10.1016/S0099-2399(06)81095-2 ↗
45. In vitro cuspal deflection and microleakage of maxillary premolars restored with novel low-shrink dental composites10.1016/j.dental.2004.05.005 ↗
46. Fracture resistance of prepared teeth restored with bonded inlay restorations10.1016/S0022-3913(03)00173-2 ↗
47. The influence of elastic modulus of inlay materials on stress distribution and fracture of premolars10.2341/13-092-L ↗
48. Influence of frequency on shear fatigue strength of resin composite to enamel bonds using self-etch adhesives10.1016/j.jmbbm.2016.05.017 ↗
49. Effect of frequency on the fatigue strength of dentin bonds10.2334/josnusd.16-0229 ↗
50. Adhesion to tooth structure: a critical review of "macro" test methods10.1016/j.dental.2009.11.150 ↗