An oligomeric switch that rapidly decreases the peel strength of a pressure-sensitive adhesive
Source abstract
Abstract
Abstract The development of medical pressure-sensitive adhesives that possess high peel force when in contact with the skin and low peel force when removed from the skin is a noteworthy area of research. The means by which the peel force has been modulated in the past has included physical approaches (peel angle, deformation of skin, substrate material, etc.) and chemical processes that implement a “switch” that can be activated during removal to significantly reduce the peel force of the adhesive. Herein, we report the application of oligo(glycerol sebacate) (OGS) as an adhesive “switch” that is activated via the use of isopropyl alcohol (IPA) to promote a rapid decrease in peel force during removal of a medical pressure-sensitive adhesive. Furthermore the decrease in peel force is approximately 90%, and occurs on a clinically manageable time-scale (20 s). The technology found within this paper is amenable to current manufacturing processes and is ready to be implemented in medical pressure-sensitive adhesives so that healthcare providers, patients, and consumers might have a means of diminishing pain and trauma during the removal of bandages and/or medical dressings.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Surgical Sutures and Adhesives · Advanced Sensor and Energy Harvesting Materials · Polymer Surface Interaction Studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (32)
Show source-provided references
1. Smith · J Am Inst Conserv · 1984 · 23 · 10110.1179/019713684806028241 ↗
2. 〈http://www.web.mit.edu/invent/iow/dickson.html〉 2013.
3. Hollinworth · J Wound Care · 2000 · 9 · 36910.12968/jowc.2000.9.8.26282 ↗
4. Waring · Wounds UK · 2008 · 4 · 35
5. LeBlanc · Adv Skin Wound Care · 2009 · 22 · 32510.1097/01.ASW.0000305484.60616.e8 ↗
6. Hess · Adv Skin Wound Care · 2004 · 17 · 277
7. Karp · Nature · 2011 · 477 · 4210.1038/477042a ↗
8. 3M Company Introducing 3M Kind Removal Silicone Tape. 3M Company, St. Paul, MN 2012.
9. Mason · Ostomy Wound Manage · 1997 · 43 · 26
10. Dykes · J Wound Care · 2001 · 10 · 710.12968/jowc.2001.10.2.26054 ↗
11. Cutting · J Wound Care · 2008 · 17 · 15710.12968/jowc.2008.17.4.28836 ↗
12. Bianchi · Br J Community Nurs · 2008 · 13 · S2610.12968/bjcn.2008.13.Sup1.28684 ↗
13. White · Wounds UK · 2005 · 1 · 104
14. 〈www.un.org/esa/population/publications/worldageing19502050/pdf/80chapterii.pdf〉 2002.
15. Fabrico,®, A Division of EIS. Protecting skin with low trauma adhesives. Fabrico® Company, Kennesaw, GA 2014.
16. White · Br J Nurs · 2003 · 12 · 118610.12968/bjon.2003.12.20.11841 ↗
17. Lin · Biomaterials · 2001 · 22 · 299910.1016/S0142-9612(01)00046-1 ↗
18. Mahdavi · Proc Natl Acad Sci · 2008 · 105 · 230710.1073/pnas.0712117105 ↗
19. Karp · Nat Commun · 2013 · 4 · 1
20. Laulicht · Proc Natl Acad Sci · 2012 · 109 · 1880310.1073/pnas.1216071109 ↗
21. Wang · Nat Biotechnol · 2002 · 20 · 60210.1038/nbt0602-602 ↗
22. Crapo · J Biomed Mater Res · 2008 · 86 · 35410.1002/jbm.a.31598 ↗
23. Wu · Nat Med · 2012 · 18 · 114810.1038/nm.2821 ↗
24. Crapo · Biomaterials · 2010 · 31 · 162610.1016/j.biomaterials.2009.11.035 ↗
25. Lee · Proc Natl Acad Sci USA · 2011 · 108 · 270510.1073/pnas.1017834108 ↗
26. Sun · Biomaterials · 2009 · 30 · 520910.1016/j.biomaterials.2009.06.007 ↗
27. Hagandora · Tissue Eng · 2013 · 19 · 72910.1089/ten.tea.2012.0304 ↗
28. Zaky · Tissue Eng · 2014 · 20 · 4510.1089/ten.tea.2013.0172 ↗
29. Gao · Tissue Eng · 2006 · 12 · 91710.1089/ten.2006.12.917 ↗
30. Biocompatibility studies ISO 10993-10:2010 and ISO 10993-5:2009 describe “Biological Evaluation of Medical Devices, Part 10: Tests for Irritation and Skin Sensitization” and “Biological Evaluation of Medical Devices, Part 5: Tests for In Vitro Cytotoxicity,” respectively.
31. International standard ASTM-D3330 method A provides a protocol for measuring the peel strength of pressure-sensitive adhesives when peeled at a 180° peel angle, a peel rate of 5mm/s, a temperature of 23±1°C, and a relative humidity of 50±5% 2010.
32. Boyce · Infection Control Hospital Epidemiol · 2000 · 21 · 43810.1086/501784 ↗