journal article·2022-12

Adhesively bonding a reusable PZT transducer for structural health monitoring (SHM) with an ethylene-acrylic acid copolymer adhesive

Qijian Liu, Yuan Chai, Yishou Wang, Hu Sun, Xinlin Qing

Publisher page

Abstract

A novel approach to bonding a piezoelectric lead zirconate titanate (PZT) transducer on a structure for health monitoring was developed to replace the traditional method of bonding PZT permanently. Several experiments demonstrated the feasibility of a reusable PZT transducer based on the adhesive film made using ethylene-acrylic acid copolymer (EAA). Additionally, the adhesion performance of using EAA for bonding PZT at different temperatures and the effect of heating temperature on reusable PZT transducer removal from the test structure was investigated. The effect of adhesive thickness on the mechanical property and the performance of PZT has also been explained. Experimental results showed that the optimized heating temperature of the adhesive film was around 140 °C due to the stability of PZT being sensitive to high temperature and the ease of removing PZT from the test structure without damage. An analysis of the varying thickness of the adhesive layer on PZT performance indicated that the amplitude of Lamb wave signals changed with adhesive thickness, increasing with greater adhesive thickness. Therefore, the adhesive layer made using EAA provides a new approach to conducting Lamb wave-based structural health monitoring.
Source: expertdata · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Ultrasonics and Acoustic Wave Propagation · Structural Health Monitoring Techniques · Acoustic Wave Resonator Technologies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (20)

Show source-provided references
1. A review of nonlinear dynamics applications to structural health monitoring10.1002/stc.215 ↗
2. Structural health monitoring in the railway industry: a review10.1177/1475921705049764 ↗
3. State-of-the-Art review of technologies for pipe structural health monitoring10.1109/JSEN.2011.2181161 ↗
4. Piezoelectric transducer-based structural health monitoring for aircraft applications10.3390/s19030545 ↗
5. Guided Lamb waves for identification of damage in composite structures: a review10.1016/j.jsv.2006.01.020 ↗
6. A novel damage index for damage identification using guided waves with application in laminated composites10.1088/0964-1726/23/9/095015 ↗
7. Structural Health Monitoring system based on a concept of Lamb wave focusing by the piezoelectric array10.1016/j.ymssp.2018.02.008 ↗
8. Effects of adhesive thickness on the Lamb wave pitch-catch signal using bonded piezoelectric wafer transducers10.1088/0964-1726/25/8/085014 ↗
9. Effect of adhesive on the performance of piezoelectric elements used to monitor structural health10.1016/j.ijadhadh.2005.10.002 ↗
10. Influence of interface degradation on the performance of piezoelectric actuators10.1177/1045389X09341198 ↗
11. Adhesive interface layer effects in PZT-induced Lamb wave propagation10.1088/0964-1726/19/2/025006 ↗
12. Environmental and operational conditions effects on Lamb wave based structural health monitoring systems: a review10.1016/j.ultras.2020.106114 ↗
13. Structural health monitoring with piezoelectric wafer active sensors for space applications10.2514/1.26141 ↗
14. Pitch-catch active sensing methods in structural health monitoring for aircraft structures10.1177/1475921707081979 ↗
15. Detection of cuts and impact damage at the aircraft wing slat by using Lamb wave method10.1016/j.measurement.2015.02.007 ↗
16. Quantitative damage image construction in plate structures using a circular PZT array and lamb waves10.1016/j.sna.2014.04.016 ↗
17. Tuned lamb wave excitation and detection with piezoelectric wafer active sensors for structural health monitoring10.1177/1045389X05050106 ↗
18. Properties of ethylene-acrylic acid copolymers10.1021/ma60003a009 ↗
19. Evaluation of ethylene–acrylic acid copolymer (EAA)-modified asphalt: fundamental investigations on mechanical and rheological properties10.1016/j.conbuildmat.2015.04.049 ↗
20. Reusable piezoelectric transducer for structural health monitoring using both Lamb wave and electromechanical impedance modes10.1177/1045389X20942843 ↗