Joints with bars glued-in softwood laminated timber subjected to climatic cycles

D. Otero-Chans, J. Estévez-Cimadevila, E. Martín-Gutiérrez

Abstract

The effect of climatic cycles (extreme temperatures and humidity) on the performance of joints made with threaded steel rods glued by two-component epoxy adhesive in softwood glulam timber is studied. Short-term tests have been made on three types of specimens: standard condition specimens (20 °C/65%RH), specimens subjected to extreme temperature and humidity during its storage in climatic chamber in service load situation, and specimens in similar unloaded situation. The load capacity, the failure modes and the load-deflection curves have been compared for the different types of specimens. The obtained results do not show a clear influence of the previous exposition to extreme climatic situations in the strength of the joint. On the contrary, the stiffness of the joints, especially those with longer anchorage length, has been reduced up to 35% in the specimens that were previously subjected to climatic changes, both unloaded and in load service situation.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Wood Treatment and Properties · Natural Fiber Reinforced Composites · Lignin and Wood Chemistry

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (48)

Show source-provided references
1. Strengthening of timber structures with glued-in rods10.1016/j.conbuildmat.2015.03.097 ↗
2. State-of-the-art review on timber connections with glued-in steel rods10.1617/s11527-010-9682-9 ↗
3. Timber joints with multiple glued-in steel rods10.1080/00218464.2015.1099098 ↗
4. Provisions for ductile behavior of timber-to-steel connections with multiple glued-in rods10.1061/(ASCE)ST.1943-541X.0000735 ↗
5. Timber frame moment joints with glued-in steel rods. II: experimental investigation of long-term performance10.1061/(ASCE)ST.1943-541X.0000517 ↗
6. Pull-compression tests on glued-in metric thread rods parallel to grain in glulam and laminated veneer lumber of different timber species10.1007/s00107-015-1001-2 ↗
7. Resistance-curves and wood variability: application of glued-in-rod10.1016/j.ijadhadh.2016.04.015 ↗
8. Mechanical performance of polyurethane and epoxy adhesives in connections with glued-in rods at elevated temperatures10.15376/biores.11.4.8200-8214 ↗
9. Adhesively Bonded Hardwood Joints under Room Temperature and Elevated Temperatures10.1080/00218464.2013.836968 ↗
10. Influence of timber density on the axial strength of joints made with glued-in steel rods: an experimental approach10.1016/j.ijadhadh.2010.03.004 ↗
11. Influence of the geometric and material characteristics on the strength of glued joints made in chestnut timber10.1016/j.matdes.2008.06.041 ↗
12. Glued joints in hardwood timber10.1016/j.ijadhadh.2008.04.008 ↗
13. Experimental behaviour of threaded steel rods glued into high-density hardwood10.1016/j.ijadhadh.2006.01.006 ↗
14. Tensile and fatigue investigations of timber joints with glued-in FRP rods
15. Withdrawal strength of threaded steel rods glued with epoxy in wood10.1016/j.ijadhadh.2013.02.008 ↗
16. Experimental assessment of the pull-out strength of single rods bonded in glulam parallel to the grain10.1007/s00107-008-0263-3 ↗
17. Behaviour of joints with bonded-in steel bars loaded parallel to the grain of timber elements10.1016/j.conbuildmat.2010.11.026 ↗
18. Pull-out strength of axially loaded steel rods bonded in glulam parallel to the grain10.1617/s11527-006-9111-2 ↗
19. Stepinac M, Rajcic V, Hunger F, van de Kuilen J-W, Tomasi R, Serrano E. CIBW18/46-7-10: Comparison of design rules for glued-in rods and design rule proposal for implementation in European standards. in: Proceedings of the CIB-W18 Meeting Forty-Six, Vancouver, Canada; 2013.
20. Effect of temperature on the mechanical performance of glued-in rods in timber structures10.1016/j.ijadhadh.2014.10.006 ↗
21. Mixed mode fracture of glued-in rods in timber structures. A new approach based on equivalent LEFM10.1007/s10704-014-9986-9 ↗
22. Gustafsson PJ, Serrano E, Aicher S, Johansson CJ. A strength design equation for glued-in rods. in: Proceedings of the International RILEM Symposium, Germany, p 323-332; 2001.
23. UNE-EN 1995-1-1:2016. Eurocode 5: Design of timber structures - Part 1-1: General - Common rules and rules for buildings. European Committee for Standardization Brussels, Belgium.
24. Larse HJ Properties affecting reliability design of timber structures. COST E24 Seminar on Reliability of timber structures Coimbra, Portugal, 4-5 May 2001.
25. Wood as a natural smart material10.1007/s00226-013-0611-2 ↗
26. Modeling of the viscoelastic mechano-sorptive behavior in wood10.1007/s11043-012-9171-3 ↗
27. Sorin E, Lanata F, Boudaud C. Behaviour of timber structures under variable environment through long-term monitoring. in: Proceedings of the World Conference on Timber Engineering, Vienna, Austria. ISBN: 978-390303900-1; 2016.
28. Creep behavior of wood under cyclic moisture changes: interaction between load effect and moisture effect10.1007/s10086-016-1565-4 ↗
29. Behaviour of creep of timber beams under natural environmental conditions10.2495/HPSM140441 ↗
30. Aicher S, Dill-Langer G. Influence of moisture, temperature and load duration on performance of glued-in rods. in: Proceedings of the international RILEM symposium on joints in timber structures, Stuttgart, Germany, p.383-392; 2001.
31. Creep performance of glued-in rods joints in controlled and variable climate conditions10.1016/j.ijadhadh.2017.02.012 ↗
32. Rehabilitation of timber structures: novel test method to assess the durability of bonded-in rod connections10.1617/s11527-011-9760-7 ↗
33. Harris S Fire Resistance of Epoxy-grouted Steel Rod Connections in Laminated Veneer Lumber (LVL). Fire Engineering Research Report 04/7. Ed. University of Canterbury, New Zealand. June 2004.
34. Influence of elevated temperature on glued-in steel rods for timber elements10.1016/j.conbuildmat.2017.04.038 ↗
35. Heat flow in a glulam joist with a glued-in steel rod subjected to variable ambient temperature
36. Effect of timber moisture content on bonded-in rods10.1016/S0950-0618(00)00066-0 ↗
37. Mechanical performance of full scale steel-timber epoxy joints after exposure to extreme environmental conditions10.1016/j.ijadhadh.2014.05.005 ↗
38. CEN EN 14080. Timber structures. Glued laminated timber and glued solid timber. Requirements. European Committee for Standardization Brussels, Belgium; 2013.
39. UNE EN 1993–1-8:2008. Eurocode 3: Design of steel structures – Part 1–8: Design of joints. Asociación Española de Normalización y Certificación (AENOR).
40. European Technical Approval ETA-04/0027. Deutches Institut für Bautechnick, Germany, 20 May 2009.
41. Pierfrancesco V Realistic shear assessment and novel strengthening of existing concrete bridges. Doctoral Thesis. University of Bath. November 2009.
42. CEN EN ISO 9142:3003. Adhesives. Guide to the selection of standard laboratory ageing conditions for testing bonded joints European Committee for Standardization Brussels, Belgium. (June 2004).
43. UNE EN 302-3:2005/A1:2006. Adhesives for load-bearing timber structures - Test methods - Part 3: Determination of the effect of acid damage to wood fibres by temperature and humidity cycling on the transverse tensile strength.
44. Kollman F. Tecnología de la Madera y sus aplicaciones, Tomo 1. Ministerio de Agricultura, Instituto Forestal de Investigaciones y Experiencias, IFIE, Madrid; 1959.
45. CEN EN 1990:2003/a1:2010. Eurocode - Basis of structural design. European Committee for Standardization Brussels, Belgium.
46. Research on thermal conductivity of the wood and Analysis of results obtained by the hot wire method10.1007/s40799-016-0096-7 ↗
47. Martín-Gutiérrez E, Estévez-Cimadevila J, Otero-Chans D Durability of joints made with threaded steel rods glued in chestnut timber - An experimental approach. Composites Part B, DOI:10.1016/j.compositesb.2016.10.010.10.1016/j.compositesb.2016.10.010 ↗
48. Influence of geometric and mechanical parameters on stress states caused by threaded rods glued in wood10.1007/s00107-013-0678-3 ↗