journal article·2020-04

Effects of glue-line thickness and manufacturing defects on the pull-out behavior of glued-in rods

Bo-Han Xu, Jing-Hua Guo, Abdelhamid Bouchaïr

Publisher page

Abstract

Abstract Glued-in rods are offering to timber joints not only enhanced stiffness and high load capacity but also aesthetical appearance and good fire resistance. However, no consistent manufacturing process and quality control method is reported in the literature. It is necessary to estimate the effect of possible manufacturing defects on pull-out behavior of glued-in rods. This paper presents the experimental results on glued-in rods with two types of possible manufacturing defects on site: eccentric position of rod in hole and inclined setting of rod in hole. The effect of manufacturing defects was investigated on the samples with three different glue-line thicknesses. A finite element model considering the elastic behavior of materials with their measured elastic parameters and dimensions is proposed. It illustrates the evolution of the stress distribution in the connection zone and explains the observed brittle failure modes.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Wood Treatment and Properties · Fire effects on concrete materials · Mechanical Behavior of Composites

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (43)

Show source-provided references
1. Bonded-in rod connections for timber structures―development of design methods and test observations10.1016/S0143-7496(01)00036-7 ↗
2. A review of moment-resistant structural timber connections10.1680/istbu.1998.30909 ↗
3. Timber frame moment joints with glued-in steel rods. I: Design10.1061/(ASCE)ST.1943-541X.0000419 ↗
4. Analytical study and finite element modeling of timber connections with glued-in rods in bending10.1016/j.conbuildmat.2012.02.087 ↗
5. Reduction of perpendicular-to-grain stresses in the apex zone of curved beams using glued-in rods10.1617/s11527-009-9503-1 ↗
6. Strengthening of timber structures with glued-in rods10.1016/j.conbuildmat.2015.03.097 ↗
7. Improved timber connections using bonded-in GFRP rods
8. Behaviour of joints with bonded-in steel bars loaded parallel to the grain of timber elements10.1016/j.conbuildmat.2010.11.026 ↗
9. Experimental assessment of the pull-out strength of single rods bonded in glulam parallel to the grain10.1007/s00107-008-0263-3 ↗
10. Influence of the geometric and material characteristics on the strength of glued joints made in chestnut timber10.1016/j.matdes.2008.06.041 ↗
11. Influence of glue rheology and joint thickness on the strength of bonded-in rods10.1007/s00107-003-0387-4 ↗
12. Geometric parameters which affect the short term resistance of an axially loaded glued-in rod10.1617/s11527-006-9155-3 ↗
13. Orientation of bars glued on glued laminated products: parallel vs. perpendicular10.1016/j.compositesb.2014.02.028 ↗
14. Effect of rod-to-grain angle on capacity and stiffness of axially and laterally loaded long threaded rods in timber joints10.1007/s00107-018-1314-z ↗
15. Pull-out strength of axially loaded steel rods bonded in glulam parallel to the grain10.1617/s11527-006-9111-2 ↗
16. Geometric parameters which affect the sort term resistance of an axially loaded glued-in rod10.1617/s11527-006-9155-3 ↗
17. Experimental assessment of the pull-out strength of single rods bonded in glulam parallel to the grain10.1007/s00107-008-0263-3 ↗
18. Nie · 2012
19. Bengtsson · 2002
20. Glued-in rods for timber structures — an experimental study of softening behaviour10.1007/BF02480593 ↗
21. Effects of spacing and edge distance on the axial strength of glued in rods
22. DIN · 2008
23. Pull-out strength of steel rods bonded into mengkulang (tarrietia javanica) glulam at five different angles to the grain
24. Pull-out strength of axially loaded steel rods bonded in glulam perpendicular to the grain10.1617/s11527-006-9214-9 ↗
25. State-of-the-art review on timber connections with glued-in steel rods10.1617/s11527-010-9682-9 ↗
26. Adhesively bonded timber joints - Do defects matter?10.1016/j.ijadhadh.2014.07.003 ↗
27. Test methods for glued-in rods for timber structures
28. Influence of manufacturing methods and imperfections on the load capacity of glued-in rods
29. Influence of imperfections on the load capacity and stiffness of glued-in rod connections10.1016/j.conbuildmat.2019.07.278 ↗
30. The impact of defects on the capacity of timber joints with glued-in rods10.1016/j.ijadhadh.2015.11.002 ↗
31. An analytical method for the determination of end-of-hole profiling in bonded-in rod connections for structural timber
32. Adhesive systems for structural connections in timber10.1016/S0143-7496(00)00049-X ↗
33. Buchanan · 1999
34. CEN EN 1995-1-1 · 2004
35. Determination of shear modulus on construction size timber10.1007/BF00702796 ↗
36. CEN · 2004
37. Shear strength and perpendicular-to-grain tensile strength of defect-free Scots pine wood from mature stands in Finland and Sweden10.1007/s00226-007-0151-8 ↗
38. Withdrawal strength of threaded steel rods glued with epoxy in wood10.1016/j.ijadhadh.2013.02.008 ↗
39. CEN EN 26891 · 1991
40. CEN prEN-1995-2 · 2003
41. Glued-in rods for timber structures – a 3D model and finite element parameter studies10.1016/S0143-7496(00)00043-9 ↗
42. Broughton JG. Main test series: Verification of design calculations – for the development of design procedures for repairs. Low intrusion conservation systems for timber structures (LICONS), Task 4.1, CRAF-1999-71216.
43. Rods glued in engineered hardwood products − Part II: numerical modelling and capacity prediction10.1016/j.ijadhadh.2018.05.004 ↗