journal article·2008-10

Overheat induced failure of a steel tube in an electric arc furnace (EAF) cooling system

A. Vazdirvanidis, G. Pantazopoulos, A. Louvaris

Engineering Failure Analysis· Volume 15· Issue 7
Publisher page

Abstract

Abstract A fractured steel tube component from the cooling system of an electric-arc-furnace (EAF) of a steelmaking plant was received with a request of a failure analysis investigation. The specific damage caused steam leakage and led to the furnace shut-down for maintenance resulting in significant steel production delays. Visual inspection, optical microscopy and microhardness testing were used as the principal investigation techniques in the present study. Prolonged overheating at high temperatures has led to decarburization and weakening of the surface of the tube. This resulted further in subsequent cracking due to the operating tensile stresses developed from steep thermal gradient and thermal cycling suggesting that the most probable failure mechanism is thermal fatigue.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: High Temperature Alloys and Creep · Metallurgical Processes and Thermodynamics · Metal Alloys Wear and Properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (8)

Show source-provided references
1. Jones · 1993
2. An overheat boiler tube failure10.1361/15477020522997 ↗
3. Failure analysis of cold and hot reheater tubes10.1016/j.engfailanal.2006.03.007 ↗
4. Corrosive degradation and failure of vertical furnace wall tubes of a boiler10.1016/S1350-6307(97)00015-0 ↗
5. Experience on in-service damage in power plant components10.1016/j.engfailanal.2006.12.007 ↗
6. High temperature failure of a cast soot blower lance tube nozzle10.1361/15477020522988 ↗
7. BS EN ISO 6507-1:2005: Metallic materials. Vickers hardness test. Part 1: test method. ISO, Geneva, Switzerland.