journal article·2008-04

Failure analysis of a bolt in a scaffolding system

R. Lacalle, S. Cicero, D. Ferreño, J.A. Álvarez

Engineering Failure Analysis· Volume 15· Issue 3
Publisher page

Abstract

Abstract This paper analyses the failure of a bolt which sustained a scaffolding during a construction process. The work performed begins with the fractographic analysis of the failure section and continues with a structural integrity assessment using the European FITNET FFS procedure. The main conclusion is that failure occurred due to the superposition of an overloading which the scaffolding was not designed for and an environmental assisted cracking process.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Construction Engineering and Safety · Structural Response to Dynamic Loads · Risk and Safety Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (6)

Show source-provided references
1. ASTM E8-00b. Standard test methods for tension testing of metallic materials. Annual book of ASTM standards, vol 03.01.
2. ASTM El 820-99, Standard test method for measurement of fracture toughness. Annual book of ASTM standards, vol 03.01.
3. Ossa · Eng Fail Anal · 2006 · 13 · 117710.1016/j.engfailanal.2005.04.008 ↗
4. Walter GH, Hendrickson RH, Zipp RD. Anomalous fractures of diesel engine bearing cap bolts. Handbook of case histories in failure analysis, vol. 2; 1993.10.31399/asm.fach.v02.c9001377 ↗
5. Champagne VK. Failed bolts from an army tank recoil mechanism. Handbook of case histories in failure analysis, vol. 2; 1993.10.31399/asm.fach.v02.c9001379 ↗
6. European fitness-for-service network. FITNET fitness-for-service procedure. GIRT-CT-2001-05071.