journal article·2023-11

A case study of glass insulator pin failure in 500 kV transmission line

José Alexander Araújo, Giorgio André Brito Oliveira, Miguel Angel Garcia, Neyson Martins Mendonça, Cosme Roberto Moreira da Silva, Paulo Augusto Nepomuceno Garcia, Remy Kalombo Badibanga

Publisher page

Abstract

No abstract is available for this record. The assistant can identify its topic from the title, but cannot infer the study’s results.

Source: Not provided · Quality: missing

Research context

OpenAlex topics: Electrical Fault Detection and Protection · Lightning and Electromagnetic Phenomena · High voltage insulation and dielectric phenomena

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (35)

Show source-provided references
1. Frontin S de O. Prospecção e Hierarquização de Inovações Tecnológicas Aplicadas a Linhas de Transmissão, 2011.
2. R.S. Gorur, High-Voltage Transmission. Elsevier Inc.; 2005, doi: 10.1016/B978-012170960-0/50054-2.10.1016/B978-012170960-0/50054-2 ↗
3. J.C. Castro, G. Aponte, V.H. Sánchez, M. Castro, A. Espinosa, N. Rosales, Colombian experience on insulation pollution level measurement applying the ESDD methodology, in: 2006 IEEE PES Transm Distrib Conf Expo Lat Am TDC’06 2006, pp. 1–5. doi: 10.1109/TDCLA.2006.311620.10.1109/TDCLA.2006.311620 ↗
4. N. Bashir, H. Ahmad, Ageing of transmission line insulators: The past, present and future, in: PECon 2008 - 2008 IEEE 2nd Int Power Energy Conf 2008, pp. 30–34, doi: 10.1109/PECON.2008.4762440.10.1109/PECON.2008.4762440 ↗
5. A. Nekahi, S.G. Mcmeekin, Distribution along a Polymeric Insulator 2015, pp. 612–615.
6. Flashover problems caused by ice build-up on insulators10.1109/57.372510 ↗
7. Dynamic arc modeling of pollution flashover of insulators under dc voltage10.1109/14.212246 ↗
8. Flashover phenomena of polluted insulators10.1049/ip-c.1984.0022 ↗
9. S.W. Han, I.H. Choi, D. Lee Il, Thermal impact characteristics by forest fire on porcelain insulators for transmission lines, in: 2007 Electr Insul Conf Electr Manuf Expo, EEIC 2007 2007, pp. 118–121, doi: 10.1109/EEIC.2007.4562601.10.1109/EEIC.2007.4562601 ↗
10. Electrical field behavior of transmission line insulators in polluted area
11. S. Deb, R. Ghosh, S. Dutta, S. Dalai, B. Chatterjee, Condition monitoring of 11kV porcelain pin insulator extracting surface current from total leakage current, in: 2017 3rd Int Conf Cond Assess Tech Electr Syst CATCON 2017 - Proc 2018, 2018, pp. 403–406, doi: 10.1109/CATCON.2017.8280253.10.1109/CATCON.2017.8280253 ↗
12. Overview of the condition monitoring of overhead lines10.1016/S0378-7796(99)00037-1 ↗
13. S.C. Oliveira, E. Fontana, F.J.do M. de Melo Cavalcanti, Leakage current activity on glass-type insulators of overhead transmission lines in the ortheast region of Brazil. IEEE Trans Power Deliv 2009;24:822–7, doi: 10.1109/TPWRD.2008.2002872.10.1109/TPWRD.2008.2002872 ↗
14. A comparative study on the failure analysis of field failed high voltage composite insulator core rods and recommendation of composite insulators: A review10.1016/j.engfailanal.2022.106369 ↗
15. Instrumental inspection methodology to evaluate corrosion in transmission line glass insulator metallic pins
16. D. Hao, Y. Wang, D. Yang, Electrolytic Corrosion Charge Monitoring on the Hardware of Porcelain and Glass Insulators on HVDC Overhead Lines, in: 2020 10th Int Conf Power Energy Syst ICPES 2020, 2020, p. 56–60, doi: 10.1109/ICPES51309.2020.9349693.10.1109/ICPES51309.2020.9349693 ↗
17. Feasibility study on PRTV of suppressing insulator iron cap from corrosion
18. A machine learning approach for condition monitoring of high voltage insulators in polluted environments
19. Classifying insulator conditions of room temperature vulcanized coated glass insulators under different coating damage modes
20. Insulation failure caused by special pollution around industrial environments10.1016/j.engfailanal.2019.04.034 ↗
21. IEC: “Guide for the selection of insulators in respect of polluted conditions”, Publication 60815, First ed. 1986.
22. Sediver toughened glass insulators for HVAC applications C11-2017-2, 2017.
23. Mechanism of corrosion in porcelain insulators and its effect on the lifetime10.3390/app10010423 ↗
24. Corrosion mechanisms for zinc exposed to the atmosphere10.1149/1.2096868 ↗
25. Revie · 2008
26. Effect of pH on the corrosion products and corrosion rate of zinc in oxygenated aqueous solutions
27. Corrosion mechanism and process of hardware of disc suspension type Insulators on ±800 kV transmission lines10.1109/TDEI.2015.005208 ↗
28. Insulator selection for AC overhead lines with respect to contamination10.1109/TPWRD.2009.2024666 ↗
29. ANSI C29.2B, Insulator Pins and Pin Type Insulators- General Use and Applications, American National Standards Institute, New York, 1987.
30. ASTM A153/A153M-16ª, Standard Specification for Zinc Coating (Hot-Dip) on Iron and Steel Hardware, ASTM International, 2016, doi: 10.1520/A0153_A0153M-16A.10.1520/A0153_A0153M-16A ↗
31. Structural and microhardness changes after turning of the AISI 1045 steel for minimum quantity cooling lubrication10.1007/s11665-016-2450-4 ↗
32. On the influence of cyclic loadings on the magnetic permeability of ferritic-pearlitic AISI 1045 steel10.1016/j.ijfatigue.2021.106650 ↗
33. Effect of ultrasonic fog on AC flashover voltage of polluted porcelain and glass insulators10.1109/TDEI.2013.6508744 ↗
34. Understanding ozone formation at two Islands of Rio de Janeiro10.1016/j.apr.2017.10.003 ↗
35. Chapter 11 – Air Quality