Fracture of a compressor rotor made from grey cast iron
Source abstract
Abstract
Abstract In this study, the fracture of a compressor rotor manufactured from grey cast iron is investigated. In order to study the causes of the fracture, specimens prepared from the damaged rotor were subjected to experiments such as hardness and Charpy impact tests. The effect of microstructure on the fracture was also considered. Results showed that the rotor was manufactured from a cast iron containing carbon figures higher than values stated in standards and therefore it has a low impact energy. Geometrical analysis of the compressor rotor revealed that early failure of the structure started from a sharp corner radius by which stress concentrations are created in the rotor.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Mechanical Failure Analysis and Simulation · Fatigue and fracture mechanics · Engineering Structural Analysis Methods
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (3)
Show source-provided references
1. The high strain-rate fracture behaviors of gray iron under compressive loading10.1016/S0254-0584(01)00371-6 ↗
2. Effect of austempering heat treatment on fracture toughness of copper alloyed gray iron10.1016/S0254-0584(99)00213-8 ↗
3. Standard Specification for Gray Iron Castings, ASTM A48–94a. 1994. p. 16–20.