Failure analysis of tendon breakout on bottom slab of a pre-stressed concrete box gird bridge during construction
Source abstract
Abstract
Abstract There were several tendons breakout on bottom slabs happening during construction stage of continuous pre-stressed concrete bridges in recent years in China. The paper studies one case based on numerical simulation that happened on a 47 + 75 + 47 m continuous pre-stressed concrete rigidframe bridge. In this paper, both linear elastic and nonlinear inelastic analysis are developed, concrete and reinforcements stress levels before and after pre-stressed tendons stressed are compared, and the path of crack appearance are revealed by calculation. The effects of the incorrect arrangement of reinforcement during construction are also analyzed, which is proved not to be the leading reason of the failure. The outcomes of the finite element analysis indicate that oversize of the longitudinal prestressed tendons and unreasonable sizes of the bottom slab are the main reasons of the failure. Some advices to avoid similar accident are given for future design.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Response to Dynamic Loads · Concrete Corrosion and Durability
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (10)
Show source-provided references
1. Approach to crack problems of bottom plate of continuous rigid frame bridges
2. Wei LY, Shen XD, Xiao RC. Mechanism and prevention countermeasures of cracking for bottom slab in a continuous prestressed concrete box girder. In: Proceeding of national conference on bridge eingieering. Beijing: China Communications Press; 2006. p. 831–36 [in Chinese].
3. Analysis of accident of bursting crack in bottom slab of a continuous rigid-frame bridge
4. Hewson · 2003
5. ANSYS guide. ANSYS release 10.0. Houston: Swanson Analysis System; 2006.
6. Ministry of Communications of the People’s Republic of China. Code for design of highway reinforced concrete and prestressed concrete bridges and culverts (JTG D62–2004). 2004.
7. Ministry of Railways of the People’s Republic of China. Code for design on reinforced and prestressed concrete structure of railway bridge and culvert (TB10002.3-2005).
8. Ministry of Construction of the People’s Republic of China. Code for design of concrete structures (GB 50010–2002), 2002.
9. AASHTO. LRFD bridge design specifications. 3rd ed. Washington (DC): AASHTO; 2004.
10. BS5400. Steel, concrete and composite bridges, Part 4. code of practice for design of concrete bridges. London (UK); 1990.