journal article·2011-09

Prediction of ammonium salt deposition in hydroprocessing air cooler tubes

Guofu Ou, Haozhe Jin, Haoping Xie, Jing Cao, Jie Qiu

Engineering Failure Analysis· Volume 18· Issue 6
Publisher page

Abstract

Abstract Corrosion by wet ammonium salt is one of the main causes to the failure of reactor effluent air cooler (REAC) tubes. Based on a failure case, this paper presents the dynamic process of ammonium chloride (NH 4 Cl) deposition. A finite element method was used for the numerical simulation of the flow field, temperature field and concentration field to analysis this deposition process. The effect of velocity on ammonium salt deposition was also analyzed by the simulation. Based on the study, we suggest that the process of ammonium salt deposition may be affected by multi-physical field coupling. Higher temperature gradient exists between the fluid and the wall surface. As velocity increases, the amount of deposited salt reduces while the distance of the position with max amount to REAC inlet increases. Compared with actual failure instances, this method can be used effectively in predicting the relative severity of ammonium salt corrosion in REAC tubes.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Cyclone Separators and Fluid Dynamics · Aerosol Filtration and Electrostatic Precipitation · Nuclear Engineering Thermal-Hydraulics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (12)

Show source-provided references
1. A study of corrosion in hydroprocessing reactor effluent air cooler system. API RP 932-A; 2004.
2. Kapusta SD, Ooms AD, Fort WC, et al. Systematic approach to controlling fouling and corrosion in crude unit overheads and hydrotreater reactor effluents. Paper 535. Corrosion 01. NACE; 2001.
3. Design, materials, fabrication, operation, and inspection guidelines for corrosion control in hydroprocessing reactor effluent air cooler (REAC) system. API RP 932-B; 2004.
4. Mitigate failure for reactor effluent air coolers
5. Failure analysis and prediction of pipe due to the interaction between multiphase flow and structure10.1016/j.engfailanal.2009.01.002 ↗
6. Fluid-structure interaction mechanism and numerical simulation of elbow erosion failure10.3901/JME.2009.11.119 ↗
7. Acid salt corrosion in a hydrotreatment plant of a petroleum refinery10.1016/j.engfailanal.2007.11.014 ↗
8. Shargay CA, Jacobs GA, Price MA. Ammonium salt corrosion in hydrotreating unit stripper column overhead systems. Paper 392. Corrosion 99. NACE; 1999.
9. Turner J, Daniel F. Design of hydroprocessing effluent wash water systems. Paper 593. Corrosion 98. NACE; 1998.
10. Calculations estimate process stream depositions
11. Shargay CA et al. Design considerations to minimize ammonium chloride corrosion in hydrotreater reactors. Paper 543. Corrosion 01. NACE; 2001.
12. Sun Adan, Fan Deyuan. Prediction, monitoring, and control of ammonium chloride corrosion in refining processes. Paper 359. Corrosion 10. NACE; 2010.