Failure analysis and retrofitting of superheater tubes in utility boiler
Source abstract
Abstract
Abstract The extreme spray water mass flow rate deviation was observed to occur in the middle temperature superheater of Sahand 2 × 325 MW Power Plant utility boiler, which severely affected its economic performance and safe operation. Boilers operating in these conditions led to failure in superheater tubes at the same place for two consecutive times in a three year span. Thus, the failure analysis of superheater tubes by investigating the visual inspection, chemical, scale and creep analysis was carried out. The brittle failure occurred in the superheater tubes after the fuel was changed from natural gas to heavy oil. Failure analysis showed that tubes were suffering from long term overheating which was instigated by high spray water flow rate. In order to rectify the boiler operating conditions, some modifications were applied in the boiler unit 1 and operating parameters on this boiler were compared with boiler unit 2. The results showed that the 8.33% reduction in heating surface area corresponds to 52.84 and 17.80% reduction in spray water mass flow rate for capacities equal to 300 and 260 MW, respectively.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Coal Combustion and Slurry Processing · Fire dynamics and safety research · Thermochemical Biomass Conversion Processes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (14)
Show source-provided references
1. Port · 1991
2. Root cause failure analysis of a division wall superheater tube of a coal-fired power station10.1016/j.engfailanal.2010.05.005 ↗
3. Thermal load deviation model for superheater and reheater of a utility boiler10.1016/S1359-4311(99)00049-6 ↗
4. Creep failures of overheated boiler, superheater and reformer tubes10.1016/j.engfailanal.2004.03.001 ↗
5. Failure analysis and modeling of super heater tubes of a waste heat boiler thermally coupled in ammonia oxidation reactor10.1016/j.engfailanal.2012.06.012 ↗
6. Caustic corrosion in a boiler waterside tube: root cause and mechanism10.1016/j.engfailanal.2012.09.010 ↗
7. CFD modeling of a boiler’s tubes rupture10.1016/j.applthermaleng.2006.03.017 ↗
8. Failure probability and remaining life assessment of reheater tubes
9. Chinese Standard: GB/T 17107–1997.
10. Viswanathan · 1989
11. DL/T 773–2001, 2002; Spheroidization evaluation standard of 12Cr1MoV steel used in power plant.
12. Inherent creep strength and long term creep strength properties of ferritic steels10.1016/S0921-5093(97)00345-6 ↗
13. Klueh · 2004
14. William Short, 1979; Fuel economy handbook, NIFES Ltd., (2nd ed.), Graham and Trotman.