Failure investigation of brass heat exchanger tube
Source abstract
Abstract
Abstract Failure analysis was carried out on a brass tube that leaked during service in a heat exchanger. The leaked tube had numerous cracks. The service fluid at the tube side is cooling water, while it is lube oil at the shell side. Microscopic examinations and energy dispersive spectroscopic analyses were carried out on the brass tube to understand the root cause of the failure. Microscopic examination of the tube cross sections revealed that the cracks initiated from the areas that suffered corrosion attack at the internal surface. Chemical analyses indicated that the areas that suffered corrosion attack were depleted in zinc in comparison to the bulk of the alloy. The failure investigation suggested that the brass tube suffered dezincification and the failure of the tube was due to corrosion fatigue that initiated from the areas of dezincification.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Metallurgy and Material Science · Aluminum Alloys Composites Properties · Nanoporous metals and alloys
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (12)
Show source-provided references
1. Metallurgically influenced corrosion
2. Corrosion of copper and copper alloys
3. Selective dissolution of brass in salt water
4. Case study: corrosion failure of yellow brass tubing in radiator application10.1007/s11668-012-9561-5 ↗
5. A review of defects and failures in brass rods and related components10.1007/BF02715925 ↗
6. Effect of flow induced corrosion and erosion on failure of a tube heat exchanger10.1016/j.matdes.2009.06.025 ↗
7. Fontana · 1986
8. Corrosion fatigue failures
9. Failure analysis of the brass tubes in a lubricating oil cooler10.1016/j.engfailanal.2011.07.018 ↗
10. Failures of heat exchangers
11. Shrier · 1994 · vol. I, 3rd ed.
12. Development of brasses to resist dezincification10.1016/j.corsci.2006.06.024 ↗