Study on bolt head corrosion influence on the clamping force loss of high strength bolt
Source abstract
Abstract
Abstract High-strength bolts are widely used for connections in steel structures and the load-bearing capacity of such connections is very important for the safety of steel structures. However, numerous traces of corrosion have been observed around high-strength bolt joints of steel structures on site, which can affect the tightening force of these bolts and therefore reduce the bearing capacity of the bolt joints. In this study, the stock-removing machine was used to quantitatively simulate the corrosion of high strength bolt head and the fiber bragg grating sensors were used for obtaining the clamping forces of high strength bolts. Based on the results of numerical simulation and experiments, it is found that fiber bragg grating sensors are reliable and stable for monitoring the clamping forces of high strength bolts while they are installed at the proper location and the clamping forces of high strength bolts are significantly influenced by the bolt head corrosion. The formula for evaluate the clamping force of the high strength bolt with bolt head corrosion is proposed by this study.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Mechanical stress and fatigue analysis · Geotechnical Engineering and Underground Structures · Railway Engineering and Dynamics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (15)
Show source-provided references
1. B. Standard, Eurocode 3: Design of steel structures, BS EN 1993–1 1.
2. J. Yang, Relaxation in high-strength bolted connections with galvanized steel, Ph.D. thesis, University of Connecticut (1997).
3. Stress relaxation behavior at high-tension bolted connections of stainless-steel plates10.1115/1.1338481 ↗
4. Detection of bolt load loss in hybrid composite/metal bolted connections10.1016/j.engstruct.2004.02.008 ↗
5. Experimental analysis of bolted connections: snug versus preloaded bolts10.1061/(ASCE)0733-9445(1998)124:7(765) ↗
6. Review of bolted connection monitoring10.1155/2013/871213 ↗
7. Measurement of axial stress using mode-converted ultrasound10.1016/j.ndteint.2008.09.005 ↗
8. H. Yasui, K. Kawashima, Acoustoelastic measurement of bolt axial load with velocity ratio method, in: Proceedings of the 15th World Conference on Non-Destructive Testing, Rome, Italy, 2000, pp. 15–21.
9. Ultrasonic measurement of self-loosening in bolted joints
10. Experimental study on remaining strength of high strength bolted joint after corrosion
11. Clamping force loss of high-strength bolts as a result of bolt head corrosion damage: Experimental research a10.1016/j.engfailanal.2015.08.037 ↗
12. Failure analysis of connecting bolts used for anchoring streetlights of a mountain highway10.1016/j.engfailanal.2014.11.006 ↗
13. Fiber grating sensors10.1109/50.618377 ↗
14. Multiplexing fiber bragg grating sensors10.1080/01468039108201715 ↗
15. ABAQUS., Abaqus analysis user’s manual, version 6.7, Dassault Systemes Inc.