Sol–gel encapsulated glucose oxidase arrays based on a pH sensitive fluorescent dye
Source abstract
Abstract
Abstract Optical glucose oxidase (GOx) arrays based on pH sensitive fluorescent dye (2-(4-tolyl)-4-[4-(1,4,7,10-tetraoxa-13-azacyclopentadecyl)benzylidene]-5-oxazolone) (CPO) has been constructed. The arrays were prepared by spotting of CPO and GOx together with tetraethoxysilane (TEOS)/Chitosan (CHIT) mixture via a microarrayer. After optimization studies, analytical characterization of enzyme arrays were carried out. The fluorescence intensity of the system was linearly correlated to glucose concentration in the range of 1.0–30.0 mM (in potassium phosphate buffer; 2.5 mM at pH 7.0). Furthermore, the developed arrays were used to analyze glucose in some beverages and HPLC was used as a reference method for independent glucose analysis.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Analytical Chemistry and Sensors · Electrochemical sensors and biosensors · Advanced biosensing and bioanalysis techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (19)
Show source-provided references
1. Stable sol-gel microstructured and microfluidic networks for protein patterning10.1002/bit.1066 ↗
2. Fluorescence studies of crown ether complexes-solvent effects regarding the inclusion properties of host-guest sensor complexes10.1080/03067310500154221 ↗
3. Aging and drying of gels10.1016/0022-3093(88)90008-7 ↗
4. Apparent low surface areas in microporpus SiO2-xerogels10.1007/BF00486712 ↗
5. Immobilization and characterizationof sol-gel encapsulated acetylcholinesterase fiber-optic biosensor10.1016/S0003-2670(01)00853-4 ↗
6. The hydrolysis of 1,5-gluconolactone: semi-empirical methods and 13C NMR confirmation10.1016/0166-1280(92)85066-T ↗
7. Fluorescence sensing of glucose using glucose oxidase modified by PVA-pyrene prepared via “click” chemistry10.1021/bm900755y ↗
8. An optical glucose biosensor based on derived glucose oxidase immobilised onto a sol-gel matrix10.1016/S0925-4005(99)00083-0 ↗
9. Fluorometric sensors based on chemically modified enzymes: glucose determination in drinks10.1016/S0039-9140(03)00075-4 ↗
10. Direct determination of glucose in serum by fluorimetry using a labeled enzyme10.1016/S0003-2670(00)00831-X ↗
11. Fluorescence measurement of glucose by pyrene-modified oxidase10.1016/S1381-1177(02)00029-2 ↗
12. Sol-gel based glucose biosensors employing optical oxygen transducers, and a method for compensating for variable oxygen background10.1016/S0956-5663(99)00073-1 ↗
13. Haugland · 2002
14. Haugland · 2005
15. Photophysical properties of an on/off fluorescent pH indicator excitable with visible light based on a borondipyrromethene-linked phenol10.1016/j.jphotochem.2006.03.015 ↗
16. Synthesis and spectroscopic properties of new 5-oxazolone derivatives containing an N-phenyl-aza-15-crown-5 moiety10.1016/j.tetlet.2007.08.018 ↗
17. Immobilization of acethylcholinesterase on gold nanoparticles embedded in sol-gel film for amperometric detection of organophosphorous insecticide10.1016/j.bios.2007.03.008 ↗
18. Micro-structured devices for chemical sensing of flavor and fragrance10.1002/elsc.200720235 ↗
19. Photophysical characterization of fluorescent oxazol-5-one derivatives in PVC and their application as biosensors in the detection of ACh and AChE inhibitor: Donepezil10.1016/j.dyepig.2007.02.005 ↗