Isotropic conductive paste for bioresorbable electronics
Source abstract
Abstract
Bioresorbable implantable medical devices can be employed in versatile clinical scenarios that burden patients with complications and surgical removal of conventional devices. However, a shortage of suitable electricalinterconnection materials limits the development of bioresorbable electronic systems. Therefore, this study highlights a highly conductive, naturally resorbable paste exhibiting enhanced electrical conductivity and mechanical stability that can solve the existing problems of bioresorbable interconnections. Multifaceted experiments on electrical and physical properties were used to optimize the composition of pastes containing beeswax, submicron tungstenparticles, and glycofurol. These pastes embody isotropic conductive paths for three-dimensional interconnects and function as antennas, sensors, and contact pads for bioresorbable electronic devices. The degradation behavior in aqueous solutions was used to assess its stability and ability to retain electrical conductance (∼7 kS/m) and structural form over the requisite dissolution period. In vitro and in vivo biocompatibility tests clarified the safety of the paste as an implantable material.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Conducting polymers and applications · Advanced Sensor and Energy Harvesting Materials · Electrospun Nanofibers in Biomedical Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (90)
Show source-provided references
1. Dissolution chemistry and biocompatibility of silicon- and germanium-based semiconductors for transient electronics10.1021/acsami.5b02526 ↗
2. Transient light-emitting diodes constructed from semiconductors and transparent conductors that biodegrade under physiological conditions10.1002/adma.201902739 ↗
3. Dissolvable metals for transient electronics10.1002/adfm.201301847 ↗
4. Study of physically transient insulating materials as a potential platform for transient electronics and bioelectronics10.1002/adfm.201304186 ↗
5. A physically transient form of silicon electronics10.1126/science.1226325 ↗
6. Biodegradable materials for multilayer transient printed circuit boards10.1002/adma.201403164 ↗
7. Fully biodegradable microsupercapacitor for power storage in transient electronics10.1002/aenm.201700157 ↗
8. Materials for programmed, functional transformation in transient electronic systems
9. Wireless bioresorbable electronic system enables sustained nonpharmacological neuroregenerative therapy10.1038/s41591-018-0196-2 ↗
10. Transient, biocompatible electronics and energy harvesters based on ZnO10.1002/smll.201300146 ↗
11. A bioresorbable magnetically coupled system for low-frequency wireless power transfer10.1002/adfm.201905451 ↗
12. Wirelessly controlled, bioresorbable drug delivery device with active valves that exploit electrochemically triggered crevice corrosion10.1126/sciadv.abb1093 ↗
13. Bioresorbable silicon electronic sensors for the brain10.1038/nature16492 ↗
14. Biodegradable and flexible arterial-pulse sensor for the wireless monitoring of blood flow10.1038/s41551-018-0336-5 ↗
15. Stretchable, dynamic covalent polymers for soft, long-lived bioresorbable electronic stimulators designed to facilitate neuromuscular regeneration10.1038/s41467-020-19660-6 ↗
16. Flexible, sticky, and biodegradable wireless device for drug delivery to brain tumors10.1038/s41467-019-13198-y ↗
17. Bioresorbable optical sensor systems for monitoring of intracranial pressure and temperature10.1126/sciadv.aaw1899 ↗
18. Materials, mechanics designs, and bioresorbable multisensor platforms for pressure monitoring in the intracranial space
19. Synthesized biocompatible and conductive ink for 3D printing of flexible electronics10.1016/j.jmbbm.2020.103960 ↗
20. Electrospinning polyaniline-contained gelatin nanofibers for tissue engineering applications10.1016/j.biomaterials.2005.11.037 ↗
21. A novel electrically conductive and biodegradable composite made of polypyrrole nanoparticles and polylactide10.1016/j.biomaterials.2003.09.032 ↗
22. Fabrication and characterization of conductive poly (3,4-ethylenedioxythiophene) doped with hyaluronic acid/poly (l-lactic acid) composite film for biomedical application10.1016/j.jbiosc.2016.07.010 ↗
23. Biodegradable inkjet-printed electrochromic display for sustainable short-lifecycle electronics10.1039/D0TC04627B ↗
24. Impact of interconnection failure on photovoltaic module performance10.1002/pip.3401 ↗
25. Challenges in interconnection and packaging of microelectromechanical systems (MEMS)10.1109/ECTC.2000.853230 ↗
26. Conducting polymer-silk biocomposites for flexible and biodegradable electrochemical sensors10.1016/j.bios.2016.03.010 ↗
27. Biodegradable materials for multilayer transient printed circuit boards10.1002/adma.201403164 ↗
28. Metal microparticle – polymer composites as printable, bio/ecoresorbable conductive inks10.1016/j.mattod.2017.12.005 ↗
29. Natural wax for transient electronics10.1002/adfm.201801819 ↗
30. Laser sintering of Zn microparticles and its application in printable biodegradable electronics10.1002/aelm.201800693 ↗
31. Ultrasensitive wearable soft strain sensors of conductive, self-healing, and elastic hydrogels with synergistic “soft and hard” hybrid networks10.1021/acsami.7b07639 ↗
32. Room temperature electrochemical sintering of Zn microparticles and its use in printable conducting inks for bioresorbable electronics10.1002/adma.201702665 ↗
33. Biodegradable metallic glass for stretchable transient electronics10.1002/advs.202004029 ↗
34. Low-cost manufacturing of bioresorbable conductors by evaporation–condensation-mediated laser printing and sintering of Zn nanoparticles10.1002/adma.201700172 ↗
35. Maskless patterning of biodegradable conductors by selective laser sintering of microparticle inks and its application in flexible transient electronics10.1021/acsami.9b14431 ↗
36. Biodegradable piezoelectric force sensor10.1073/pnas.1710874115 ↗
37. Poly(lactic acid)-based ink for biodegradable printed electronics with conductivity enhanced through solvent aging
38. Routes towards manufacturing biodegradable electronics with polycaprolactone (PCL) via direct light writing and electroless plating
39. Comparison between field research and controlled laboratory research10.26502/acbr.50170011 ↗
40. Biodegradable molybdenum/polybutylene adipate terephthalate conductive paste for flexible and stretchable transient electronics
41. Dependence of electrical resistivity on temperature and Sn content in Pb-Sn solders
42. Tuning the electrical resistivity of conductive silver paste prepared by blending multi-morphologies and micro-nanometers silver powder10.1007/s10854-021-05954-y ↗
43. Biodegradable polyanhydrides as encapsulation layers for transient electronics10.1002/adfm.202000941 ↗
44. The use of tungsten as a chronically implanted material10.1088/1741-2552/aaa502 ↗
45. Degradation of tungsten coils implanted into the subclavian artery of New Zealand white rabbits is not associated with local or systemic toxicity10.1016/S0142-9612(02)00352-6 ↗
46. Biodegradation of tungsten embolisation coils used in children10.1007/s00247-002-0825-1 ↗
47. Tunneling conductivity in composites of attractive colloids
48. Tunneling conductivity and piezoresistivity of composites containing randomly dispersed conductive nano-platelets10.3390/ma7042501 ↗
49. Advances in conducting, biodegradable and biocompatible copolymers for biomedical applications10.3389/fmats.2019.00098 ↗
50. Recent advances in materials and flexible electronics for peripheral nerve interfaces10.1186/s42234-018-0007-6 ↗
51. Boongird · Biocompatibility study of glycofurol in rat brains · 2011 · 77
52. Microsphere preparation using the untoxic solvent glycofurol10.1007/s11095-010-0304-6 ↗
53. The nature of percolation ‘channels10.1016/0038-1098(73)90865-X ↗
54. Percolation and conduction10.1103/RevModPhys.45.574 ↗
55. Effect analysis of filler sizes on percolation threshold of isotropical conductive adhesives10.1016/j.compscitech.2006.05.017 ↗
56. The effect of particle size on electric conducting percolation threshold in polymer/conducting particle composites10.1023/A:1006774318019 ↗
57. A generalized criterion for rubber toughening: the critical matrix ligament thickness10.1002/app.1988.070350220 ↗
58. On the source of oscillatory behaviour during switching of power enhancement mode GaN HEMTs10.3390/en10030407 ↗
59. Role of interfacial charge transfer process in the graphene-ZnO-MoO3 core-shell nanoassemblies for efficient disinfection of industrial effluents10.2298/PAC1904376A ↗
60. Synthesis of Mo-doped WO 3 nanosheets with enhanced visible-light-driven photocatalytic properties10.1039/C5RA17098B ↗
61. Duffy · 2012 · 20
62. A review on nanofluid: preparation, stability, thermophysical properties, heat transfer characteristics and application10.1007/s42452-020-03427-1 ↗
63. Weil · 2013
64. Corrosion of tungsten microelectrodes used in neural recording applications10.1016/j.jneumeth.2011.03.012 ↗
65. The thermal properties of beeswaxes: unexpected findings10.1242/jeb.007583 ↗
66. Candelilla wax: prospective suitable applications within the food field10.1016/j.lwt.2022.113170 ↗
67. Crystal morphology in hydrocarbon systems10.1021/ie50689a009 ↗
68. Beeswax: a minireview of its antimicrobial activity and its application in medicine10.1016/j.apjtm.2016.07.003 ↗
69. Beeswax—composition and analysis10.1080/0005772X.1980.11097776 ↗
70. Surface wetting behavior of a WO 3 electrode under light-irradiated or potential-controlled conditions10.1021/jp901097b ↗
71. Interface energy and its influence on interface fracture between metal and ceramic thin films in nanoscale10.1063/1.3501090 ↗
72. Residual stress and surface energy of sputtered TiN films10.1007/s11665-015-1393-5 ↗
73. Wettability, adhesion, adsorption and interface tension in the polymer/surfactant aqueous solution system: II. Work of adhesion and adsorption of surfactant at polymer-solution and solution-air interfaces10.1016/j.colsurfa.2012.02.055 ↗
74. Effect of surface wettability on the interfacial adhesion of a thermosetting elastomer on glass10.1039/D1RA05916E ↗
75. International Organization for Standardization, Biological evaluation of medical devices — Part 12: Sample preparation and reference materials, ISO 10993-12:2021. 5 (2021) 1-21, https://www.iso.org/standard/75769.html, accessed January 04, 2023.
76. Mesenchymal stem cell-loaded porous tantalum integrated with biomimetic 3D collagen-based scaffold to repair large osteochondral defects in goats10.1186/s13287-019-1176-2 ↗
77. Graphene oxide-modified silk fibroin/nanohydroxyapatite scaffold loaded with urine-derived stem cells for immunomodulation and bone regeneration10.1186/s13287-021-02634-w ↗
78. Biomimetic electroconductive scaffolds for muscle regenerative engineering10.5185/amlett.2017.7106 ↗
79. Electrospun degradable polyesterurethane membranes: potential scaffolds for skeletal muscle tissue engineering10.1016/j.biomaterials.2004.11.035 ↗
80. Antioxidative study of Cerium Oxide nanoparticle functionalised PCL-Gelatin electrospun fibers for wound healing application
81. The antimicrobial activity of honey, bee pollen loads and beeswax from Slovakia10.2298/ABS1203927K ↗
82. The antimicrobial activity of some honey bee products and some Saudi folkloric plant extracts10.4197/Sci.23-2.4 ↗
83. Study of biodegradable properties of beeswax membrane in the focus of ectopic implantation
84. T-cell assays confirm immunogenicity of tungsten-induced erythropoietin aggregates associated with pure red cell aplasia10.1182/bloodadvances.2016001842 ↗
85. Tungsten accumulates in the intervertebral disc and vertebrae stimulating disc degeneration and upregulating markers of inflammation and pain10.22203/eCM.v041a33 ↗
86. An update to the toxicological profile for water-soluble and sparingly soluble tungsten substances10.3109/10408444.2014.1003422 ↗
87. Lassner · 1999
88. Pharmacokinetics of radiolabeled tungsten (188W) in male Sprague-Dawley rats following acute sodium tungstate inhalation10.3109/08958370902913237 ↗
89. Toxicological assessment of tungsten oxide nanoparticles in rats after acute oral exposure10.1007/s11356-017-8892-x ↗
90. Metal and metalloid multi-elementary ICP-MS validation in whole blood, plasma, urine and hair: reference values10.1016/j.forsciint.2005.04.020 ↗