Voltammetric sensor for tinidazole based on poly(carmine) film modified electrode and its application
Source abstract
Abstract
A poly(carmine) film-modified glassy carbon electrode (GCE) was fabricated and the electrochemical behavior of tinidazole at the modified electrode was investigated by electrochemical methods. A well-defined reduction peak was observed at 0.61 V and was applied for the determination of tinidazole. Compared with that at a bare GCE, the reduction peak potential of tinidazole shifted negatively and the reduction peak current increased significantly. The influences of some parameters on the reduction of tinidazole were also examined. Based on the experimental data, a possible mechanism was proposed for the electrochemical reaction of tinidazole at the modified electrode. It was found that the reduction peak current was proportional to the concentration of tinidazole in the range from 1.0 x 10(-7) to 5.0 x 10(-5)mol L(-1). The detection limit was about 1.0 x 10(-8)mol L(-1) after accumulation 90 s at a constant potential of 0.0 V. The proposed method was applied to determine tinidazole in drugs and the result was satisfied.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Electrochemical sensors and biosensors · Electrochemical Analysis and Applications · Analytical Chemistry and Sensors
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (18)
Show source-provided references
1. Shashank · Journal of the Indian Medical Association · 2003 · 101 · 329
2. Jadhav · Indian Pharmacist (New Delhi, India) · 2003 · 3 · 63
3. Sachan · Indian Journal of Pharmaceutical Sciences · 1999 · 61 · 301
4. Habel · Biomedical Chromatography · 1997 · 11 · 1610.1002/(SICI)1099-0801(199701)11:1<16::AID-BMC619>3.0.CO;2-K ↗
5. Jukka-Pekka · Journal of Pharmaceutical and Biomedical Analysis · 1996 · 14 · 126710.1016/S0731-7085(96)01768-2 ↗
6. Ali · Journal of Pharmaceutical and Biomedical Analysis · 1999 · 21 · 88110.1016/S0731-7085(99)00201-0 ↗
7. Yang · Analytical Science · 2004 · 20 · 82110.2116/analsci.20.821 ↗
8. Idel'nikov · Journal of Analytical Chemistry · 2005 · 60 · 50810.1007/s10809-005-0130-x ↗
9. Chen · Electrochimica Acta · 2003 · 48 · 404910.1016/S0013-4686(03)00562-0 ↗
10. Brett · Analytica Chimica Acta · 1999 · 385 · 11910.1016/S0003-2670(98)00808-3 ↗
11. Ensafi · Analytical Letters · 2003 · 36 · 59110.1081/AL-120018250 ↗
12. Wang · Talanta · 2000 · 51 · 56510.1016/S0039-9140(99)00315-X ↗
13. Li · Chemistry Letters · 2005 · 34 · 38610.1246/cl.2005.386 ↗
14. Persson · Journal of Electroanalytical Chemistry · 1992 · 326 · 115
15. Somasundrum · Journal of Chemical Society: Chemical Communication · 1993 · 115 · 162910.1039/c39930001629 ↗
16. Garcia-Gasca · Toxicology in Vitro · 2002 · 16 · 57310.1016/S0887-2333(02)00044-9 ↗
17. Zuman · Journal of Electroanalytical Chemistry · 1990 · 296 · 58910.1016/0022-0728(90)87275-O ↗
18. Lu · Talanta · 2004 · 63 · 65310.1016/j.talanta.2003.12.005 ↗