Effects of boride coating on wear behaviour of biomedical grade Ti–45Nb alloy
Source abstract
Abstract
Abstract This study investigates the tribological properties of as-received and borided Ti–45Nb alloys when paired with a WC-Co ball and examines the wear mechanisms that occur under dry sliding conditions. Pack boriding treatment applied to β type biomedical titanium alloy samples with improved structural and mechanical properties. The wear performance of both unborided and borided alloys, as well as the counterface and wear debris, were analysed using wear track measurements, weight loss techniques, and scanning electron microscopy. Unborided Ti–45Nb alloy underwent severe wear through multiple wear mechanisms, including tribo-chemical reactions, adhesion, and abrasive wear. Formation of a hard, bonded treatment layer on the Ti–45Nb alloy significantly enhanced its wear resistance up to certain load limits. In this case, mild polishing-type wear occurred, characterized by shallow scratches without weight loss. However, when the applied load exceeded the boriding layer’s load-carrying capacity, the surface layer was completely worn out by abrasive wear assisted delamination, and the alloy experienced severe wear resembling that of the unborided sample. Nevertheless, the volumetric wear rate is still 34 % lower than that of the unborided alloy. WC-Co ball was exposed to mild oxidative wear, particle detachment, abrasion, and micro-cracking wear mechanisms when rubbed against the harder boride layer.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Titanium Alloys Microstructure and Properties · Metal and Thin Film Mechanics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Naval Architecture and Marine Engineering , Karadeniz Technical University , Trabzon , Türkiye
Department of Mechanical Engineering , Karadeniz Technical University , Trabzon , Türkiye
References (39)
Show source-provided references
1. L. C. Zhang and L. Y. Chen, “A review on biomedical titanium alloys: recent progress and prospect,” Adv. Eng. Mater., vol. 21, no. 4, 2019, Art. no. 1801215, https://doi.org/10.1002/adem.201801215.10.1002/adem.201801215 ↗
2. P. Baskaran, B. Muthiah, and V. Uthirapathy, “A systematic review on biomaterials and their recent progress in biomedical applications: bone tissue engineering,” Rev. Inorg. Chem., 2025, https://doi.org/10.1515/revic-2024-0062.10.1515/revic-2024-0062 ↗
3. M. K. Gupta, et al.., “Tribological and surface morphological characteristics of titanium alloys: a review,” Arch. Civ. Mech. Eng., vol. 22, no. 2, 2022, Art. no. 72, https://doi.org/10.1007/s43452-022-00392-x.10.1007/s43452-022-00392-x ↗
4. Y. Chen, et al.., “A review of research on improving wear resistance of titanium alloys,” Coatings, vol. 14, no. 7, 2024, Art. no. 786, https://doi.org/10.3390/coatings14070786.10.3390/coatings14070786 ↗
5. G. Kara and G. Purcek, “Growth kinetics and mechanical characterization of boride layers formed on β-type Ti-45Nb alloy,” Surf. Coat. Technol., vol. 352, pp. 201–212, 2018, https://doi.org/10.1016/j.surfcoat.2018.07.085.10.1016/j.surfcoat.2018.07.085 ↗
6. G. Kara and G. Purcek, “Boriding behaviour of titanium alloys with different crystalline structures,” Surf. Eng., vol. 35, no. 7, pp. 1–7, 2018, https://doi.org/10.1080/02670844.2018.1552646.10.1080/02670844.2018.1552646 ↗
7. G. Efe, T. Yener, G. Ozcelik, and H. Ozkan, “TiB-based coating formation on Ti6Al4V alloy,” Mater. Test., vol. 66, no. 12, pp. 1965–1971, 2024, https://doi.org/10.1515/mt-2024-0076.10.1515/mt-2024-0076 ↗
8. K. Monisha, S. M. Shariff, A. Sekar, R. Raju, J. Manonmani, and J. Senthilselvan, “Titanium boride coating by high power diode laser alloying of amorphous boron with titanium and its surface property investigations,” Opt. Laser Technol., vol. 170, 2024, Art. no. 110159, https://doi.org/10.1016/j.optlastec.2023.110159.10.1016/j.optlastec.2023.110159 ↗
9. S. A. Kusmanov, “Improving the wear resistance of VT22 titanium alloy by anodic plasma electrolytic boriding,” Surf. Engin. Appl.Electrochem., vol. 57, no. 4, pp. 419–424, 2021, https://doi.org/10.3103/S1068375521040098.10.3103/S1068375521040098 ↗
10. G. Kara and G. Pürçek, “Characterization of boride layer formed on ti–6Al–4V alloy by electron beam evaporation technique,” Phys. Met. Metallogr., vol. 121, no. 14, pp. 1466–1472, 2020, https://doi.org/10.1134/S0031918X20140100.10.1134/S0031918X20140100 ↗
11. H. S. Hedia and N. Fouda, “Improved stress shielding on a cementless tibia tray using functionally graded material,” Mater. Test., vol. 55, nos. 11–12, pp. 845–851, 2013, https://doi.org/10.3139/120.110507.10.3139/120.110507 ↗
12. M. Geetha, A. K. Singh, R. Asokamani, and A. K. Gogia, “Ti based biomaterials, the ultimate choice for orthopaedic implants – a review,” Prog. Mater. Sci., vol. 54, no. 3, pp. 397–425, 2009, https://doi.org/10.1016/j.pmatsci.2008.06.004.10.1016/j.pmatsci.2008.06.004 ↗
13. J. Tardelli, C. Bolfarini, and A. Candido, “Comparative analysis of corrosion resistance between beta titanium and Ti-6A-4V alloys: a systematic review,” J. Trace Elem. Med. Biol., vol. 62, 2020, Art. no. 126618, https://doi.org/10.1016/j.jtemb.2020.10.1016/j.jtemb.2020.126618 ↗
14. B. Kucukyildirim and A. Eker, “Surface roughness changes on β-titanium orthodontic wires after corrosion in various artificial saliva solutions,” Mater. Test., vol. 55, no. 5, pp. 374–378, 2013, https://doi.org/10.3139/120.110542.10.3139/120.110542 ↗
15. K. Miura, N. Yamada, S. Hanada, T.-K. Jung, and E. Itoi, “The bone tissue compatibility of a new Ti–Nb–Sn alloy with a low Young’s modulus,” Acta Biomater., vol. 7, no. 5, pp. 2320–2326, 2011, https://doi.org/10.1016/j.actbio.2011.02.008.10.1016/j.actbio.2011.02.008 ↗
16. R. Godley, “Corrosion behaviour of a low modulus β–Ti–45Nb alloy for use in medi cal implants,” J. Mater. Sci-Mater. M, vol. 17, no. 1, pp. 63–67, 2006, https://doi.org/10.1007/s10856-006-6330-6.10.1007/s10856-006-6330-6 ↗
17. M. Delshadmanesh, G. Khatibi, M. Z. Ghomsheh, M. Lederer, M. Zehetbauer, and H. Danninger, “Influence of microstructure on fatigue of biocompatible β-phase Ti-45Nb,” Mater. Sci. Eng. A Struct. Mater., vol. 706, pp. 83–94, 2017, https://doi.org/10.1016/j.msea.2017.08.098.10.1016/j.msea.2017.08.098 ↗
18. A. Panigrahi, et al.., “Mechanical properties, structural and texture evolution of biocompatible Ti-45Nb alloy processed by severe plastic deformation,” J. Mech. Behav. Biomed. Mater., vol. 62, pp. 93–105, 2016, https://doi.org/10.1016/j.jmbbm.2016.04.042.10.1016/j.jmbbm.2016.04.042 ↗
19. N. A. A. Basry, H. Zuhailawati, and K. A. Shariff, “Bioactive surface modification of Ti–Nb alloy by alkaline treatment in potassium hydroxide solution,” Int. J. Mat. Res. (Z. Metallkd.), vol. 115, no. 10, pp. 804–820, 2024, https://doi.org/10.1515/ijmr-2023-0359.10.1515/ijmr-2023-0359 ↗
20. S. J. L. Sullivan and L. D. T. Topoleski, “Surface modifications for improved wear performance in artificial joints: a review,” J. Occup. Med., vol. 67, no. 11, pp. 2502–2517, 2015, https://doi.org/10.1007/s11837-015-1543-0.10.1007/s11837-015-1543-0 ↗
21. R. K. Roy and K. R. Lee, “Biomedical applications of diamond-like carbon coatings: a review,” J. Bio. Mat. Res. B: App. Bio., vol. 83, no. 1, pp. 72–84, 2007, https://doi.org/10.1002/jbm.b.30768.10.1002/jbm.b.30768 ↗
22. S. S. Jakobsen, et al.., “Failure of total hip implants: metals and metal release in 52 cases,” Cont. Dermat., vol. 71, no. 6, pp. 319–325, 2014, https://doi.org/10.1111/cod.12275.10.1111/cod.12275 ↗
23. F. Şenaslan, M. Taşdemir, A. Çelik, and Y. B. Bozkurt, “Enhanced wear resistance and surface properties of oxide film coating on biocompatible Ti45Nb alloy by anodization method,” Surf. Coat. Technol., vol. 469, 2023, Art. no. 129797, https://doi.org/10.1016/j.surfcoat.2023.129797.10.1016/j.surfcoat.2023.129797 ↗
24. İ. Hacısalihoğlu, G. Kaya, T. O. Ergüder, E. Mandev, E. Manay, and F. Yıldız, “Tribological and thermal properties of plasma nitrided Ti45Nb alloy,” Surf. Interfaces, vol. 22, 2021, Art. no. 100893, https://doi.org/10.1016/j.surfin.2020.100893.10.1016/j.surfin.2020.100893 ↗
25. O. Çomakli, “Influence of CrN, TiAlN monolayers and TiAlN/CrN multilayer ceramic films on structural, mechanical and tribological behavior of β-type Ti45Nb alloys,” Ceram. Int., vol. 46, no. 6, pp. 8185–8191, 2020, https://doi.org/10.1016/j.ceramint.2019.12.046.10.1016/j.ceramint.2019.12.046 ↗
26. M. Long and H. J. Rack, “Friction and surface behaviour of selected titanium alloys during reciprocating-sliding motion,” Wear, vol. 249, no. 1, pp. 157–167, 2001, https://doi.org/10.1016/S0043-1648(01)00517-8.10.1016/S0043-1648(01)00517-8 ↗
27. G. Straffelini and A. Molinari, “Dry sliding wear of Ti-6Al-4Valloy as influenced by the counterface and sliding conditions,” Wear, vol. 236, nos. 1–2, pp. 328–338, 1999, https://doi.org/10.1016/j.jmrt.2016.03.007.10.1016/S0043-1648(99)00292-6 ↗
28. A. Molinari, G. Straffelini, B. Tesi, and T. Bacci, “Dry sliding wear mechanisms of the Ti6Al4V alloy,” Wear, vol. 208, nos. 1–2, pp. 105–112, 1997, https://doi.org/10.1016/S0043-1648(96)07454-6.10.1016/S0043-1648(96)07454-6 ↗
29. K. Holmberg, Coatings Tribology: Properties, Mechanisms, Techniques and Applications in Surface Engineering, Amsterdam, Elsevier, 2009.
30. S. İ. Ayvaz, “Enhancing the wear performance of Ti–6Al–4V against Al2O3 and WC-6Co via TiBn layer produced by boriding,” Mater. Test., vol. 65, no. 2, pp. 279–290, 2023, https://doi.org/10.1515/mt-2022-0238.10.1515/mt-2022-0238 ↗
31. S. E. Kravchenko, D. Y. Kovalev, A. A. Vinokurov, N. N. Dremova, A. V. Ivanov, and S. P. Shilkin, “Synthesis and thermal oxidation stability of nanocrystalline niobium diboride,” Inorg. Mater., vol. 57, no. 10, pp. 1005–1014, 2021, https://doi.org/10.1134/S002016852110006X.10.1134/S002016852110006X ↗
32. B. Basu, G. B. Raju, and A. K. Suri, “Processing and properties of monolithic TiB2 based materials,” Int. Mater. Rev., vol. 51, no. 6, pp. 352–371, 2006, https://doi.org/10.1179/174328006X102529.10.1179/174328006X102529 ↗
33. G. Kara, G. Pürçek, Y. Atasoy, and E. Bacaksız, “Microstructure and tribological properties of Ti borided by electron beam evaporation technique,” J. Balk. Tribol. Assoc., vol. 21, no. 1, pp. 24–37, 2015.
34. L. A. Arteaga-Hernandez, C. A. Cuao-Moreu, C. E. Gonzalez-Rivera, M. Alvarez-Vera, J. A. Ortega-Saenz, and M. A. L. Hernandez-Rodriguez, “Study of boriding surface treatment in the tribological behavior of an AISI 316L stainless steel,” Wear, vol. 477, 2021, Art. no. 203825, https://doi.org/10.1016/j.wear.2021.203825.10.1016/j.wear.2021.203825 ↗
35. H. Engqvist, H. Högberg, G. A. Botton, S. Ederyd, and N. Axén, “Tribofilm formation on cemented carbides in dry sliding conformal contact,” Wear, vol. 239, no. 2, pp. 219–228, 2000, https://doi.org/10.1016/S0043-1648(00)00315-X.10.1016/S0043-1648(00)00315-X ↗
36. B. Basu and M. Kalin, Tribology of Ceramics and Composites A Materials Science Perspective, Hoboken, New Jersey, John Wiley & Sons, Inc, 2011.10.1002/9781118021668 ↗
37. Q. Zhang, H. Ding, G. Zhou, et al.., “Dry sliding wear behavior of a selected titanium alloy against counterface steel of different hardness levels,” Metall. Mater. Trans. A, vol. 50, no. 1, pp. 220–233, 2019, https://doi.org/10.1007/s11661-018-4993-5.10.1007/s11661-018-4993-5 ↗
38. J. T. Philip, B. Kuriachen, D. Kumar, and J. Mathew, “Tribo-behavioural transition of Ti6Al4V as a function of sliding velocity and load under dry sliding conditions,” Trib. Mat. Surf. Int., vol. 17, no. 2, pp. 99–118, 2023, https://doi.org/10.1080/17515831.2022.2139517.10.1080/17515831.2022.2139517 ↗
39. K. Adachi, K. Kato, “Formation of smooth wear surfaces on alumina ceramics by embedding and tribo-sintering of fine wear particles,” Wear, vol. 245, nos. 1–2, pp. 84–91, 2000, https://doi.org/10.1016/S0043-1648(00)00468-3.10.1016/S0043-1648(00)00468-3 ↗