Application of a high temperature chamber for X-ray stress analysis
Source abstract
Abstract
Abstract The adhesion strength as well as the crack resistance of hard CVD coatings on cutting tools are widely influenced by the appertaining residual stress states. They are generated during cooling down from coating temperature, or during a subsequent heat treatment. To enhance the knowledge of the residual stress development in such CVD coatings on steels, X-ray residual stress analyses were performed during the cooling process. Therefore, a high temperature chamber for a Ψ-diffractometer was developed and manufactured. It allows X-ray residual stress analyses at temperatures of up to at least 1000°C using a measuring range of 2θ ≥ 94° at |Ψ| ≤ 60°.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Metal and Thin Film Mechanics · Metal Alloys Wear and Properties · Fusion materials and technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Karlsruhe
References (13)
Show source-provided references
1. 1985
2. Coatings Tribology – Properties
3. 1995
4. 1997
5. Röntgenografische Untersuchung von Eigenspanungen in Werkstoffen10.1002/mawe.19950260310 ↗
6. Monochromateur par Rayons Röntgen
7. Parallel Beam Methods in Powder Diffraction and Texture in the Laboratory
8. Ω-Goniometer
9. Das sin2Ψ-Verfahren in der röntgenografischen Spannungsmessung
10. Ψ-Goniometer
11. 1995
12. 1966 · 1
13. Predicted Single-Crystal Elastic Constants of Stainless-Steel 316