This work proposes a digital methodology for producing patient-specific wrist immobilisation splint and evaluates form, fit and functional aspects of the fabricated splint by finite element analysis and post production performance testing. The upper limb of a volunteer is first scanned using a 3D scanner, then the data is reverse engineered to obtain a CAD model of the desired splint. Finally, A polyamide full-scale wrist splint is fabricated using selective laser sintering approach. Maximum von Mises stress and deflection developed during finite element analysis of CAD model are found 18.98 MPa and 0.68 mm respectively. The flexural and compressive strength of polyamide-PA2200 specimens have been found 67 MPa and 56 MPa respectively. In post production fitment test, splint is found conforming to anatomical shape, capable of providing adequate ventilation and performing intended task. Results show that the proposed methodology is technically feasible and has potential to be used as an alternative method of producing patient specific wrist immobilisation splint.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Prosthetics and Rehabilitation Robotics · Anatomy and Medical Technology · Total Knee Arthroplasty Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Mechanical Engineering, Jaypee University of Engineering and Technology, Guna, India

References (30)

Show source-provided references
1. 10.1097/00008526-199100340-0001210.1097/00008526-199100340-00012 ↗
2. 10.1080/10667857.2018.149193310.1080/10667857.2018.1491933 ↗
3. 10.1016/S0305-4179(03)00080-910.1016/S0305-4179(03)00080-9 ↗
4. 10.3402/meo.v20.2984710.3402/meo.v20.29847 ↗
5. 10.1007/s40430-018-1425-910.1007/s40430-018-1425-9 ↗
6. 10.1080/17452759.2010.52818310.1080/17452759.2010.528183 ↗
7. 10.1243/095441100153561510.1243/0954411001535615 ↗
8. 10.1080/17452759.2015.106998910.1080/17452759.2015.1069989 ↗
9. 10.15221/16.08810.15221/16.088 ↗
10. 10.1109/TBME.2007.91263810.1109/TBME.2007.912638 ↗
11. 10.1186/1743-0003-8-110.1186/1743-0003-8-1 ↗
12. 10.1097/JPO.0b013e31829be19c10.1097/JPO.0b013e31829be19c ↗
13. 10.1115/1.402775510.1115/1.4027755 ↗
14. 10.4015/S101623721650022810.4015/S1016237216500228 ↗
15. 10.1504/IJRAPIDM.2018.09580610.1504/IJRAPIDM.2018.095806 ↗
16. Juneja M · Addit Manuf · 2018 · 22 · 243
17. 10.1108/RPJ-05-2017-009910.1108/RPJ-05-2017-0099 ↗
18. 10.1080/17452759.2011.55858810.1080/17452759.2011.558588 ↗
19. 10.1177/175899831454480210.1177/1758998314544802 ↗
20. 10.1108/RPJ-03-2012-002710.1108/RPJ-03-2012-0027 ↗
21. 10.1007/s12206-015-1115-910.1007/s12206-015-1115-9 ↗
22. Kelly S · 2015 · 230
23. 10.1145/2858036.285834010.1145/2858036.2858340 ↗
24. Baronio G · Appl Bionics Biomech · 2016 · 201610.1155/2016/8347478 ↗
25. 10.1108/RPJ-12-2015-018710.1108/RPJ-12-2015-0187 ↗
26. 10.18502/keg.v2i2.60710.18502/keg.v2i2.607 ↗
27. 10.1016/j.rehab.2018.05.108910.1016/j.rehab.2018.05.1089 ↗
28. 10.1007/s10916-018-0909-610.1007/s10916-018-0909-6 ↗
29. Baumgartner DR, Baumgartner TJ, inventors. Low-temperature reusable thermoplastic splint. United States patent US 7,597,671. 2009.
30. Product Information, PA2200/PA2201, EOS GmbH. [cited 2020 Aug 2] Available from: https://www.eos.info/pa-2200-2201-da42d3327dfc8bf2.